Prosoft PLX51-DF1-ENI Routing Module

Prosoft PLX51-DF1-ENI Routing Module

Dimensions: 2.2x11.8x10 cm
Weight: 0.12 kg
Contact Sales Felicia for quotation and more info:
Mobile: +86 18030132586
Email: cn@mooreplc.com
Whatsapp(Wechat): +86 18030132586
Send Inquiry
Description

Products Description of PLX31-EIP-PND

 


  The PLX51-DF1-ENI is able to transfer data from a DF1 device to a maximum of eight Logix controllers. The module operates in one of four modes, simplifying the configuration for all applications.

Operating Mode Description
Message Initiator Bridge Redirects DF1 PCCC messages to a Logix remote controller using a preconfigured EtherNet/IP path. Logix PLC mapping may be required. This mode also supports remote programming with RSLogix 5 and RSLogix 500.
DF1 Slave Remote Device Converts DF1 PCCC messages into Logix controller tag read and write operations. No Logix PLC mapping configuration is required in this mode.
Scheduled Tag Transfer Exchanges data between a DF1 device and multiple Logix controller tags based on a predefined schedule. No configuration changes are required on the Logix controller or the DF1 device.
Unscheduled Logix Messaging Transfers data using messages initiated by Logix Message (MSG) instructions received by the gateway.

   Hereafter the PLX51-DF1-ENI will be referred to as the module.
   The module can operate in both a Logix "owned" and standalone mode. With a Logix connection, the input and output assemblies will provide additional diagnostics information which will be available in the Logix controller environment.
   The module uses isolated RS232 for DF1 communication providing better noise immunity. The RS232 port also uses a terminal block for convenient installation. The module can also be used in systems with redundant DF1 pathways.
   A built-in webserver provides detailed diagnostics of system configuration and operation, including the display of received DF1 communication packets, without the need for any additional software.

product-1105-452

 

Hardware Specifications of PLX31-EIP-PND

 

 

Item Specification
Enclosure Plastic
Enclosure Rating IP20, NEMA / UL Open Type
Dimensions (H × W × D) 101.0 × 22.5 × 120.0 mm
Power Requirements 10 – 28 VDC input (70 mA @ 24 VDC / 130 mA @ 10 VDC)
Power Consumption 1.7 W
Power Connector 3-way terminal block
Supported Conductors 24 – 18 AWG
Operating Temperature –20 °C to +70 °C
Earth Connection Yes, terminal-based grounding

 

Item Specification
Connector Type RJ45
Supported Cable CAT5 STP / UTP
Maximum ARP Sessions 20
Maximum TCP Sessions 20
Maximum CIP Sessions 10
Communication Speed 10 / 100 Mbps
Duplex Mode Full / Half / Auto-Negotiate
Auto-MDIX Supported

 

Features and Benefits

 

 

1. Intelligent routing to ControlLogix or CompactLogix from PLC-5, SLC, MicroLogix controllers SCADA, DCS gateways and more
2. Direct-to-tag technology simplifies data mapping, reducing configuration time
3. Secure module configuration via on module switch
4. Can be used in a redundant ControlLogix system
5. Built-in packet analyzer for DF1 networks to assist in trouble shooting serial network issues

 

Contact US

 

 

How To Cooperate With Us?

Our address

32D floor, Guomao Building, No.388, Hubin South Road, Siming District, Xiamen

Phone Number/Whatsapp/Wechat

+86 18030132586

E-mail

cn@mooreplc.com

product-800-520

 

Frequently Asked Questions
 
 

What is your return policy?

+

-

1) Defective Items: Report any defects within 3 days of delivery.

2) Return Condition: Items must be returned unused and in original packaging for refund/replacement.

3) Quality Issues: If an item has a manufacturing defect, you may return it within 7 days for a full refund or replacement.

What is the primary purpose of the PLX51-DF1-ENI module

+

-

The PLX51-DF1-ENI acts as a protocol gateway that connects DF1 serial devices with EtherNet/IP-based Logix controllers, enabling legacy Allen-Bradley equipment to communicate over modern Ethernet networks.

Where is the PLX51-DF1-ENI typically installed?

+

-

It is normally DIN-rail mounted inside a control cabinet, positioned between DF1 serial devices and the EtherNet/IP network for efficient wiring and simplified panel layout.

What are common symptoms of a failing PLX51-DF1-ENI

+

-

Common indicators include DF1 communication timeouts, failed PCCC messaging, loss of Ethernet connectivity, or abnormal LED status conditions on the gateway.

How is the PLX51-DF1-ENI configured?

+

-

Configuration is performed through the module's configuration interface using ProSoft tools. The gateway supports multiple operating modes, including DF1 slave, message initiator, and scheduled tag transfer.

 

Recommendations

 

 

1785-LT3 EMDR-10 FX61C BN624A551G51 1C31233G04
3500/32M PM645C 3BSE010537R1 1C31110G03 1X00188H01
1771-CP1 9907-164 1C31142G01 1756-OA16
1771-NC6 E42HLLB-LNK-NS-01 PR9376/010-011 F7105A
1771-NC15 DS3800HISA1A1A 3A99266G01 CI615 3BHT300024R1
C1900/0263/0260A C1900/0263 T921D-1008 T921D 1008 A413135 AOU4 IC693MDL231
DSMB151 57360001-K DS3800NSFE1E1B A413311 1746SC-INI4VI
YXU149 YT296000-RX YXT115B 4890024-NK A413143 BIU84 1395-A65N-C1-PZ
C1900/0363 C1900/0363/0360A K42HLHN-LNK-NS-01 A413325 ACX633 51196655-100
DSMB114 57360001-MG DS200SHVMG1AED A413125 AIU8 DSQC609 3HAC14178-1
YXU144 YT296000-MC YXU 144 531X300CCHBDM3 A413160 FIU1 DSTK183 2639603-BX
DSBC111 57310256-K 686B167U05 A413511-02 DSTK150 26390603-A
086363-002 OSPS2 DS200PCCAG10ACB TM0182 TM0182-A50-B01-C00 1336F-BRF10-AA-EN
YXO126 4890024-UN YXO 126 A413295 AIR8C IC693PTM101 ADM-1815BP
DSBC110 57310256-E A413280 CPR1 AX645 3BHB001914R1 3BHB001914R0001 MICROBOX-6824A

 

Hot Tags: prosoft plx51-df1-eni routing module, China prosoft plx51-df1-eni routing module manufacturers, suppliers, ProSoft MVI56 MCM, MVI56E MCM pdf, MVI69-MCM, prosoft module, MVI56E-MCM, MVI69 MCM manual

Send Inquiry