Technical Specifications
MODULE TYPE
16-channel isolated TC/mV input
TC TYPES
J, K, E, B, R, S, T and N
mV RANGES
−100…+150 mV or −20…+80 mV
CHANNEL SETUP
TC/mV selected individually: CH1–CH16
INPUT LIMIT
±5 V; input resistance ≥1 MΩ
ACCURACY / UPDATE
±40 µV; 1 s update; CJC ±1 °C
SOURCE / WIRING
≤1000 Ω total; ±20 µV effect at 1000 Ω
WITHSTAND
Field/system 500 VAC; channels 200 VAC; 1 min
SINGLE-CARD TEST
1500 VAC for 1 minute
BURNOUT / SUFFIX
All channels together; confirm SM□ or SK□
PRODUCT DETAILS
Product Image Display
MODULE LABEL REFERENCE
Yokogawa AAT145 TC/mV input module label
16 channels · TC/mV input
Use the label and installed AAT145-SM□ or AAT145-SK□ terminal/cable arrangement together.
Confirm the complete module code
Read the full AAT145 label, including its suffix. The base model identifies a 16-channel TC/mV input module, but it does not confirm the installed connection hardware.
Match the field connection hardware
Check whether the installation uses ATD5S/ATD5D, AKB331 with AED5D, or the specified MIL-connector cable before removing a terminal or cable.
Record each channel signal type
AAT145 allows TC or mV selection individually for CH1–CH16. Record the installed input type and field allocation so the replacement is restored correctly.
Check the common burnout setting
Burnout is configured for all channels together, not one channel at a time. Confirm the existing setting before recommissioning the field inputs.
BEFORE REPLACEMENT
Replacement Checks Before Shutdown
Confirm the AAT145 identification
Verify the complete code and the 16-channel isolated TC/mV input function on the installed module before ordering.
Match the terminal or cable
Confirm ATD5S/ATD5D, AKB331 with AED5D, or the installed MIL-connector cable arrangement before transfer.
Record TC/mV selection by channel
The TC or mV input type is selected individually for CH1–CH16. Preserve the field allocation before connectors are moved.
Review the burnout setting
Burnout is set for all AAT145 channels together. Check the existing system response before returning the module to service.
TECHNICAL ANSWERS
Frequently Asked Questions
Is Yokogawa AAT145 an input or output module?
AAT145 is a 16-channel isolated TC/mV input module for FIO. It is not the ADV157 or ADV161 digital input module.
Which connection hardware is specified for Yokogawa AAT145?
Yokogawa lists ATD5S/ATD5D pressure-clamp terminal, AKB331 dedicated cable with AED5D terminal board, or a MIL-connector cable.
How many channels does Yokogawa AAT145 provide?
AAT145 provides 16 isolated TC/mV input channels for TC/mV field-input applications.
What should be checked before replacing Yokogawa AAT145?
Confirm the complete code, input function, TC/mV field arrangement, channel allocation and the installed terminal or cable hardware before removal.
Can the AAT145 connection arrangement be assumed from a digital input module?
No. Input and output modules can use different specified connection hardware. Check the AAT145 terminal or cable arrangement on the installed unit.
Why should field-input mapping be recorded for Yokogawa AAT145?
Correctly restoring input channel mapping is essential after a replacement. Mark terminals or connectors before disturbing the field interface.
CONTACT
Confirm AAT145 Before Ordering
Send the complete code, installed connection type, quantity and destination for a practical configuration check.
SALES CONTACT
Myrtle
WHATSAPP
+86 18950128464
EMAIL
sales5@askplc.com
ABOUT PLCEXPORT
Configuration review before dispatch
Sales and sourcing teams review the requested model, connection hardware, quantity and destination details before dispatch planning.
PLCEXPORT coordinated service support
Coordinated service support
Sales and sourcing work from the same requested model, quantity and destination details.
PLCEXPORT warehouse label verification
Warehouse label verification
Product labels and package details are checked against the requested order code before dispatch planning.
PLCEXPORT configuration review
Configuration review
Installed module and connection information can be reviewed before a replacement is planned.
PLCEXPORT global supply coordination
Global supply coordination
Availability and destination details are coordinated for the requested item.
RELATED REFERENCES
Recommended Models
Each internal link has been checked to a matching PLCEXPORT product page. Models in this five-product batch are not reused.
Other PLC & DCS Brands
Additional less-common controller and I/O references for maintenance searches; no external links are applied.
Fatek FBs-20MN
Fatek FBs-32MN
Fatek FBs-44MN
Fatek FBs-24XY
Haiwell H16S2T-e
Haiwell H16S0P-e
Haiwell H16S2P-e
Haiwell H24S2R-e
Horner HE-XE1E6
Horner HE-XC1E2
Horner HE-X2A
Horner HE-X2R
Unitronics USC-B10-RA28
Unitronics USC-B10-T42
Unitronics USC-B10-TA30
Unitronics USC-B10-TR22
ODOT CT-3734
ODOT CT-3744
ODOT CT-4154
ODOT CT-4158
SIGMATEK RO 041
SIGMATEK RO 051
SIGMATEK AI 022
SIGMATEK AI 022-1
ICP DAS LP-5231
ICP DAS WP-2241-CE7
ICP DAS LP-2241
ICP DAS WP-5000
Bachmann GIO212
Bachmann AIO208
Bachmann AIO216
Bachmann AIO208/SI

Hot Tags: yokogawa aat145 16-channel isolated tc/mv input module, China yokogawa aat145 16-channel isolated tc/mv input module manufacturers, suppliers, AAI141 S00 Analog IO Module, AAI841 H00 Yokogawa, AAI841 H03 I O, YOKOGAWA AAI141 S00, YOKOGAWA AAI841 H00 S2, YOKOGAWA AAI841 H03 S1

Send Inquiry