Product Summary
The MVI56-MCM is a Modbus communication module developed for ControlLogix systems. It enables direct serial Modbus RTU and Modbus ASCII communication without requiring an external gateway. The module fits into any ControlLogix chassis slot and is often used to link PLC systems with drives, analyzers, meters, or legacy controllers that rely on Modbus serial protocols.
Technical Data
|
Protocol |
Modbus RTU / Modbus ASCII |
|
Ports |
2 × RS‑232/RS‑485 serial interfaces |
|
Chassis |
Standard ControlLogix slot |
|
Typical Data Capacity |
Up to thousands of registers per direction |
|
Baud Rate |
300 to 115.2 kbps |
|
Operating Conditions |
0°C – 60°C |
|
Tools |
ProSoft Configuration Builder, Studio 5000 integration files |
|
Power Consumption |
Uses ControlLogix chassis power |
Functional Characteristics
• Supports Modbus Master and Slave modes
• Two independent serial channels
• Configurable communication parameters for each port
• Data exchange handled through ControlLogix tags
• Diagnostic monitoring for connection status and communication loading
• Designed for continuous, high-volume serial data transfer
Application Scenarios
• Connecting Modbus-based field instruments to ControlLogix
• Migrating older Modbus equipment into new automation platforms
• Industrial plants where Modbus remains the standard field protocol
• Energy, manufacturing, utilities, and processing environments
Installation Notes
• The module operates as part of the ControlLogix backplane, no external power required
• Proper RS-485 grounding and termination improve signal reliability
• Port configurations must match the connected Modbus devices
• Clear separation of Master and Slave roles avoids communication conflicts
About PLC Export
PLC EXPORT supplies industrial automation components, including PLC modules, communication interfaces, and control parts. We support customers in energy, petrochemical, manufacturing, and automation projects. Our strengths include reliable sourcing, quick delivery, and guidance on module compatibility. We focus on providing stable, practical solutions for engineering teams and maintenance departments.
MVI56-MCM – Product FAQ
Q1: Does the module allow both ports to run in different modes?
A: Yes. One port may run as Master while the other operates as Slave.
Q2: Can the module replace a standalone Modbus gateway?
A: In most cases, it can. The module handles Modbus communication directly within the chassis.
Q3: What is the maximum number of devices on an RS‑485 network?
A: Typically 32 devices per segment, depending on cable and termination.
Q4: Are configuration examples available?
A: Sample programs and logic routines are provided by ProSoft.
Contact Information
Email: sales3@mooreplc.com
WhatsApp / Phone: +8618020714662
Hot Tags: prosoft mvi56-mcm slave communication module, China prosoft mvi56-mcm slave communication module manufacturers, suppliers, ProSoft MVI56 MCM, MVI56E MCM pdf, MVI69-MCM, prosoft module, MVI56E-MCM, MVI69 MCM manual