ABB TU849 Dual-Power Single-I/O TB840/TB840A Termination Unit

ABB TU849 Dual-Power Single-I/O TB840/TB840A Termination Unit

ABB · S800 I/O · MODULE TERMINATION UNIT
TU849 · TB840/TB840A MTU for Single I/O
ABB TU849 is a passive dual-power module termination unit for a redundant TB840/TB840A Optical ModuleBus Modem configuration serving single I/O. It provides two power inputs, one electrical ModuleBus and a rotary cluster-address switch.
Brand-new originalMOQ 1One-year warranty3–5 days
SALES SUPPORT
Myrtle · Stock 10 · MOQ 1
Send Inquiry
Description
TECHNICAL DATA
Technical Specifications
SERIES / FUNCTION
S800 I/O · redundant TB840/TB840A MTU
ARTICLE NUMBER
3BSE042560R1
I/O ARRANGEMENT
Single I/O; dual power
MODULEBUS
Single electrical ModuleBus; line redundancy
MODEM POSITIONS
Two TB840/TB840A positions
POWER INPUT
Two 24 V DC supplies (19.2–30 V)
CLUSTER ADDRESS
Rotary switch, 1–7
MECHANICAL KEYING
Four keys; 36 configurations
INSULATION / TEST
50 V rated insulation; 500 V AC dielectric test
SIZE / WEIGHT
124 × 186.5 × 47 mm; 0.45 kg
Reference: ABB S800 I/O communication-interface data. Confirm the installed TB840/TB840A or CI840/CI840A configuration, power arrangement and address setting before replacement.
CONTACT
Confirm ABB TU849 Before Ordering
Send the complete code, installed communication modules and required quantity for a configuration check.
SALES CONTACT
Myrtle
WHATSAPP
PRODUCT DETAILS
Product Image Display
TU849 new
ABB product image for TU849, article 3BSE042560R1.
Confirm single I/O with dual power
TU849 is for a redundant TB840/TB840A modem pair serving non-redundant I/O, while retaining individual power inputs for the two modems.
Trace one electrical ModuleBus
Unlike TU848, TU849 has a single electrical ModuleBus. Confirm the existing wiring before moving a connector.
Restore the cluster address
The cluster-address rotary switch is set from 1 to 7. Record the current value before replacement.
Keep the two modem positions identified
Before disconnecting anything, label the installed TB840/TB840A positions and photograph the terminal area. That simple check helps return each lead to the same modem after replacement.
Recheck each separate power input
TU849 retains individual power inputs for the two modems. Compare supply polarity and terminal markings with the cabinet wiring before energising the redundant pair.
Replacement Checks Before Shutdown
Distinguish TU849 from TU848
Both units use TB840/TB840A and dual power, but TU849 is for single I/O with one electrical ModuleBus. TU848 is for redundant I/O with a double ModuleBus.
Identify both 24 V DC supplies
TU849 has separate 19.2–30 V DC supply connections for each modem. Label both feeds before removal.
Trace the single ModuleBus connection
Record the single electrical ModuleBus path and do not transfer a double-ModuleBus wiring plan from a TU848 installation.
Check latch, keying and address
Set the mechanical keys to the installed configuration, lock the MTU to the DIN rail and restore the cluster address from 1 to 7.
TECHNICAL ANSWERS
Frequently Asked Questions
How does ABB TU849 differ from TU848 in a redundant TB840/TB840A station?
Both are dual-power MTUs for TB840/TB840A. ABB TU849 serves single I/O and has a single electrical ModuleBus; TU848 serves redundant I/O and has a double electrical ModuleBus.
Why does ABB TU849 need two power connections when it has one ModuleBus?
The two power connections supply the two TB840/TB840A modems individually. The I/O connection remains a single electrical ModuleBus, which is why the existing topology must be matched carefully.
What address must be copied when replacing ABB TU849?
TU849 has a rotary switch for the cluster address, with values 1–7. Record the existing setting before shutdown and restore it during installation.
Can ABB TU849 be hot-swapped?
No. ABB lists Hot Swap as not available. Replace the unit using the approved shutdown and reconfiguration procedure.
What cable and terminal checks apply to ABB TU849?
ABB lists solid or stranded wires from 0.2–2.5 mm² (24–12 AWG) and a recommended 0.5 Nm torque. Check the installed wiring and terminal labels before transfer.
What environmental conditions are listed for ABB TU849?
ABB specifies 0–55 °C operation, with approvals issued for +5 to +55 °C, IP20 protection and 5–95% non-condensing relative humidity.
Order Information
CONDITION
Brand-new original
MINIMUM ORDER
1 piece
WARRANTY
One year
HANDLING TIME
3–5 days
STOCK REFERENCE
10 units
SHIPPING PORT
Xiamen
ABOUT PLCEXPORT
Coordinated support from quotation to dispatch
Our sales, sourcing and operations teams review the requested order code, quantity and destination details together. Send the installed S800 I/O configuration so the request can be checked before replacement.
PLCEXPORT coordinated service team
Coordinated service support
Sales, sourcing and operations work from the same order-code and destination details.
PLCEXPORT warehouse verification
Warehouse label verification
Product labels and package details are checked before dispatch planning.
PLCEXPORT configuration review
Configuration review
Share installed-module details so the request can be checked before replacement.
PLCEXPORT supply coordination
Global supply coordination
Availability, commercial terms and destination information are coordinated for the requested item.
RELATED REFERENCES
Recommended Models
PLCEXPORT product links are grouped by brand for related maintenance searches. Confirm the exact installed system and full article number before selecting an alternative.
Other PLC & DCS Brands
Less-common controller and I/O references for maintenance searches; no external links are applied.
Opto 22
Opto 22 GRV-R7-MM1001-10
Opto 22 GRV-R7-MM2001-10
Opto 22 SNAP-PAC-S1
Opto 22 SNAP-PAC-S2
Bachmann
Bachmann MX213
Bachmann MX220
Bachmann MX230
Bachmann CNT204
Renu Electronics
Renu Electronics FIOA-0402-U
Renu Electronics FIOA-0800-L
Renu Electronics FIOA-0800-R
Renu Electronics FIOD-EN
ODOT
ODOT CN-8032-L
ODOT CT-121F
ODOT CT-3168
ODOT CT-4234
ICP DAS
ICP DAS I-7017
ICP DAS I-7055
ICP DAS I-7088
ICP DAS I-7188
WECON
WECON LX3V-0808MR-A2
WECON LX3V-0808MT-A2
WECON LX3V-1616MR-A2
WECON LX3V-1616MT-A2
Koyo DirectLOGIC
Koyo DL06-06AR
Koyo DL06-06DR
Koyo DL06-10AR
Koyo DL06-10DR
Horner
Horner HE-XC1E0
Horner HE-XC1E1
Horner HE-XC1E2
Horner HE-XC1E3

Hot Tags: abb tu849 dual-power single-i/o tb840/tb840a termination unit, China abb tu849 dual-power single-i/o tb840/tb840a termination unit manufacturers, suppliers, 3BSE076939R1, abb advant 800xa, ABB CI560 3BUC980002R1 TRIO Interface Submodule Advant 800xA, ABB PM866AK01, ABB PM866AK01 3BSE076939R1, PM866AK01 3BSE076939R1

Send Inquiry