TECHNICAL DATA
Technical Specifications
SERIES / FUNCTION
S800 I/O · redundant CI840/CI840A MTU
ARTICLE NUMBER
3BSE022462R1
I/O ARRANGEMENT
Redundant CI840/CI840A; single I/O
COMMUNICATION
PROFIBUS DP-V1; two DSUB9 connectors
SERVICE PORTS
Two RJ45 service-tool connections
POWER INPUT
24 V DC (19.2–30 V)
STATION ADDRESS
Two rotary switches, 0–99
MODULEBUS
Electrical ModuleBus; TB842 via TB806
MOUNTING
Vertical or horizontal DIN rail
SIZE / WEIGHT
124 × 186 × 47 mm; 0.50 kg
Reference: ABB S800 I/O communication-interface data. Confirm the installed TB840/TB840A or CI840/CI840A configuration, power arrangement and address setting before replacement.
CONTACT
Confirm ABB TU847 Before Ordering
Send the complete code, installed communication modules and required quantity for a configuration check.
PRODUCT DETAILS
Product Image Display
ABB product image for TU847, article 3BSE022462R1.
Identify the CI840/CI840A MTU
TU847 is for redundant CI840/CI840A field communication interfaces with single I/O; it is not a TB840/TB840A modem termination unit.
Trace both PROFIBUS and service ports
ABB specifies two PROFIBUS DSUB9 connectors and two RJ45 service-tool connections. Match each connection before cable transfer.
Record station addressing
Two rotary switches provide station addresses 0–99. Record the installed address before removing the TU847.
Keep the communication cables labelled
Label the two PROFIBUS plugs and the service-tool connections before removal. Reconnecting each cable to its original port avoids unnecessary commissioning checks.
Check the installed CI840/CI840A pair
Confirm the existing interface pair and the station address on both sides before fitting the termination unit back into the S800 I/O assembly.
Replacement Checks Before Shutdown
Confirm CI840/CI840A, not TB840/TB840A
TU847 is the MTU for redundant CI840/CI840A. Do not replace a TB840/TB840A termination unit with TU847 solely because the form factor appears similar.
Copy both station-address switches
The two rotary switches set the station address from 0 to 99. Document their values before removal and restore them before commissioning.
Trace both PROFIBUS links
TU847 has two PROFIBUS DSUB9 connectors. Identify cable direction and termination arrangement before disconnecting either connector.
Plan a powered-down intervention
ABB lists Hot Swap as not available. Follow the approved shutdown procedure before changing the MTU or its field communication interfaces.
TECHNICAL ANSWERS
Frequently Asked Questions
Which field communication interfaces are installed on ABB TU847?
ABB TU847 is designed for a redundant pair of CI840/CI840A field communication interfaces in a single-I/O configuration. It provides two positions for those communication interfaces.
How must the PROFIBUS wiring be checked on ABB TU847 before replacement?
TU847 provides two PROFIBUS DSUB9 connections. Label both cables and verify the installed termination arrangement before they are removed, because the two connections form part of the redundant field communication setup.
What station-address settings are used by ABB TU847?
TU847 has two rotary switches for the station address, with values from 0 to 99. Record the exact installed setting before replacement and restore it before startup.
Can an ABB TU847 be replaced while powered?
No. ABB lists Hot Swap as not available for TU847. The unit should be changed under the approved shutdown procedure.
How is a TB842 Optical ModuleBus Port connected to ABB TU847?
ABB specifies that a TB842 ModuleBus Optical Port can be connected to TU847 through TB806. Confirm that installed accessory before ordering or moving the ModuleBus wiring.
What physical requirements should be checked for ABB TU847?
ABB specifies vertical or horizontal DIN-rail mounting, 124 × 186 × 47 mm dimensions and approximately 0.50 kg weight. It also lists four mechanical keys with 36 possible configurations.
Order Information
CONDITION
Brand-new original
MINIMUM ORDER
1 piece
WARRANTY
One year
HANDLING TIME
3–5 days
STOCK REFERENCE
10 units
SHIPPING PORT
Xiamen
ABOUT PLCEXPORT
Coordinated support from quotation to dispatch
Our sales, sourcing and operations teams review the requested order code, quantity and destination details together. Send the installed S800 I/O configuration so the request can be checked before replacement.
RELATED REFERENCES
Recommended Models
PLCEXPORT product links are grouped by brand for related maintenance searches. Confirm the exact installed system and full article number before selecting an alternative.
GE Product References
Bently Nevada Product References
Other PLC & DCS Brands
Less-common controller and I/O references for maintenance searches; no external links are applied.
Opto 22
Opto 22 GRV-EPIC-PR1
Opto 22 GRV-EPIC-PR2
Opto 22 SNAP-PAC-R1
Opto 22 SNAP-PAC-R2
Bachmann
Bachmann MC206
Bachmann MC212
Bachmann MC220
Bachmann MX207
Renu Electronics
Renu Electronics FL004-V2
Renu Electronics FL005-V2
Renu Electronics FL055-V2
Renu Electronics FL100-S1
ODOT
ODOT PLC-C3351
ODOT B2341
ODOT C4374
ODOT CP-9131
ICP DAS
ICP DAS LP-5231
ICP DAS WP-2241-CE7
ICP DAS LP-2241
ICP DAS WP-5000
WECON
WECON LX3V-1410MR-A2
WECON LX3V-1410MT-A2
WECON LX3V-0806MR-A2
WECON LX3V-0806MT-A2
Koyo DirectLOGIC
Koyo DL105 D0-06DD1
Koyo DL105 D0-06DR
Koyo DL105 D0-08ND3
Koyo DL105 D0-08TA
Horner
Horner HE-XE1E0
Horner HE-XE1E1
Horner HE-XE1E2
Horner HE-XE1E3
Hot Tags: abb tu847 redundant ci840/ci840a termination unit, China abb tu847 redundant ci840/ci840a termination unit manufacturers, suppliers, 3BSE076939R1, abb advant 800xa, ABB CI560 3BUC980002R1 TRIO Interface Submodule Advant 800xA, ABB PM866AK01, ABB PM866AK01 3BSE076939R1, PM866AK01 3BSE076939R1