Prosoft MVI69-MNETC Modbus Communication Module

Prosoft MVI69-MNETC Modbus Communication Module

Dimensions: 3.9x8.6x13 cm
Weight: 0.2 kg
Contact Sales Felicia for quotation and more info:
Mobile: +86 18030132586
Email: cn@mooreplc.com
Whatsapp(Wechat): +86 18030132586
Send Inquiry
Description

Products Description of MVI69-MNETC

 


   The MVI69-MNETC Modbus TCP/IP Client Communication Module allows Rockwell Automation CompactLogix / MicroLogix processors to interface easily with Modbus TCP/IP server devices. Compatible devices include Modicon PACs, as well as a wide variety of instruments and devices. The module acts as an input/output module between the Modbus network and the Rockwell Automation backplane. The data transfer from the processor is asynchronous from the actions on the Modbus Client-controlled network. A 5000-word register space in the module exchanges data between the processor and the Modbus network.

 

Hardware Specifications of MVI69-MNETC

 

 

Item Specification
Dimensions Standard 1769 single-slot module
Current Load 800 mA max @ 5 VDC
Power-Supply Distance Rating 2 (L43 & L45 installations on first 2 slots of 1769 bus)
Operating Temperature 0 to 60 °C (32 to 140 °F)
Storage Temperature –40 to 85 °C (–40 to 185 °F)
Relative Humidity 5%–95% RH, non-condensing
Indicators Power & Module Status, Application Status, CFG Port Activity, Ethernet Port Activity, Error Status
Interface RJ45 (DB-9M with supplied cable), RS-232 only, no hardware handshaking
Electrical 10/100 Base-T, 1500 Vrms isolation @ 50–60 Hz for 60 s per IEC 60950:1991 §5.3.2
Broadcast-Storm Resiliency ≤ 5000 ARP frames/s for ≤ 5 min
Cables RJ45-to-DB-9M cables for each port; 6-ft RS-232 configuration cable

 

Installing the Module in the Rack

 

 

   It describes how to install the module into a CompactLogix or MicroLogix rack.
   Before you attempt to install the module, make sure that the bus lever of the adjacent module is in the unlocked (fully right) position.
Warning: This module is not hot-swappable! Always remove power from the rack before inserting or removing this module, or damage may result to the module, the processor, or other connected devices.
1. Align the module using the upper and lower tongue-and-groove slots with the adjacent module and slide forward in the direction of the arrow.

product-648-346
2. Move the module back along the tongue-and-groove slots until the bus connectors on the MVI69 module and the adjacent module line up with each other.
3. Push the module's bus lever back slightly to clear the positioning tab and move it firmly to the left until it clicks. Ensure that it is locked firmly in place.
4. Close all DIN-rail latches.
5. Press the DIN-rail mounting area of the controller against the DIN-rail. The latches will momentarily open and lock into place.

 

Contact US

 

 

How To Cooperate With Us?

Our address

32D floor, Guomao Building, No.388, Hubin South Road, Siming District, Xiamen

Phone Number/Whatsapp/Wechat

+86 18030132586

E-mail

cn@mooreplc.com

product-800-520
 

 

Frequently Asked Questions
 
 

What is your return policy?

+

-

1) Defective Items: Report any defects within 3 days of delivery.

2) Return Condition: Items must be returned unused and in original packaging for refund/replacement.

3) Quality Issues: If an item has a manufacturing defect, you may return it within 7 days for a full refund or replacement.

How do you ensure product MVI69-MNETC quality?

+

-

Prosoft MVI69-MNETC Modbus Communication Module undergoes strict quality inspection before shipment. In rare cases where issues arise, we will notify you promptly.

What is the main function of the MVI69-MNETC module?

+

-

MVI69-MNETC Modbus Communication Module acts as a bridge between Modbus TCP/IP devices and ControlLogix controllers, enabling reliable data transfer and command execution across industrial networks.

How is the module configured?

+

-

Configuration is performed via the serial debug/config port or Ethernet-based configuration tools. The module allows backup, restore, and replication of settings across multiple modules.

Is it compatible with legacy and modern systems?

+

-

Yes. The MVI69-MNETC supports older Modbus TCP/IP devices and modern ControlLogix controllers, providing a flexible solution for network integration and gradual system upgrades.

 

Recommendations

 

 

S9345FA MFDT-01 SAI143-H03 S2 ICRXIBN7M000A-BA
SNT401-53 S1 SREA-01 SAI143-S33/PRP S2 1SAP120600R0001 PM554-TP
SNT401-53 S1 FEN-01 68679273 SAI533-H03 S1 1SAP120800R0001 PM554-RP-AC
E1697.32 FEN-31 68978840 SAI533-H33 S1 1SAP120900R0071 PM564-TP-ETH
211QS10538C FEN-01 68679273 SAI533-H63 S1 1SAP121000R0001 PM564-RP
211QS10540C IS200TBAIH1CCC SCP451-11 S1 1SAP121200R0071 PM556-TP-ETH
211QS10533C IS200TRPGH1BCC SCP461-11 S1 1SAP140500R0271 PM585-ETH
211QS10598C IS200TRTDH1CCC SCP461-E1 S2 1SAP250000R0001 AX522
APROTB 223544 IS200TREGH1BDB SDV144-S13 S1 1SAP530200R0001 CP630-WEB H1
IS200VSVOH1BED IS200TTURH1BCC SDV144-S13 S4 1SAP535100R0001 CP635
CM3201 S2 IS200TTURH1BCC IC695CPE400-AAAA 1SAP540710R0001 CP6407
IS420CCGAH2A TX560 3BSE005881R1 IC695CPE400-ABAB 3BHB003688R0101 KUC711 AE101
4303-MNET-MBP 3BHE044249R4002 GDC806 C4002 IC695CPL410-AAAA 3BHB007030R0103 UFC760 BE103
1797-IE8H BINT-12C 3AUA0000077967 IC695CPL410-AAAC 3BHB022793R0001 ASE2 UDC920 AE01

 

Hot Tags: prosoft mvi69-mnetc modbus communication module, China prosoft mvi69-mnetc modbus communication module manufacturers, suppliers, ProSoft MVI56 MCM, MVI56E MCM pdf, MVI69-MCM, prosoft module, MVI56E-MCM, MVI69 MCM manual

Send Inquiry