GE IC695PBS301-AA PACSystems RX3i PROFIBUS Slave Module

GE IC695PBS301-AA PACSystems RX3i PROFIBUS Slave Module

GE · PACSYSTEMS RX3I

GE IC695PBS301-AA PACSystems RX3i PROFIBUS Slave Module

PACSystems RX3i PROFIBUS DP slave module that automatically exchanges cyclic data with a PROFIBUS master; install it in a Universal Backplane and verify the complete -AA identification.

New & originalOne-year warranty3–5 daysCondition: In stock
Send Inquiry
Description
GE · PACSYSTEMS RX3I

GE IC695PBS301-AA PACSystems RX3i PROFIBUS Slave Module

PACSystems RX3i PROFIBUS DP slave module that automatically exchanges cyclic data with a PROFIBUS master; use a Universal Backplane and verify the complete -AA identification.
New & original
One-year warranty
3–5 days
Condition: In stock
Request a quote
Product overview

Description and purpose

The IC695PBS301-AA is a PACSystems RX3i PROFIBUS DP slave module. In normal operation it responds to requests from the PROFIBUS master and automatically exchanges the cyclic input and output data configured in the controller project; it does not control the bus as a master.

Install the module only in an IC695CHS012 or IC695CHS016 RX3i Universal Backplane. GE documentation requires an RX3i CPU with firmware 3.0 or later and Machine Edition Logic Developer PLC 5.0 SP3 or later for configuration.

Purchase verification

Confirm the complete -AA nameplate, Universal Backplane model, CPU firmware, station address, configured input/output areas, PROFIBUS master project, connector and termination before ordering.

Verified configuration

Technical specifications

Configuration data summarized from PACSystems RX3i PROFIBUS Modules User's Manual GFK-2301D and product information GFK-2375C. Match the full IC695PBS301-AA identity and the installed project before replacement.

Model
IC695PBS301-AA
Manufacturer
GE
Product family
PACSystems RX3i
Product type
PROFIBUS DP slave module
Backplane requirement
IC695CHS012 or IC695CHS016 Universal Backplane
Backplane current
440 mA at 3.3 V DC, typical
PROFIBUS connector
9-pin D-sub
Station address
1–125; default 1; each station must be unique
Data rate
Auto-detected, 9.6 kbit/s to 12 Mbit/s
Cyclic I/O capacity
Up to 244 bytes input and 244 bytes output
DP-V1 services
Read, Write and Alarm messages
Status data
Two-word Slave Status area
Indicators
PROFIBUS OK, Network and MOD STATUS LEDs
Minimum CPU level
RX3i CPU firmware 3.0 or later
Configuration software
Machine Edition Logic Developer PLC 5.0 SP3 or later
Revision identification
Verify the complete IC695PBS301-AA nameplate
Talk to Myrtle

Compatibility and quotation support

CONFIGURATION SUPPORT

Need a precise compatibility check?

Send Sales Manager Myrtle the complete IC695PBS301-AA nameplate, installed hardware details, required quantity and destination. We will review the stated configuration before quotation.

Sales Manager · Myrtle
Compatibility review
Use cases

Applications

PROFIBUS master integration

Adds an RX3i controller as a configured DP slave beneath an existing PROFIBUS master.

Cyclic process data

Transfers the input and output byte areas defined in the RX3i and master projects.

DP-V1 access

Supports configured acyclic Read, Write and Alarm services alongside cyclic exchange.

Installed-system replacement

Restores a documented slave station after address, data map and termination checks.

Supply terms

Ordering information

Payment · T/T
Port · Xiamen
Lead time · 3–5 days
Condition · In stock
Buyer questions

FAQ about IC695PBS301-AA

Can IC695PBS301-AA replace an IC695PBS301-BA without changing the PROFIBUS application?

GE product information describes the -BA release as a label-only change with no change to function, performance or compatibility. Even so, compare the full nameplate, the approved hardware catalog and the saved controller/master projects before fitting a replacement.

Which rack and controller versions must I check before ordering IC695PBS301-AA?

Confirm an IC695CHS012 or IC695CHS016 Universal Backplane, an RX3i CPU with firmware 3.0 or later, and Machine Edition Logic Developer PLC 5.0 SP3 or later. The module is not specified for an RX3i expansion or remote backplane.

Do I need to set the PROFIBUS baud rate manually on IC695PBS301-AA?

No. The module automatically detects the network rate from 9.6 kbit/s through 12 Mbit/s. You still need a unique station address from 1 to 125, matching master configuration, correct cable polarity and termination.

Why is IC695PBS301-AA powered but not exchanging data with the master?

Read the two-word Slave Status area and check whether the module is waiting for parameters, waiting for configuration, in normal data exchange or reporting an error. Then verify the master is in RUN, the station address is unique, the configured byte counts match and the cable and terminations are intact.

How much process data can IC695PBS301-AA exchange, and can DP-V1 reduce the available cyclic data?

The module supports up to 244 bytes of cyclic input data and 244 bytes of cyclic output data. DP-V1 Read, Write and Alarm buffers use module capacity, so confirm the actual cyclic and acyclic allocation in the project rather than assuming the maximum is always available.

What information should I provide to confirm IC695PBS301-AA stock and compatibility?

Send the complete -AA nameplate, Universal Backplane model, RX3i CPU and firmware, Machine Edition version, station address, configured input/output areas and lengths, master/GSD configuration, LED or Slave Status information, connector and termination photos, quantity and destination.

Global automation supply

About PLCEXPORT

PLCEXPORT supports maintenance, engineering and procurement teams sourcing industrial automation components. Each request is reviewed against the supplied nameplate, system context and destination.

Technical discussion
Technical discussionOur team checks system, suffix and interface details before quotation.
PLCEXPORT team
PLCEXPORT teamSales and technical colleagues coordinate model checks and order follow-up.
Packing inspection
Packing inspectionVisible labels, connectors and package condition are reviewed during preparation.
China operations
China operationsClear communication supports urgent and difficult-to-source automation requirements.
Brand references

Recommended models

BENTLY NEVADA

GE

Others - other recommended brands

Phoenix Contact AXC F 2152
Bosch Rexroth XM21
Wago PFC200
Bachmann MX213
Keba C5-IPC
Aaeon BOXER-6641
Advantech APAX-5580
Lütze 716425
Elmo G-MAS
Festo CPX-E-CEC
Gefran GFX4-IR
Jetter JC-440
Kontron KBox-A-150
Lenze c550
Nidec C200-064
PMA KS98-2
Sorel XHCC
Toshiba V200-16MR
Teco SG2-20VR
Wieland samosPRO
Zander TALOS-TB
Crouzet em4-remote
Hitachi EH-150
Idec FT1A-H40RSA
Sales support

Fast response from PLCEXPORT

CONFIGURATION SUPPORT

Need a precise compatibility check?

Send Sales Manager Myrtle the complete IC695PBS301-AA nameplate, installed hardware details, required quantity and destination. We will review the stated configuration before quotation.

Sales Manager · Myrtle
Compatibility review

Hot Tags: ge ic695pbs301-aa pacsystems rx3i profibus slave module, China ge ic695pbs301-aa pacsystems rx3i profibus slave module manufacturers, suppliers, GE Fanuc IC695CEP001, GE IC695CEP001, ge pac systems rx3i, IC695CEP001, IC695CEP001 CEP Carrier Module, IC695CPE302 CPU module

Send Inquiry