51304907-200 SPC-II Smart Peripheral Controller I/O Board
This is the EC-version SPC-2 I/O board found in older Honeywell TDC 3000 supervisory assemblies. For replacement work, the useful clues are the full part number, revision mark, slot and cable arrangement-not appearance alone.
|
Part Number
51304907-200 |
Board Type
SPC-2 I/O Board EC |
System
TDC 3000 |
Documented Revision
EC version |
Where 51304907-200 fits in a Honeywell History Module
Honeywell service documentation identifies 51304907-200 as the SPC-2 Smart Peripheral Controller I/O Board EC. Within a TDC 3000 History Module, the associated SPC I/O board works with the SPC circuit board as part of the drive-communication hardware. 51304907-200 does not serve as a general-purpose process input or output card.
For replacement enquiries, compare the complete 51304907-200 number, EC revision, installed slot, connector position and companion SPC board. Clear close-up photographs of both board faces and cable orientation help confirm compatibility before shipment.
Match the board, revision and companion assembly
51304907-200 Technical Specifications
|
Manufacturer
|
Honeywell
|
|
Part Number
|
51304907-200
|
|
Board Type
|
SPC-2
|
|
Honeywell Description
|
Smart Peripheral Controller I/O Board EC
|
|
System Context
|
TDC 3000 History Module supervisory hardware
|
|
Documented Function
|
Associated SPC I/O board used with the SPC circuit board for communication with History Module drives
|
|
Hardware Revision
|
EC version
|
|
Service Manual Family
|
Honeywell Five/Ten-Slot Module Service and History Module Service
|
|
Replacement Check
|
Match part number, EC revision, slot, connectors and associated SPC hardware
|
|
Handling Requirement
|
Remove electronics-module power and use approved ESD protection before circuit-board service
|
Product identity follows Honeywell Five/Ten-Slot Module Service information. Functional and handling context follows Honeywell History Module Service documentation. Honeywell TDC/TPS overview

A difficult supervisory-hardware spare should not hold up a TDC 3000 recovery.
Looking for a difficult automation spare? Send the board code, revision, slot, host assembly and cable photos. Myrtle will help organize identification, availability and delivery for your maintenance schedule.
|
Sales manager
Myrtle |
Uses & Application Fields
|
History Module Link
Links the History Module peripheral-controller hardware with its companion interface and cable path. |
SPC-II Replacement
Supports like-for-like service when an installed Smart Peripheral Controller I/O board fails. |
Cable & Interface Service
Used when checking the SPC circuit board, associated SPC I/O board, drive cabling and host module as one service assembly. |
|
Oil, Gas & Refining
Installed-base TDC 3000 systems in continuous process plants and terminals. |
Chemical & Power
Legacy control-room and supervisory hardware supporting critical production assets. |
MRO & Obsolescence Support
Like-for-like sourcing for discontinued supervisory hardware and board-level repairs. |
51304907-200 FAQ
Answers below are limited to the board identity, History Module context and service precautions supported by Honeywell documentation.
What function does Honeywell 51304907-200 perform in a TDC 3000 History Module?
Honeywell documentation lists 51304907-200 as the SPC-2 Smart Peripheral Controller I/O Board EC. The associated SPC I/O board works with the SPC circuit board to communicate with History Module drives.
Why should the complete revision of 51304907-200 be checked before ordering?
Revision matching reduces the risk of receiving a board that does not suit the installed slot, connectors or companion SPC hardware. The -200 suffix identifies the documented EC version.
How does 51304907-200 work with the SPC circuit board?
Within the History Module, the SPC circuit board and associated SPC I/O board form part of the drive-communication hardware. Correct cabling and board pairing are required for the installed configuration.
Can Honeywell 51304907-200 be removed while the electronics module remains powered?
No. Honeywell History Module service instructions require electronics-module power to be removed before circuit-board replacement. ESD grounding and protected handling are also required.
Does 51304907-200 connect directly to field sensors or actuators?
No. 51304907-200 belongs to History Module supervisory hardware and supports the internal drive-communication path. Direct process signals are handled by dedicated TDC 3000 process I/O hardware.
Which details help confirm 51304907-200 compatibility before quotation?
Provide clear photos of both board faces, the complete 51304907-200 label, revision markings, installed slot, connector orientation, companion SPC board number, quantity and destination.
Recommended Models
Twenty linked models are selected from two website brands only. The final group collects ten additional automation references.
ABB
Allen-Bradley
Other Recommended Brands
|
Pilz PNOZ m B1 Safety Controller
|
Bachmann MX213 CPU Module
|
|
Saia PCD3.M5540 Controller
|
Eberle PLS 511S PLC Processor
|
|
Selectron CPU 752 Control Module
|
Lauer PCS 900 Operator Panel
|
|
Berghof C-PM Controller
|
Schleicher UST21 PLC Module
|
|
Festo CPX-CEC Motion Controller
|
KEB 00F5 Series Control Board
|
|
PEOPLE BEHIND THE PART NUMBERS
About PLCexportPLCexport supports industrial teams sourcing PLC, DCS, burner-management, turbine-control and safety-system spares. We check model details, organize availability and prepare international delivery options for maintenance and project teams. Part-number focused
Clear identification before quotation Worldwide support
TALK TO OUR SALES TEAM >Secure packing and international delivery |
![]() |
Hot Tags: honeywell 51304907-200 spc-ii smart peripheral controller i/o boardhoneywell 51304907-200 spc-ii smart peripheral controller i/o board, China honeywell 51304907-200 spc-ii smart peripheral controller i/o boardhoneywell 51304907-200 spc-ii smart peripheral controller i/o board manufacturers, suppliers