Overview
The MVI69-MCM is a Modbus communication module designed for Rockwell CompactLogix and MicroLogix™ 1400/1500 platforms. It provides a practical way to integrate Modbus serial devices into Logix-based control systems without adding external gateways or rewriting automation programs. This module is commonly used in applications where equipment from different vendors must exchange data reliably through Modbus RTU or Modbus ASCII protocols.
Technical Specifications
|
Module Type |
1769 Compact I/O communication module |
|
Protocol |
Modbus RTU / ASCII |
|
Serial Ports |
2 × RS-232/RS-485 |
|
Power Consumption |
800 mA @ 5 VDC |
|
Speed |
300 to 115.2 kbps |
|
Data Handling |
4,000 integers in/out |
|
Operating Temp |
0°C to 60°C |
|
Tools |
ProSoft Configuration Builder, Studio 5000 AOP |
Core Capabilities
1. Modbus Master / Slave Support
- Handles both Master and Slave roles
- Suitable for point-to-point or multi-drop serial networks
2. Logix Integration
- Add-on Profile (AOP) for easy configuration in Studio 5000
- Data exchange via user-defined tags
- Diagnostic tags for real-time monitoring
3. Performance Features
- Supports up to 4,000 registers in each direction
- Efficient buffer handling
- Isolated ports for noise immunity
Typical Applications
Integration of drives, meters, analyzers, Modbus sensors
Retrofitting legacy Modbus equipment
SCADA field communication
Cross-vendor automation networking
Installation
- Occupies one 1769 rack slot; verify rack power budget
- Follow proper grounding for stable serial communication
- Ensure RS-485 termination and biasing are correct
About PLC Export
PLC EXPORT supplies industrial automation spare parts, communication modules, and control components. We support clients in power, manufacturing, oil & gas, and process industries. Our services include sourcing discontinued modules, fast delivery, and technical guidance. Reliability and consistent support are our priorities.
MVI69-MCM – Product-Specific FAQ
1. Can it run as both Master and Slave?
Yes. Each port can be configured independently.
2. Do I need an external gateway?
Usually not. The module provides direct Modbus communication.
3. How many devices can connect?
Typically up to 32 nodes per RS-485 segment.