Prosoft PLX32-EIP-PND EtherNet/IP To PROFINET Gateway Module

Prosoft PLX32-EIP-PND EtherNet/IP To PROFINET Gateway Module

Dimensions: 10x9.5x7 cm
Weight: 0.2 kg
Contact Sales Felicia for quotation and more info:
Mobile: +86 18030132586
Email: cn@mooreplc.com
Whatsapp(Wechat): +86 18030132586
Send Inquiry
Description

Products Description of PLX32-EIP-PND

 

 

   The PLX32-EIP-PND is an industrial communication gateway engineered to bridge EtherNet/IP and PROFINET systems in automation environments where multi-protocol integration is required. It enables reliable, two-way data exchange between PROFINET controllers and EtherNet/IP-based devices without modifying existing control logic.

   Designed as a self-contained, DIN-rail mountable unit, the PLX32-EIP-PND features dual Ethernet interfaces, each operating on an independent network segment. This architecture improves network separation, enhances stability, and simplifies integration across different industrial Ethernet infrastructures.

   On the EtherNet/IP side, the PLX32-EIP-PND supports both implicit Class 1 I/O messaging and explicit Class 3 messaging, offering flexibility for real-time and non-real-time data handling. On the PROFINET side, the module functions as a PROFINET Class A device, ensuring compatibility with standard PROFINET controller implementations.

 

Hardware Specifications of PLX32-EIP-PND

 

 

Item Specification
Class 3 Server Connections 5
Supported PLC Types PLC-2, PLC-5, SLC-500, CompactLogix, ControlLogix, MicroLogix
Supported Message Types PCCC, CIP
Class 3 Client Connections Connected: 2 / Unconnected: 1
Class 1 I/O Connections 8
I/O Data Size (Input/Output) 496 bytes / 496 bytes
Minimum RPI 5 ms per connection
Supported Services 0x4C – CIP Data Table Read; 0x4D – CIP Data Table Write
Commands per Client Up to 100 (configurable type, IP address, register range, word/bit count)
Supported Command Sets PLC-2/3/5 Basic, PLC-5 Binary, PLC-5 ASCII, SLC-500
Device Class Class A
Cyclic Data Capacity 1,440 bytes Input / 1,440 bytes Output
Data Exchange Modes Cyclic Real-Time (RT) and Acyclic
Nominal Voltage / Range 24 VDC nominal (10–36 VDC)
Current Consumption 300 mA @ 24 VDC; maximum 610 mA @ 10 VDC
Operating Temperature –25 to +70 °C (–13 to +158 °F)
Storage Temperature –40 to +80 °C (–40 to +176 °F)
Relative Humidity 5% to 95% RH, non-condensing

 

Contact US

 

 

How To Cooperate With Us?

Our address

32D floor, Guomao Building, No.388, Hubin South Road, Siming District, Xiamen

Phone Number/Whatsapp/Wechat

+86 18030132586

E-mail

cn@mooreplc.com

product-800-520

Benefits and Features

 

 

1. ODVA Approved
2. PROFINET v2 certification with PROFINET Class A compliance
3. EtherNet/IP and PROFINET certifications ensure the device is compatible with their respective network
4. Field-tested with multiple PROFINET controllers from multiple vendors
5. Remotely view and diagnose EtherNet/IP and PROFINET networks
6. Embedded EDS AOP provided to allow for seamless integration to Studio 5000 and RSLogix 5000
7. Using EtherNet/IP I/O connections, no ladder programming is required
8. Multiple I/O connections to allow for increased throughput
9. Secure module configuration via module switch (v1.04 and greater)
10. Up to 10,000 16-bit registers can be used to exchange large amounts of data

 

Frequently Asked Questions
 
 

What is your return policy?

+

-

1) Defective Items: Report any defects within 3 days of delivery.

2) Return Condition: Items must be returned unused and in original packaging for refund/replacement.

3) Quality Issues: If an item has a manufacturing defect, you may return it within 7 days for a full refund or replacement.

How do you ensure product PLX32-EIP-PND quality?

+

-

Prosoft PLX32-EIP-PND undergoes strict quality inspection before shipment. In rare cases where issues arise, we will notify you promptly.

What is the primary role of the ProSoft PLX32-EIP-PND gateway?

+

-

The PLX32-EIP-PND is used to exchange data between EtherNet/IP devices and PROFINET controllers, allowing equipment on different industrial Ethernet networks to communicate without modifying existing control programs.

Does the gateway process data continuously during system operation?

+

-

Yes. Unlike startup-only components, the PLX32-EIP-PND operates continuously, managing cyclic and acyclic data transfers while the automation system is running.

Which industrial networks and controllers are supported by this module?

+

-

This gateway connects PROFINET controllers with EtherNet/IP-based PLCs and devices, making it suitable for mixed-protocol environments commonly found in modern industrial systems.

 

Recommendations

 

 

IS200PDIOH1A 51401594-200 133396-01 8440-2028
81001-451-62-R GU-D15 6DD1688-0AE0 BWU1488 NMFC03
PTQ-PDPMV1 XC5010C F7541 330180-X2-05
CC-PAON01 51410070-176 171CCS78000 810-099175-103 8163-4002
990-05-XX-01-00 MOD:165335-01 CMON4108 VME-LTNI-S4 B105-0102 8177-4002
IC755CSW07CDACA-CG 990-05-70-02-00 990-10-XX-01-05 AAT141-S03 S2
330103-00-13-10-02-00 990-05-70-02-05 ADV161-P50 S2 PR6423/10R-040
990-05-70-02-01 EC-BOM-G009HLA012 330910-14-19-10-02-00 PR6424/000-130 CON021
PR6424/011-010 CON021 80173-110-02 G651885C 990-05-XX-03-05 147202-01 SPW482-E3 S1
PR6426/010-040 CON021/916-160 BCU-22 3AUA0000110431 330910-014-19-10-02-00 1785-L60B/C
BCU-22 3AUA0000110431 BCU-22 3AUA0000110431 PR6423/002-130 CON021 EC-BOM-G009HLA005
BCU-22 3AUA0000110431 EX10*MPS31 EX10-MPS31 PR6423/003-110 CON021 IIMGC01 SX-9000/64-8/B2
EX10*MPS31 EX10-MPS31 KJ3222X1-BK1 12P4705X062 SE4003S2B1 BSFC-02C 3AXD50000011461 NEYRPIC SL1000 V3 669187C/0572

 

 

Hot Tags: prosoft plx32-eip-pnd ethernet/ip to profinet gateway module, China prosoft plx32-eip-pnd ethernet/ip to profinet gateway module manufacturers, suppliers, ProSoft MVI56 MCM, MVI56E MCM pdf, MVI69-MCM, prosoft module, MVI56E-MCM, MVI69 MCM manual

Send Inquiry