Products Description of PLX31-EIP-PND
The EtherNet/IP to PROFINET I/O Device (slave) gateway offers bi-directional data transfers between EtherNet/IP controllers and a PROFINET I/O controller. The EtherNet/IP Driver supports I/O connections for guaranteed data delivery or Message instructions to send data to/from the PACs. The gateway supports 1440 bytes of input data and 1440 bytes of output data for larger applications.
In addition, the gateway's multiple I/O connections allow you to set different RPIs for control data and module diagnostics, enabling you to optimize your Ethernet bandwidth.

Hardware Specifications of PLX31-EIP-PND
| Specification | Description |
|---|---|
| Number of Class 3 Server Connections | 5 |
| Supported PLC Types | PLC-2, PLC-5, SLC, ControlLogix (CLX), CompactLogix (CMPLX), MicroLogix |
| Supported Message Types | PCCC, CIP |
| Number of Class 3 Client Connections | Connected: 2Unconnected: 1 |
| Number of Class 1 I/O Connections | 8 |
| Maximum I/O Connection Size (Input / Output) | 496 bytes / 496 bytes |
| Minimum RPI (Requested Packet Interval) | 10 ms per connection |
| Supported CIP Services | 0x4C – CIP Data Table Read0x4D – CIP Data Table WriteCIP Generic Services |
| Command List Capacity | Up to 100 commands per client, configurable by command type, IP address, register addressing, and word/bit count |
| Supported Command Sets | PLC-2 / PLC-3 / PLC-5 Basic Command SetPLC-5 Binary Command SetPLC-5 ASCII Command SetSLC-500 Command Set |
Features and Benefits
1. Embedded EDS Add-On Profile allows for simplified integration and reduced configuration time for Rockwell Automation PACs.
2. No ladder programming is required when using I/O connections.
3. Multiple I/O connections allow you to set different RPIs for status and control data, enabling Ethernet bandwidth optimization.
4. Communication via an I/O connection provides guaranteed data delivery and enables a PAC to monitor for communication faults.
5. SD card slot (SD card optional) is used for storing configuration files in the event of a disaster.
6. ProSoft Discovery Service allows your PC to find the gateway and edit its default IP address without being on the same subnet.
7. Video setup tutorial provided at psft.com/Ap5
8. Secure module configuration via module switch (v1.04 and greater).
9. Up to 10,000 16-bit registers can be used to exchange large amounts of data.
Contact US
Our address
32D floor, Guomao Building, No.388, Hubin South Road, Siming District, Xiamen
Phone Number/Whatsapp/Wechat
+86 18030132586
cn@mooreplc.com

Frequently Asked Questions
What is your return policy?
+
-
1) Defective Items: Report any defects within 3 days of delivery.
2) Return Condition: Items must be returned unused and in original packaging for refund/replacement.
3) Quality Issues: If an item has a manufacturing defect, you may return it within 7 days for a full refund or replacement.
What role does the MVPLX31-EIP-PND play in an automation system?
+
-
The MVPLX31-EIP-PND functions as an industrial gateway that enables real-time data exchange between EtherNet/IP devices and PROFINET controllers, allowing two different Ethernet-based protocols to operate within the same system.
Where is the MVPLX31-EIP-PND typically mounted?
+
-
It is commonly installed on a DIN rail inside a control cabinet, positioned near network switches and controllers to simplify Ethernet wiring and maintenance access.
Does replacing the gateway require changes to PLC programs?
+
-
In most replacement scenarios, existing controller programs remain unchanged. As long as the new unit is configured with the same network parameters, no software redesign is required.
What issues may indicate a failing or unstable module
+
-
Typical symptoms include loss of PROFINET device visibility, EtherNet/IP connection drops, delayed I/O updates, or persistent fault indicators on the module LEDs.
Recommendations
| 1785-LT3 | EMDR-10 | FX61C BN624A551G51 | 1C31233G04 |
| 3500/32M | PM645C 3BSE010537R1 | 1C31110G03 | 1X00188H01 |
| 1771-CP1 | 9907-164 | 1C31142G01 | 1756-OA16 |
| 1771-NC6 | E42HLLB-LNK-NS-01 | PR9376/010-011 | F7105A |
| 1771-NC15 | DS3800HISA1A1A | 3A99266G01 | CI615 3BHT300024R1 |
| C1900/0263/0260A C1900/0263 | T921D-1008 T921D 1008 | A413135 AOU4 | IC693MDL231 |
| DSMB151 57360001-K | DS3800NSFE1E1B | A413311 | 1746SC-INI4VI |
| YXU149 YT296000-RX | YXT115B 4890024-NK | A413143 BIU84 | 1395-A65N-C1-PZ |
| C1900/0363 C1900/0363/0360A | K42HLHN-LNK-NS-01 | A413325 | ACX633 51196655-100 |
| DSMB114 57360001-MG | DS200SHVMG1AED | A413125 AIU8 | DSQC609 3HAC14178-1 |
| YXU144 YT296000-MC YXU 144 | 531X300CCHBDM3 | A413160 FIU1 | DSTK183 2639603-BX |
| DSBC111 57310256-K | 686B167U05 | A413511-02 | DSTK150 26390603-A |
| 086363-002 OSPS2 | DS200PCCAG10ACB | TM0182 TM0182-A50-B01-C00 | 1336F-BRF10-AA-EN |
| YXO126 4890024-UN YXO 126 | A413295 AIR8C | IC693PTM101 | ADM-1815BP |
| DSBC110 57310256-E | A413280 CPR1 | AX645 3BHB001914R1 3BHB001914R0001 | MICROBOX-6824A |
Hot Tags: prosoft plx31-eip-pnd ethernet/ip to profinet io device gateway module, China prosoft plx31-eip-pnd ethernet/ip to profinet io device gateway module manufacturers, suppliers, ProSoft MVI56 MCM, MVI56E MCM pdf, MVI69-MCM, prosoft module, MVI56E-MCM, MVI69 MCM manual