Products Description of MVI56E-MNETXT
The MVI56E Modbus TCP/IP Client/Server Enhanced Communication Module allows Rockwell Automation ControlLogix processors to interface easily with Modicon Programmable Automation Controllers (PACs) and a wide variety of Modbus TCP/IP-compatible instruments and devices. MVI56E enhancements include local and remote configuration and diagnostics through the module's Ethernet port, CIPconnect technology for bridging through Rockwell Automation ControlNet and EtherNet/IP networks, and an on-board web
server for access to module documentation and sample program files.
The MVI56E-MNET and MVI56E-MNETXT are functionally the same. The MVI56E-MNET is designed for standard process applications. The MVI56E-MNETXT is designed for the Logix-XT control platform, allowing it to operate in extreme environments, at higher operating temperatures, and has a conformal coating to protect it from harsh or caustic conditions.

Hardware Specifications of MVI56E-MNETXT
| Specification | Description |
|---|---|
| Backplane Current Load | 800 mA @ 5 VDC3 mA @ 24 VDC |
| Operating Temperature | 0°C to 60°C (32°F to 140°F) - MVI56E-MNET-25°C to 70°C (-13°F to 158°F) - MVI56E-MNETXT |
| Storage Temperature | -40°C to 85°C (-40°F to 185°F) |
| Shock | 30 g operational50 g non-operational |
| Vibration | 5 g from 10 Hz to 150 Hz |
| Relative Humidity | 5% to 95% RH, non-condensing |
| LED Indicators | Battery Status (ERR)Application Status (APP)Module Status (OK) |
| 4-Character Scrolling Alphanumeric LED Display | Displays module information, firmware version, IP address, application port settings, port status, and error information |
| Debug / Configuration / Application Ethernet Port (E1) | 10/100 Base-T Ethernet, RJ45 connector (CAT5)Link and Activity LEDsAuto-crossover cable detection |
| Shipped with Unit | 5-foot Ethernet straight-through cable |
| Part Number | TCP-P-C |
Features and Benefits
| Feature | Description | Benefits / Notes |
|---|---|---|
| Backward Compatibility | Upgrade earlier MVI56-MNET modules without changing existing ladder logic programs or module configurations | Enhanced features and flexibility without incurring expensive reprogramming costs |
| For Extreme Environments (MV156E-MNETXT Only) | Conforms to EN60079-0 and EN60079-15 standards for use in caustic and extreme temperature environments | Operates from -25°C to 70°C (-13°F to 158°F); conformal coating protects against corrosive elements |
| RSLogix 5000 Integrated | Module communication is integrated within RSLogix 5000 using a sample Add-On Instruction (AOI) or sample ladder logic file | Simplifies configuration and reduces engineering time |
| Graphical User Interface Software | ProSoft Configuration Builder (PCB) provides online or offline configuration and diagnostics via a high-speed Ethernet port | CIPconnect-enabled, allowing remote configuration and diagnostic access across bridged EtherNet/IP and ControlNet networks using Rockwell Automation 1756-ENxT and 1756-CNB modules |
| Web-Enabled Ethernet Port with Discovery Service | Embedded web server provides local access to documentation, module status, and firmware update utilities | ProSoft Discovery Service locates MVI56E modules on the network and assigns a temporary IP address for easy setup |
Contact US
Our address
32D floor, Guomao Building, No.388, Hubin South Road, Siming District, Xiamen
Phone Number/Whatsapp/Wechat
+86 18030132586
cn@mooreplc.com

Frequently Asked Questions
What is your return policy?
+
-
1) Defective Items: Report any defects within 3 days of delivery.
2) Return Condition: Items must be returned unused and in original packaging for refund/replacement.
3) Quality Issues: If an item has a manufacturing defect, you may return it within 7 days for a full refund or replacement.
How do you ensure product MVI56E-MNETXT quality?
+
-
Prosoft MVI56E-MNETXT Modbus Communication Module undergoes strict quality inspection before shipment. In rare cases where issues arise, we will notify you promptly.
What is the primary purpose of the MVI56E-MNETXT module?
+
-
The MVI56E-MNETXT serves as a network interface for Modbus TCP/IP communication, allowing ControlLogix PLCs to exchange data with Modbus servers and clients across Ethernet networks.
Where is the MVI56E-MNETXT typically installed?
+
-
The module is installed directly in a ControlLogix chassis, occupying a standard slot and integrating seamlessly with the backplane and Ethernet infrastructure.
Are software or program changes required when replacing the module?
+
-
In most cases, no changes to existing PLC logic or configuration are necessary, provided the replacement module uses the same setup and network parameters.
Recommendations
| 51109693-100B | 1398-DDM-005 | NBIO-21CU | PM154 3BSE003645R1 |
| 51195153-001 | 2711P-T7C21D8S | MIVII1000E00HI00 | PM153 3BSE003644R1 |
| 51195153-005 | IOP303 | 1440-VST02-01RA | IS200WETBH1BAA |
| 51195153-902 | IOP335 | 6ES7135-0HF01-0XB0 | 2711-B6C8L1 |
| 51195199-010 | IC697VAL314 | XAGO12H | PR6423/002-030 |
| 51196041-100 | 1336S-EN4 42336-221-51 | DSQC627 3HAC020466-001 | 1785-L40L |
| 51196694-928 | AAB841 | 51403519-160 K4LCN-16 | IS200WETBH1ABA |
| 07MK92 GJR5253300R3161 | 6ES7952-1AS00-0AA0 | TM0180-A07-B00-C05-D10 | YHC4150X-01?YHC4150X |
| 1336F-MCB-SP2L 164989 | IS210AEBIH1B IS210AEBIH1BED | TM0182-A50-B00-C00 | KJ3221X1-BA1 12P2531X102 |
| TB820V2 3BSE013208R1 | LINK-H | NMTU-21C 3BSE017429R1 | 330190-080-01-00 |
| TU811V1 3BSE013231R1 | AI845-EA 3BSE023675R2 | 2711C-K3M | DYSF118B 61430001-XG |
| PM573-ETH 1SAP130300R0271 | 51305430-100 | MVI69E-MBTCP | DYTP600A 6143001-ZY |
| TU515 1SAP212200R0001 | DS3820PS7A1B1C | 1326AB-B720E-S2L | DTCA717A 61430001-WH |
Hot Tags: prosoft mvi56e-mnetxt network interface module, China prosoft mvi56e-mnetxt network interface module manufacturers, suppliers, ProSoft MVI56 MCM, MVI56E MCM pdf, MVI69-MCM, prosoft module, MVI56E-MCM, MVI69 MCM manual