Compact M10 × 1 3300 XL 8 mm probe for metric brackets: 70 mm threaded case, no smooth unthreaded extension, 0.5 m integral lead, standard ClickLoc connection and suffix 00 without the multiple-approval option.
A practical choice for an existing M10 × 1 bracket with restricted rear clearance and a verified 70 mm body requirement.
Confirm 0 mm unthreaded length, 70 mm case, two-locknut access and enough insertion range to establish the specified cold gap.
The 0.5 m integral lead is only one part of the tuned system; verify the extension-cable length and the connected 330180 Proximitor Sensor.
Standard ClickLoc connection without protector and no multiple-approval suffix; review moisture, oil and area-classification requirements.
The fields below prioritize the values buyers use for selection. Ratings not traceable to the exact model are intentionally marked for nameplate or project-document verification.
3300 XL 8 mm system
Retain every suffix
M10 × 1 metric thread; unarmored standard cable
Verify insertion and target geometry
Verify bracket and locknut position
Probe plus integral cable
Inspect before installation
Match site documentation
Official dimensional drawing
System component value
When correctly matched and installed
Under documented reference conditions
Verify with approved procedure
Flat target reference
Official system reference
All items must match
Measure the existing bracket-to-target depth and confirm a 70 mm M10 × 1 body provides enough insertion plus two-locknut adjustment.
Read the probe, extension-cable and Proximitor labels together; the short 0.5 m probe lead cannot be selected independently.
Inspect the unprotected code-02 ClickLoc joint for oil, moisture, dirt, looseness or damaged contacts before reuse.
After gapping, record static voltage, shaft position, channel indication and alarm status so the replacement can be compared with the previous baseline.
100% advance before shipping
Xiamen
3-5 days
New & original; availability confirmed before order
Carrier selection is arranged according to destination, shipment size and buyer requirements.
Use clear front, side, nameplate, connector and terminal photographs. The complete 330103-00-07-05-02-00 identity, revision, markings and physical condition must remain readable and be compared with the installed project.

No. Bently Nevada 330103-00-07-05-02-00 also fixes the 70 mm body, 0.5 m lead, code-02 ClickLoc connection and suffix-00 approval scope; every field must match the installed loop.
No. The integral lead of Bently Nevada 330103-00-07-05-02-00 is part of the calibrated proximity system and should not be cut, spliced or field-repaired; use the specified extension cable.
Bently Nevada 330103-00-07-05-02-00 should be investigated if the channel shows unstable gap voltage, intermittent readings when the cable moves, visible tip wear, crushed cable or contaminated ClickLoc contacts.
Keep Bently Nevada 330103-00-07-05-02-00 dry, protect the probe tip and connector, avoid tight cable coils and record the full label so the spare remains traceable to the correct loop.
For Bently Nevada 330103-00-07-05-02-00, provide the full nameplate, installed probe and connector photos, extension-cable and Proximitor labels, required condition, quantity and destination.
PLCEXPORT supports maintenance, engineering and procurement teams sourcing industrial automation components for active and legacy control systems.
We compare the complete 330103-00-07-05-02-00 identity, revision, connectors and visible condition before quotation.
Our team reviews the 330103-00-07-05-02-00 host system, slot, wiring and compatibility requirements.
The supplied 330103-00-07-05-02-00 markings, connectors and protective packaging are checked before dispatch.
Myrtle coordinates 330103-00-07-05-02-00 availability, documents, order details and worldwide delivery follow-up.
sales5@askplc.comWhatsApp
+86 18950128464
Hot Tags: bently nevada 330103-00-07-05-02-00 3300 xl 8 mm proximity probe, China bently nevada 330103-00-07-05-02-00 3300 xl 8 mm proximity probe manufacturers, suppliers, 330104 00 08 90 02 05 3300 XL 8 mm Proximity Probe, 330104 00 08 90 02 05 datasheet, 330180 51 05 Extension Cable, 330180-51-05, 330903 00 05 10 01 05 manual, 330903-00-05-10-01-05