TECHNICAL DATA
Technical Specifications
SERIES / FUNCTION
S800 I/O · redundant TB840/TB840A MTU
ARTICLE NUMBER
3BSE042558R1
I/O ARRANGEMENT
Redundant I/O; dual power
MODULEBUS
Double electrical ModuleBus; line redundancy
MODEM POSITIONS
Two TB840/TB840A positions
POWER INPUT
Two 24 V DC supplies (19.2–30 V)
CLUSTER ADDRESS
Rotary switch, 1–7
MECHANICAL KEYING
Two keys; 36 configurations
INSULATION / TEST
50 V rated insulation; 500 V AC dielectric test
SIZE / WEIGHT
124 × 186.5 × 47 mm; 0.45 kg
Reference: ABB S800 I/O communication-interface data. Confirm the installed TB840/TB840A or CI840/CI840A configuration, power arrangement and address setting before replacement.
CONTACT
Confirm ABB TU848 Before Ordering
Send the complete code, installed communication modules and required quantity for a configuration check.
PRODUCT DETAILS
Product Image Display
CONFIGURATION REFERENCE

Confirm redundant I/O and dual power
TU848 is the TB840/TB840A MTU for redundant I/O with one power input for each modem. Verify both supplies before replacement.
Trace the double ModuleBus
ABB specifies a double electrical ModuleBus for TU848. Both bus paths must be identified and returned to the correct terminals.
Restore the cluster address
The cluster rotary switch is set from 1 to 7. Capture the installed setting before any wiring is disturbed.
Check both modem positions before removal
Mark the installed TB840/TB840A positions and keep the redundant pair together. This avoids swapping the two sides while cables and power feeds are being reconnected.
Recheck each power connection
TU848 keeps separate power inputs for the two modems. Before startup, compare the terminal markings and supply connections with the existing cabinet wiring.
Replacement Checks Before Shutdown
Separate TU848 from TU849
TU848 connects redundant TB840/TB840A modems to redundant I/O and has double ModuleBus wiring. TU849 is the single-I/O version.
Verify both 24 V DC supplies
TU848 provides an individual power supply connection for each modem. Check both 19.2–30 V DC feeds and their labels before transfer.
Trace both ModuleBus paths
The unit has a double electrical ModuleBus. Do not cross-connect the two paths when replacing the termination unit.
Check cluster and key configuration
Record the rotary address (1–7) and verify the two mechanical-key positions. ABB lists 36 possible key combinations.
TECHNICAL ANSWERS
Frequently Asked Questions
When is ABB TU848 required instead of TU849?
ABB TU848 is used when a redundant TB840/TB840A modem configuration serves redundant I/O. TU849 is for single I/O, so the installed I/O redundancy must be identified before ordering.
How are the two power feeds used on ABB TU848?
TU848 has two 24 V DC power-supply connections, one for each modem, with a listed input range of 19.2–30 V DC. Both feeds must be matched during replacement.
Does ABB TU848 use one or two electrical ModuleBus paths?
ABB specifies a double electrical ModuleBus for TU848. The two paths support the redundant I/O arrangement and must be traced independently before cable transfer.
What cluster-address setting applies to ABB TU848?
TU848 uses one rotary switch for a cluster address from 1 to 7. Record the current setting before shutdown and restore it before operation.
Can ABB TU848 be hot-swapped?
No. ABB lists Hot Swap as not available for TU848. Carry out the work under the approved shutdown procedure.
What dimensions and operating conditions apply to ABB TU848?
ABB lists 124 × 186.5 × 47 mm, 0.45 kg, 0–55 °C operating temperature, IP20 protection and 5–95% relative humidity without condensation.
Order Information
CONDITION
Brand-new original
MINIMUM ORDER
1 piece
WARRANTY
One year
HANDLING TIME
3–5 days
STOCK REFERENCE
10 units
SHIPPING PORT
Xiamen
ABOUT PLCEXPORT
Coordinated support from quotation to dispatch
Our sales, sourcing and operations teams review the requested order code, quantity and destination details together. Send the installed S800 I/O configuration so the request can be checked before replacement.
RELATED REFERENCES
Recommended Models
PLCEXPORT product links are grouped by brand for related maintenance searches. Confirm the exact installed system and full article number before selecting an alternative.
GE Product References
Bently Nevada Product References
Other PLC & DCS Brands
Less-common controller and I/O references for maintenance searches; no external links are applied.
Crouzet
Crouzet em4 88 124 141
Crouzet em4 88 124 151
Crouzet em4 88 124 161
Crouzet em4 88 124 171
Berghof
Berghof ECC DIO 8
Berghof ECC AIO 16
Berghof ECC CNT 16
Berghof EC1000-0002
Koyo DirectLOGIC
Koyo DL205 D2-08ND3
Koyo DL205 D2-08TA
Koyo DL205 D2-16NA
Koyo DL205 D2-16TA
SIGMATEK
SIGMATEK DI 161
SIGMATEK DO 162
SIGMATEK AI 031
SIGMATEK AO 031
Fatek
Fatek FBs-14MA2-AC
Fatek FBs-24MA2-AC
Fatek FBs-40MA2-AC
Fatek FBs-60MA2-AC
Horner
Horner HE-XE1E4
Horner HE-XE1E5
Horner HE-XE2A
Horner HE-XE2R
Unitronics
Unitronics V350-35-TR20
Unitronics V560-57-T20B
Unitronics V700-T38
Unitronics USP-TCP
Haiwell
Haiwell H16S0P-e
Haiwell H16S2P-e
Haiwell H24S0R-e
Haiwell H24S0T-e
Hot Tags: abb tu848 dual-power redundant tb840/tb840a termination unit, China abb tu848 dual-power redundant tb840/tb840a termination unit manufacturers, suppliers, 3BSE076939R1, abb advant 800xa, ABB CI560 3BUC980002R1 TRIO Interface Submodule Advant 800xA, ABB PM866AK01, ABB PM866AK01 3BSE076939R1, PM866AK01 3BSE076939R1