SIEMENS 6ED1055-1MD00-0BA2 LOGO! AM2 RTD Temperature Input Module

SIEMENS 6ED1055-1MD00-0BA2 LOGO! AM2 RTD Temperature Input Module

SIEMENS · LOGO! 8
6ED1055-1MD00-0BA2 · LOGO! AM2 RTD
Two-channel RTD expansion module for Pt100 and Pt1000 temperature sensors in LOGO! 8 control systems.
SALES MANAGER
Myrtle
Original new · One-year warranty · Stock 5000 · Delivery 3–5 days
Send Inquiry
Description
LOGO! 8 · LOGO! AM2 RTD

SIEMENS 6ED1055-1MD00-0BA2 LOGO! AM2 RTD Temperature Input Module

Two-channel RTD expansion module for Pt100 and Pt1000 temperature sensors in LOGO! 8 control systems. This page summarizes selection and replacement details from Siemens product data without substituting for the official installation documentation.

Technical specifications

Article-specific values are paraphrased from Siemens catalog data. Confirm the complete suffix before substitution.

Article number
6ED1055-1MD00-0BA2
Designation
LOGO! AM2 RTD
Supply
12/24 V DC · 10.8–28.8 V
Analog inputs
2 · 2- or 3-wire connection
Sensor types
Pt100 / Pt1000
Temperature range
−50 to +200 °C
Current consumption
Typically 30 mA
Mounting
35 mm DIN rail · 2 spacing units
Dimensions
35.5 × 90 × 58 mm
Protection / operation
IP20 · −20 to +55 °C
PLCEXPORT enquiry support
Part-number review · Delivery coordination
RTD MODULE SOURCING

Need two reliable RTD channels for a LOGO! panel?

Send the sensor type, required quantity and destination. Myrtle will check the exact AM2 RTD reference and return a clear quotation.

5000
Stock
1 Piece
MOQ
3–5 Days
Delivery
Myrtle · Sales Manager
WhatsApp · +86-18950128464Email · sales5@askplc.com
Payment: TT · Shipping port: Xiamen

Purpose and application areas

Temperature monitoring
Connects resistance thermometers for compact machine and building-control tasks.
Plant utilities
Tracks heating, cooling and process temperatures with Pt100/Pt1000 probes.
Retrofit panels
Adds two RTD channels without replacing the LOGO! 8 base module.

Frequently asked questions

Questions and answers are arranged vertically for quick reference.

+ Can 6ED1055-1MD00-0BA2 measure voltage or current signals?
No. This AM2 RTD variant is intended for Pt100 and Pt1000 resistance thermometers; voltage/current analog signals require a different LOGO! module.
+ Does 6ED1055-1MD00-0BA2 support two-wire sensors?
Yes. Siemens specifies two- or three-wire connection for its two RTD inputs.
+ What supply is used by 6ED1055-1MD00-0BA2?
It accepts 12 or 24 V DC across the official 10.8–28.8 V permissible range.
+ Where is 6ED1055-1MD00-0BA2 normally installed?
It clips onto a 35 mm DIN rail beside a compatible LOGO! 8 controller and occupies two spacing units.
ABOUT PLCEXPORT

Verification that starts with the full article number

Our team checks the complete Siemens reference, reviews practical stock status and keeps export communication clear from enquiry to dispatch.

 
One team, one reference
Coordinated automation support for customers worldwide.
 
Careful label review
Labels, interfaces and article numbers are checked carefully.
 
Responsive order support
Communication stays clear from enquiry through dispatch.

Recommended models

Published Honeywell and GE products from this website, followed by other recommended brands.

Honeywell

GE

Others · other recommended brands

Koyo D0-06DR
Horner HE-XE102
Unitronics V570-57-T20B
IDEC FC6A-C24R1CE
Fatek FBs-24MCR2-AC
Kinco K506-24AR
LS Electric XBC-DN32H
Saia PCD3.M5560
VIPA 315-4NE12
Bachmann MX207
WAGO 750-8212
Beckhoff CX9020

Request a 6ED1055-1MD00-0BA2 Quotation

Sales Manager · Myrtle

Send the exact model, quantity, destination and delivery requirement.

sales5@askplc.comWhatsApp +86-18950128464
Your name *
Email *
Company
Phone / WhatsApp
6ED1055-1MD00-0BA2, quantity, destination and technical requirements *
SEND REQUEST

Hot Tags: siemens 6ed1055-1md00-0ba2 logo! am2 rtd temperature input module, China siemens 6ed1055-1md00-0ba2 logo! am2 rtd temperature input module manufacturers, suppliers