15.0 Ah auxiliary battery module that extends memory backup time for compatible IC693 and IC697 PLCs through the specified two-pin battery connection.
What matters when specifying IC693ACC302
15.0 Ah capacityDesigned for extended memory retention during prolonged controller power loss. |
Documented legacy supportUse only with the supported controller and power-supply models listed in GFK-2124. |
Two-pin leadUses a 0.6 m red/black 24 AWG lead with a female two-pin connector. |
Service-date disciplineRecord installation date and battery condition so retention planning is auditable. |
Description and purpose
|
IC693ACC302 is an auxiliary battery module for extending memory backup on compatible GE Series 90-30 and Series 90-70 controllers. Official product information specifies a 15.0 Ah battery in a flame-retardant ABS enclosure with a 0.6 m red-and-black lead and female two-pin connector. The accessory is intended to support battery-backed controller memory during long power interruptions; it does not replace a verified program backup. Installation must follow the controller procedure so memory is not lost while the existing battery is disconnected. Confirm the CPU or power-supply battery connector, polarity, battery age and storage history before service. |
Purchase verificationSend the controller CPU and power-supply models, current battery connection, full IC693ACC302 label, storage history if known, required quantity and destination. We will confirm the connector and handling requirements before quotation. |
Technical specifications
Values restated from GE Fanuc Auxiliary Battery Module IC693ACC302 data sheet GFK-2124. Confirm the complete supplied-unit nameplate and applicable revision before final selection.
Planning a IC693ACC302 replacement or new installation?
Send the controller CPU and power-supply models, current battery connection, full IC693ACC302 label, storage history if known, required quantity and destination. We will confirm the connector and handling requirements before quotation.
Sales Manager: MyrtleCompatibility review before quotationApplications
Maintains battery-backed memory through planned or unexpected long power outages.
Supports compatible Series 90-30 and Series 90-70 controller batteries.
Adds retention margin during plant outages and equipment storage.
Provides a documented replacement point when battery age is approaching the maintenance limit.
Ordering information
T/T
Xiamen
3–5 days
In stock
Product image and identification notes

What buyers should verify in the photos
Use clear front, side and connector views to confirm the complete IC693ACC302 identity, suffix, revision, terminal or port arrangement, housing condition and installed accessories.
For an installed-system replacement, compare the photographed unit with the project hardware catalog and the component being removed. Appearance alone does not prove interchangeability.
FAQ about IC693ACC302
Can IC693ACC302 replace the need for an offline program backup?
No. It extends battery-backed memory retention but cannot substitute for a validated project and configuration backup. Keep both protections in place.
How do I know whether IC693ACC302 fits my controller?
Check whether the installed IC693 power supply or IC697 CPU uses the supported two-pin battery connector. Send the controller and power-supply labels for confirmation.
How can I replace the battery without losing memory?
Follow the controller manual exactly, maintain the required temporary power or battery connection and prepare a verified backup first. Do not disconnect the existing battery casually.
How long will IC693ACC302 retain memory?
Official documentation gives controller-specific retention examples under stated conditions. Treat them as planning examples, not guarantees: actual time depends on the supported CPU, temperature, storage history and battery age.
What should I inspect when IC693ACC302 arrives?
Check package condition, enclosure, lead insulation, two-pin connector and label. Do not install a battery with impact, leakage, swelling or damaged wiring.
What information should appear in the maintenance record?
Record model, serial or lot details, receipt and installation dates, controller identity, measured condition and the next planned inspection or replacement date.
Practical support for automation-parts sourcing
PLCEXPORT supports maintenance, engineering and procurement teams with model verification, responsive quotations and coordinated international supply.
Recommended models
Published PLCEXPORT product links have been refreshed and regrouped for this IC693ACC302 page.
Allen-Bradley
| 1756-OF4 | 2711P-RDT10C | 1756-L62/B | 1769-ECR |
| 1771-OMD | 1762-IQ16 | 1734-EP24DC | 1769-CRL1 |
| 1747-M13 | 1747-L543 | 1747-L551 | 1769-IQ16 |
| 1794-IA8 | 1747-M12 | 1746-OW16 | 1746-IM16 |
| 1747-SN | 1746-A7 | 1756-M16SE | 1756-IV32 |
GE
Others - other recommended brands
|
Bachmann MX213
|
Keba C5-IPC
|
Advantech APAX-5580
|
Lütze 716425
|
|
Elmo G-MAS
|
Festo CPX-E-CEC
|
Gefran GFX4-IR
|
Jetter JC-440
|
|
Kontron KBox-A-150
|
Lenze c550
|
Nidec C200-064
|
PMA KS98-2
|
|
Sorel XHCC
|
Toshiba V200-16MR
|
Teco SG2-20VR
|
Wieland samosPRO
|
|
Zander TALOS-TB
|
Crouzet em4-remote
|
Hitachi EH-150
|
Unitronics USC-B10-T24
|
Confirm the exact IC693ACC302 before ordering
Share the full nameplate, installed configuration, clear connector or terminal photos, quantity and destination. Myrtle will review model identity and compatibility points before quotation.
The complete IC693ACC302 identity is checked rather than the base number alone.
Controller, carrier, rack, wiring or project details are compared before replacement.
Current product, label and connector photos reduce mismatch risk.
Quantity, destination, protective packing and shipment requirements are confirmed.
Hot Tags: ge ic693acc302 auxiliary battery module, China ge ic693acc302 auxiliary battery module manufacturers, suppliers, GE Fanuc IC695CPE302, GE IC695CEP001, IC695CEP001, IC695CEP001 CEP Carrier Module, IC695CPE302, IC695CPE302 CPU module