Prosoft PLX32-EIP-MBTCP EtherNet/IP To Modbus TCP/IP Gateway Module

Prosoft PLX32-EIP-MBTCP EtherNet/IP To Modbus TCP/IP Gateway Module

Dimensions: 12.5x14x5cm
Weight: 0.24kg
Contact Sales Felicia for quotation and more info:
Mobile: +86 18030132586
Email: cn@mooreplc.com
Whatsapp(Wechat): +86 18030132586
Send Inquiry
Description
 

Contact Information

 
Sales Felicia Shi
Whatsapp +86 18030132586
Wechat +86 18030132586
Email cn@mooreplc.com
Mobile +86 18030132586

 

 

Products Description

 

 

   ProSoft Technolog's EtherNet/IP to Modbus TCP/IP communication gateway allows high-speed bi-directional data transfers between Rockwell Automation PACs and Schneider Electric PACs. Our Modbus TCP/IP driver features multiple client and server functionality, for faster data transmission. Two separate Ethernet ports allow each protocol to reside on separate subnets, allowing you to pass data between the two subnets without changing each device's IP address. In addition, the gateway includes an embedded EDS Add-On Profile, allowing for simplified integration and reduced commissioning time.

 

 

Product Parameters

 
Parameter Value
Power Supply 24 VDC nominal (10 – 36 VDC permitted) on +, –, GND terminals
Current Draw • 300 mA @ 24 VDC nominal• 610 mA max @ 10 – 36 VDC
Operating Temperature –25 °C to +70 °C (–13 °F to +158 °F)
Storage Temperature –40 °C to +80 °C (–40 °F to +176 °F)
Relative Humidity 5 % – 95 % RH, non-condensing
Dimensions (H × W × D) 5.38 × 1.99 × 4.38 in13.67 × 5.05 × 11.13 cm

product-1193-750

 

 

Features and Benefits

 

 

1. Two separate Ethernet ports allow each protocol to reside on separate subnets. This allows you to pass data between the two subnets without changing each device's IP address to be on the same subnet.

2. Data prioritization: Multiple I/O connections allow you to set RPIs for status and/or control data.

3. Includes an embedded EDS Add-On Profile, allowing for simplified integration and reduced commissioning time.

4. Gateway includes a SD card slot (SD card optional) for storing configuration files. This can be used for disaster recovery.

5. Secure module configuration via module switch (v1.04 and greater).

6. Up to 10,000 16-bit registers can be used to exchange large amounts of data.

 

 

Functional Specifications

 

 

Function Group Parameter Value / Description
EtherNet/IP Side Class 3 Server Connections 5
  Class 3 Client Connections 2 Connected + 1 Unconnected
  Class 1 I/O Connections 2
  I/O Connection Size 248 Bytes Input / 248 Bytes Output
  Max RPI 5 ms per connection
  Supported PLCs PLC-2, PLC-5, SLC-500, ControlLogix, CompactLogix, MicroLogix
  Message Types PCC & CIP
  CIP Services 0x4C Data Table Read, 0x4D Data Table Write
  Command List 100 commands per Client, fully configurable
  Command Sets PLC-2/3/5 Basic, PLC-5 Binary, PLC-5 ASCII, SLC-500
Modbus TCP Side Supported Clients 10
  Supported Servers 5 MBAP + 5 Encapsulated
  Client Commands 160 fully configurable
  Command Control Individual enable/disable, write-only-on-data-change
  Status Diagnostics Per-command error codes

 

 

FAQ

 
product-900-600

01.What is the primary function of the Prosoft PLX32-EIP-MBTCP Gateway Module?

The main function of the PLX32-EIP-MBTCP is to enable seamless communication between EtherNet/IP devices, such as Allen-Bradley PLCs, and Modbus TCP/IP devices, including I/O modules, sensors, and controllers.

02.Does the PLX32-EIP-MBTCP execute PLC logic or control operations?

No. The module does not execute PLC logic, control motors, or perform process calculations. Its sole purpose is protocol translation, ensuring that commands, data, and status signals are accurately passed between EtherNet/IP and Modbus TCP/IP devices.

03.Can this gateway be replaced or installed without affecting the PLC program?

Yes. One of the key advantages of the PLX32-EIP-MBTCP is that it can be installed or replaced independently without altering PLC code, HMI programs, or existing network configurations.

04.Where should the PLX32-EIP-MBTCP be physically installed?

The gateway is designed for industrial cabinet or DIN-rail mounting. It should be installed near the network devices it communicates with to minimize cable lengths and potential signal degradation.

 

 

Recommendations

 

 

1794-IM8 086444-005 WS18-3D430 51202324-100
3100-INUSA MVI56-ADMNET TCDEI-8D0P-DYU-G02 51202324-300
3100-LTQ MVI56-AFC 7379A31G04 51202329-402
3100-MDA4 WE18-3P430 DSTC404 57520001-DS 51202329-602
MVI56-GSC 51403645-400 SD822 3BSC610038R1 51202329-616
MVI56-MDA4 FSROC-EXP/EXP TU845 3BSE021447R1 51202329-732
3100-MDA16 DS200TBQAG1ABB AI895 3BSC690086R1 51202343-001
FBM1/37/43 P0400HH DS200TCPDG1BEC SD802F 3BDH000012R1 51304465-500
FBM2/36 P0500RG DS200TCQCG1BJF 330101-00-63-10-02-00 P-HC-BRC-30000000
FBM3A/33A P0500RU 4PP220.0571-45 CC-TDOB11 51308373-175 TB840 3BSE021456R1
FBM4/39/44 P0500RY 330101-00-28-05-02-00 KSML92S1450-W-MC1 IEC60945 TY801K01 3BSE023607R1

 

Hot Tags: prosoft plx32-eip-mbtcp ethernet/ip to modbus tcp/ip gateway module, China prosoft plx32-eip-mbtcp ethernet/ip to modbus tcp/ip gateway module manufacturers, suppliers, ProSoft MVI56 MCM, MVI56E MCM pdf, MVI69-MCM, prosoft module, MVI56E-MCM, MVI69 MCM manual

Send Inquiry