The PLX32-EIP-PND is an industrial communication gateway engineered to bridge EtherNet/IP and PROFINET systems in automation environments where multi-protocol integration is required. It enables reliable, two-way data exchange between PROFINET controllers and EtherNet/IP-based devices without modifying existing control logic.
Designed as a self-contained, DIN-rail mountable unit, the PLX32-EIP-PND features dual Ethernet interfaces, each operating on an independent network segment. This architecture improves network separation, enhances stability, and simplifies integration across different industrial Ethernet infrastructures.
On the EtherNet/IP side, the PLX32-EIP-PND supports both implicit Class 1 I/O messaging and explicit Class 3 messaging, offering flexibility for real-time and non-real-time data handling. On the PROFINET side, the module functions as a PROFINET Class A device, ensuring compatibility with standard PROFINET controller implementations.
Hardware Specifications of PLX32-EIP-PND
| Item | Specification |
|---|---|
| Class 3 Server Connections | 5 |
| Supported PLC Types | PLC-2, PLC-5, SLC-500, CompactLogix, ControlLogix, MicroLogix |
| Supported Message Types | PCCC, CIP |
| Class 3 Client Connections | Connected: 2 / Unconnected: 1 |
| Class 1 I/O Connections | 8 |
| I/O Data Size (Input/Output) | 496 bytes / 496 bytes |
| Minimum RPI | 5 ms per connection |
| Supported Services | 0x4C – CIP Data Table Read; 0x4D – CIP Data Table Write |
| Commands per Client | Up to 100 (configurable type, IP address, register range, word/bit count) |
| Supported Command Sets | PLC-2/3/5 Basic, PLC-5 Binary, PLC-5 ASCII, SLC-500 |
| Device Class | Class A |
| Cyclic Data Capacity | 1,440 bytes Input / 1,440 bytes Output |
| Data Exchange Modes | Cyclic Real-Time (RT) and Acyclic |
| Nominal Voltage / Range | 24 VDC nominal (10–36 VDC) |
| Current Consumption | 300 mA @ 24 VDC; maximum 610 mA @ 10 VDC |
| Operating Temperature | –25 to +70 °C (–13 to +158 °F) |
| Storage Temperature | –40 to +80 °C (–40 to +176 °F) |
| Relative Humidity | 5% to 95% RH, non-condensing |
Contact US
Our address
32D floor, Guomao Building, No.388, Hubin South Road, Siming District, Xiamen
Phone Number/Whatsapp/Wechat
+86 18030132586
cn@mooreplc.com

Benefits and Features
1. ODVA Approved
2. PROFINET v2 certification with PROFINET Class A compliance
3. EtherNet/IP and PROFINET certifications ensure the device is compatible with their respective network
4. Field-tested with multiple PROFINET controllers from multiple vendors
5. Remotely view and diagnose EtherNet/IP and PROFINET networks
6. Embedded EDS AOP provided to allow for seamless integration to Studio 5000 and RSLogix 5000
7. Using EtherNet/IP I/O connections, no ladder programming is required
8. Multiple I/O connections to allow for increased throughput
9. Secure module configuration via module switch (v1.04 and greater)
10. Up to 10,000 16-bit registers can be used to exchange large amounts of data
Frequently Asked Questions
What is your return policy?
+
-
1) Defective Items: Report any defects within 3 days of delivery.
2) Return Condition: Items must be returned unused and in original packaging for refund/replacement.
3) Quality Issues: If an item has a manufacturing defect, you may return it within 7 days for a full refund or replacement.
How do you ensure product PLX32-EIP-PND quality?
+
-
Prosoft PLX32-EIP-PND undergoes strict quality inspection before shipment. In rare cases where issues arise, we will notify you promptly.
What is the primary role of the ProSoft PLX32-EIP-PND gateway?
+
-
The PLX32-EIP-PND is used to exchange data between EtherNet/IP devices and PROFINET controllers, allowing equipment on different industrial Ethernet networks to communicate without modifying existing control programs.
Does the gateway process data continuously during system operation?
+
-
Yes. Unlike startup-only components, the PLX32-EIP-PND operates continuously, managing cyclic and acyclic data transfers while the automation system is running.
Which industrial networks and controllers are supported by this module?
+
-
This gateway connects PROFINET controllers with EtherNet/IP-based PLCs and devices, making it suitable for mixed-protocol environments commonly found in modern industrial systems.
Recommendations
| IS200PDIOH1A | 51401594-200 | 133396-01 | 8440-2028 |
| 81001-451-62-R GU-D15 | 6DD1688-0AE0 | BWU1488 | NMFC03 |
| PTQ-PDPMV1 | XC5010C | F7541 | 330180-X2-05 |
| CC-PAON01 51410070-176 | 171CCS78000 | 810-099175-103 | 8163-4002 |
| 990-05-XX-01-00 MOD:165335-01 | CMON4108 | VME-LTNI-S4 B105-0102 | 8177-4002 |
| IC755CSW07CDACA-CG | 990-05-70-02-00 | 990-10-XX-01-05 | AAT141-S03 S2 |
| 330103-00-13-10-02-00 | 990-05-70-02-05 | ADV161-P50 S2 | PR6423/10R-040 |
| 990-05-70-02-01 | EC-BOM-G009HLA012 | 330910-14-19-10-02-00 | PR6424/000-130 CON021 |
| PR6424/011-010 CON021 | 80173-110-02 G651885C | 990-05-XX-03-05 147202-01 | SPW482-E3 S1 |
| PR6426/010-040 CON021/916-160 | BCU-22 3AUA0000110431 | 330910-014-19-10-02-00 | 1785-L60B/C |
| BCU-22 3AUA0000110431 | BCU-22 3AUA0000110431 | PR6423/002-130 CON021 | EC-BOM-G009HLA005 |
| BCU-22 3AUA0000110431 | EX10*MPS31 EX10-MPS31 | PR6423/003-110 CON021 | IIMGC01 SX-9000/64-8/B2 |
| EX10*MPS31 EX10-MPS31 | KJ3222X1-BK1 12P4705X062 SE4003S2B1 | BSFC-02C 3AXD50000011461 | NEYRPIC SL1000 V3 669187C/0572 |
Hot Tags: prosoft plx32-eip-pnd ethernet/ip to profinet gateway module, China prosoft plx32-eip-pnd ethernet/ip to profinet gateway module manufacturers, suppliers, ProSoft MVI56 MCM, MVI56E MCM pdf, MVI69-MCM, prosoft module, MVI56E-MCM, MVI69 MCM manual