PROFINET scanner for linking compatible rack-based RX3i remote I/O to a PROFINET IO controller. Verify the complete -BCB nameplate, installed firmware and project configuration together.
|
IC695PNS001 is the PACSystems RX3i PROFINET Scanner used to represent a compatible rack-based remote I/O station to a PROFINET IO controller. It allows supported RX3i I/O modules to operate in a remote rack while preserving the project's slot and subslot structure. Treat -BCB as part of the complete purchase identity. Before replacement, compare the nameplate, scanner firmware, PAC Machine Edition version, GSDML file, controller or PNC firmware, rack power supply and module layout; a matching base number or similar appearance alone does not confirm interchangeability. |
Purchase verification
Send the complete IC695PNS001-BCB nameplate, clear front and side photographs, installed firmware, rack and power-supply list, project software version, required quantity and destination. Myrtle will compare the requested scanner with the installed architecture before quotation. |
Values are restated from Emerson PACSystems RX3i documentation, including GFK-2714AN, GFK-3248K and the PACSystems RX3i System Manual. Final selection must follow the complete supplied-unit nameplate and installed revision.
| Model | IC695PNS001-BCB | Manufacturer | GE | |
| Product family | PACSystems RX3i | Product type | PROFINET Scanner module | |
| System role | Rack-based remote I/O device under a PROFINET IO controller | Revision scope | Bxxx family; verify the complete -BCB nameplate | |
| Serial module support | IC695CMM002/CMM004 support requires PNS Bxxx firmware 3.35 or later | Engineering software | PAC Machine Edition 10.00 or later for CMM002/CMM004 support | |
| Remote HART information | Supported on PNS Bxxx with firmware 3.10 or later | HART GSDML file | GSDML-V2.3-GEIP-RX3iPNS-20160602.xml for supported HART service options | |
| Backplane / power | Use combinations listed in the RX3i System Manual GFK-2314 | Country of origin | Verify the supplied-unit label | |
| Firmware / project check | Verify controller or PNC firmware, PNS firmware and PAC Machine Edition version | Device configuration | Preserve PROFINET device name, IP settings, slot and subslot map | |
| Rack documentation | Confirm rack power supply and installed module layout | Replacement identity | Use the complete IC695PNS001-BCB nameplate | |
| System documentation | GFK-2714AN, GFK-3248K and the applicable RX3i system manual | Selection note | Do not infer interchangeability from appearance alone | |
| Integration check | Confirm the GSDML file and feature compatibility before replacement | |||
|
Remote rack I/O
Connects compatible RX3i rack I/O to a PROFINET controller architecture. |
Plant modernization
Preserves documented slot mapping and firmware requirements during replacement planning. |
Process I/O
Provides a scanner point for supported standard and advanced rack-based I/O. |
Discrete automation
Supports remote I/O stations where diagnostic visibility and project consistency matter. |
|
Payment
T/T
|
Port
Xiamen
|
Delivery time
3–5 days
|
Condition
In stock
|
![]() |
What buyers should verify in the photos
Confirm that the label shows IC695PNS001-BCB. Review the connector or terminal layout, housing condition, revision marks and every supplied accessory. For an installed-system replacement, compare the photographed scanner, rack power supply and adjacent modules with the project hardware list and the unit being removed. Buyer tip: Request current front, side and nameplate photographs before stock confirmation.
|
|
Is IC695PNS001-BCB a like-for-like replacement for another IC695PNS001?
Not from the base number alone. Match the complete -BCB nameplate, scanner firmware, PAC Machine Edition version, GSDML file, rack power supply and slot/subslot configuration before removal. |
Can IC695PNS001-BCB support IC695CMM002 or IC695CMM004 serial modules in the remote rack?
Official compatibility tables list this support for PNS Bxxx firmware 3.35 or later; PAC Machine Edition 10.00 or later is required for engineering support. Confirm the controller and project versions as well. |
|
What is required if my project uses Remote Get HART Device Information?
For PNS Bxxx, the official minimum scanner firmware is 3.10. HART service options also require GSDML-V2.3-GEIP-RX3iPNS-20160602.xml; check the controller or PNC firmware listed for the same feature. |
What should I back up before replacing IC695PNS001-BCB?
Save the project and record the PROFINET device name, IP settings, GSDML revision, rack slot/subslot map, module revisions and firmware. Photograph the rack before disconnecting power or network cables. |
|
Why should I provide the full -BCB suffix when requesting a quotation?
Official compatibility tables separate scanner families. The complete -BCB identity helps avoid supplying a visually similar unit that does not match the installed firmware or engineering environment. |
What information will speed up verification and dispatch?
Send the full nameplate, front and side photos, current firmware, controller or PNC model, PAC Machine Edition version, GSDML file, rack and power-supply list, quantity and destination. |
PLCEXPORT supports maintenance, engineering and procurement teams sourcing industrial automation components. We review model identity, visible condition and delivery details before quotation.
Published product links are grouped by brand; this combination is arranged specifically for the IC695PNS001-BCB page.
|
Elrest CM211
|
Eaton XC-303
|
LS Electric XGB XEC
|
Panasonic FP7 CPS41E
|
|
AutomationDirect BRX BX-DM1E
|
Turck TBEN-L5-8DIP-8DOP
|
B&R X20CP0484
|
Beijer X2 control 15
|
|
ICP DAS XP-9188-IoT
|
Fatek FBs-32MCT2
|
Horner OCS HE-X10S
|
Lütze LOCC-Box-Net
|
|
Parker PAC320-CWB21-3X
|
Yaskawa MP3300iec
|
Nidec C200-044
|
Mitsubishi Alpha2 AL2-24MR-D
|
|
Schleicher XCx 300
|
Saia PCD3.M5560
|
Berghof C-PRO 13
|
KEB C6 COMPACT 2
|
|
DIRECT SALES SUPPORT · GE · PACSYSTEMS RX3I
Need a verified IC695PNS001-BCB for an installed RX3i system?
Send Myrtle the complete nameplate, scanner firmware, project version, rack configuration, clear product photographs, required quantity and destination. We will compare the requested scanner with the installed architecture before quotation.
|
|
Hot Tags: ge ic695pns001-bcb pacsystems rx3i profinet scanner module, China ge ic695pns001-bcb pacsystems rx3i profinet scanner module manufacturers, suppliers, GE Fanuc IC695CPE302, GE IC695CEP001, GE IC695CPE302, IC695CEP001 CEP Carrier Module, IC695CPE302, IC695CPE302 CPU module