Allen-Bradley 1756-ENBT ControlLogix EtherNet/IP Communication Module

Allen-Bradley 1756-ENBT ControlLogix EtherNet/IP Communication Module

ALLEN-BRADLEY · CONTROLLOGIX ETHERNET/IP
1756-ENBT EtherNet/IP Communication Module

Chassis-mounted ControlLogix communication module with one 10/100 Mbps copper RJ45 port, supporting up to 64 TCP and 128 CIP connections.

New & original
One-year warranty
3–5 days
Condition: In stock
Send Inquiry
Description

 

ALLEN-BRADLEY CONTROLLOGIX ETHERNET/IP

Allen-Bradley 1756-ENBT EtherNet/IP Communication Module

A single-port ControlLogix network interface for controller messaging, distributed I/O communication and data exchange over EtherNet/IP.

New & original
One-year warranty
3–5 days
Condition: In stock
Request a quote

Description and purpose

The 1756-ENBT connects a ControlLogix chassis to an EtherNet/IP network through one copper RJ45 interface. It provides a path for controller-to-device messages, produced and consumed data, distributed I/O traffic and routing to nodes on other supported networks. Rockwell Automation lists 10/100 Mbps operation, 64 TCP connections and 128 CIP connections. The module is discontinued, so series, firmware and migration requirements should be checked before replacement.

Technical specifications

Values summarized from Rockwell Automation product data and publication 1756-TD003.

Model
1756-ENBT
Manufacturer
Allen-Bradley / Rockwell Automation
Country of origin
United States
Product family
ControlLogix
Product type
EtherNet/IP communication module
Module location
Any ControlLogix chassis slot
Ethernet interface
1 copper RJ45 port · Category 5
Communication rate
10/100 Mbps
Maximum TCP connections
64
Maximum CIP connections
128
Current draw
700 mA at 5.1 V DC · 3 mA at 24 V DC
Power dissipation
3.7 W
Isolation voltage
30 V continuous, network-to-backplane
Ethernet cable
IEEE 802.3 compliant twisted pair
Operating temperature
0–60 °C
Storage temperature
−40–85 °C
Relative humidity
5–95%, noncondensing
Enclosure
Open-style
Lifecycle
Discontinued since December 31, 2021
Functional replacement
1756-EN2T; engineering review required
CONTROLLOGIX COMPATIBILITY SUPPORT

Replacing a discontinued EtherNet/IP module?

Send Myrtle the complete 1756-ENBT nameplate, series, firmware revision, chassis or controller information and required quantity. We will review the identification details before quotation and flag points that may affect a 1756-EN2T migration.

Application scenarios

Distributed I/O communication

Connect a ControlLogix controller to EtherNet/IP I/O adapters and field devices within the module connection limits.

Controller data exchange

Carry produced and consumed tags between compatible Logix5000 controllers.

Explicit messaging

Provide a network path for controller messages and communication with other EtherNet/IP devices.

Legacy network maintenance

Maintain installed ControlLogix systems that still depend on the Series A 1756-ENBT architecture.

Ordering information

Payment
T/T
Port
Xiamen
Lead time
3–5 days
Condition
In stock

Product image and buyer checklist

1756-ENBT
1756-ENBT

What buyers should verify for 1756-ENBT

Before ordering a discontinued 1756-ENBT, confirm the exact module identity and how it is used in the existing ControlLogix project. These checks reduce firmware, capacity and migration surprises during replacement.

Catalog and revision
Match the complete 1756-ENBT catalog number, Series A marking and installed firmware. Ask for clear front-panel and side-nameplate photos.
Network fit
Confirm the copper RJ45 EtherNet/IP connection, 10/100 Mbps network design and the project connection load before fitting the module.
Replacement planning
Rockwell Automation identifies 1756-EN2T as a functional replacement; controller revision, chassis, network settings and project changes still require engineering review.
Quote information
Provide firmware revision, controller and chassis details, required quantity, destination and whether the request is for replacement stock or migration.
Buyer tip: A similar front appearance does not confirm firmware or project compatibility.

What buyers should verify

1. Full identification: catalog number, series and firmware revision.
2. Network capacity: TCP, CIP and I/O connection requirements.
3. Port configuration: speed, duplex and switch auto-negotiation settings.
4. Migration plan: firmware, AOP and project changes for 1756-EN2T.
BUYER QUESTIONS

FAQ about Allen-Bradley 1756-ENBT

Is Allen-Bradley 1756-ENBT suitable for my existing ControlLogix chassis?

The module is chassis-mounted and Rockwell Automation specifies installation in any ControlLogix chassis slot. Before replacement, confirm the complete catalog number, Series A hardware, firmware revision, available slot and controller project configuration.

Will Allen-Bradley 1756-ENBT support the number of devices and messages on my network?

Rockwell lists a maximum of 64 TCP connections and 128 CIP connections. Count I/O, produced/consumed tags, messaging and other explicit or implicit connections before deciding that the module has enough capacity.

Can Allen-Bradley 1756-ENBT be replaced directly by 1756-EN2T?

Rockwell identifies 1756-EN2T as the functional replacement, but a drop-in exchange should not be assumed. Verify firmware, Add-On Profile, IP settings, connection capacity, project revision and network behavior before migration.

Why can Allen-Bradley 1756-ENBT communication become slow after connecting it to a managed switch?

A speed or duplex mismatch can sharply reduce network performance. Check whether the module and switch port are both set for auto-negotiation or use matching manual 10/100 Mbps and half/full-duplex settings for the installed firmware revision.

What does the discontinued status of Allen-Bradley 1756-ENBT mean for maintenance planning?

Rockwell discontinued the model on December 31, 2021. Buyers should confirm the required series and firmware, keep a tested spare strategy, and evaluate 1756-EN2T migration separately rather than waiting for an emergency failure.

What information should I send when requesting an Allen-Bradley 1756-ENBT quotation?

Provide clear front and side nameplate photos, full catalog number, series, firmware revision, required quantity, current controller or chassis details and delivery destination. This helps avoid a visually similar but incompatible communication module.

PLCEXPORT support for ControlLogix communication projects

PLCEXPORT helps maintenance teams compare legacy ControlLogix communication hardware, confirm nameplate details and coordinate international supply.

Our team, workplace and order preparation

 
China sales and support team

Myrtle and the sales team coordinate model identification, quotation details and international order communication.

 
Technical discussion

Series, firmware, chassis and network details are reviewed before a supply option is proposed.

 
Warehouse verification

Visible labels, series information and package condition are checked during order preparation.

 
PLCEXPORT China

We support project and maintenance buyers sourcing current and legacy automation components.

Recommended Models

Published product references are grouped by brand; each card shows the model only.

ABB - published product references

SIEMENS - published product references

Other Brands

IDEC FT1A-H40RSA
Koyo DL06
Murrelektronik Cube67
Pilz PNOZmulti 2
Unitronics USC-B10-T24
Horner HE-XE105
Fatek FBs-20MC
ICP DAS I-8431W
Autonics ARIO-C-MR
Delta DVP28SV
Wago PFC200
Bachmann MX213
Keba C5-IPC
Aaeon BOXER-6641
Jetter JC-440
Kontron KBox-A-150
PMA KS98-2
Crouzet em4-remote

↑ BACK UP TO THE TOP

Hot Tags: 1756-ENBT, 1756-ENBT EtherNet/IP, Allen-Bradley 1756-ENBT, ControlLogix Ethernet module, 1756-ENBT manual, 1756-ENBT datasheet

EmailWhatsApp

Hot Tags: allen-bradley 1756-enbt controllogix ethernet/ip communication module, China allen-bradley 1756-enbt controllogix ethernet/ip communication module manufacturers, suppliers, 1746 OA16 pdf, 1746-OA16, 1771 P5 manual, allen bradley, Allen Bradley 1746 OA16, Allen Bradley 1746 OA16 Output Module PLC Module

Send Inquiry