Official-base IC695PSD040 40 W supply for an RX3i Universal Backplane: 24 VDC nominal, 18–30 VDC input, one slot, no load sharing or redundancy. H marking requires nameplate verification.
New & original
One-year warranty
3–5 days
Condition: In stock
Send Inquiry
Description
GE PACSYSTEMS RX3i POWER

GE IC695PSD040H RX3i 24 VDC 40 W Power Supply

40 W, 24 VDC-input power supply for a PACSystems RX3i universal backplane; one-slot, non-redundant design.

New & original
One-year warranty
3–5 days
Condition: In stock
Request a quote

Description and purpose

The requested nameplate reads IC695PSD040H. GE's official product data identifies the base IC695PSD040 as a 40 W DC power supply for a PACSystems RX3i Universal Backplane. It occupies one slot and accepts 18–30 VDC, with 24 VDC nominal.

GE specifies no load sharing, no redundancy and no input-to-backplane isolation for the base IC695PSD040. The current official product page lists CA and LT suffix options but does not define H; therefore, confirm the full IC695PSD040H label and lifecycle record rather than assigning an unverified meaning to H.

Purchase verificationMatch the full IC695PSD040H nameplate to the official IC695PSD040 base specification: 24 VDC nominal input, 40 W total load and one-slot occupancy. Verify the H marking separately; do not infer its function or substitute another PSD/PSA model by wattage alone.

Technical specifications

Values summarized from GE product data for IC695PSD040 and the RX3i power-supply catalog. Final selection must follow the complete catalog number and installed system.

Requested marking
IC695PSD040H
Manufacturer
GE
Official base part
IC695PSD040
Product family
PACSystems RX3i
Product type
Universal-backplane DC power supply
Nominal input
24 VDC
Operating input range
18–30 VDC
Total load capacity
40 W
Backplane occupancy
1 slot
Input-to-backplane isolation
None
Load sharing / redundancy
No
LED indications
Power, P/S Fault, Overload, Overtemperature
Official suffix note
CA = conformal coating; LT = low temperature; H is not defined on the current official product page
POWER BUDGET REVIEW

Replacing an RX3i supply after an intermittent rack shutdown?

Send Myrtle clear photos of the complete IC695PSD040H label, the input-terminal markings and LEDs, together with the RX3i backplane model and installed module list. We will check the official 18–30 VDC input window, 40 W power budget and one-slot fit, and flag the H suffix for separate lifecycle verification.

Sales Manager: MyrtleConfiguration review before quotation

Applications

RX3i machine controllers, process skids, material-handling systems and infrastructure panels supplied from a 24 VDC control source where a 40 W non-redundant universal-backplane supply is specified.

Ordering information

PaymentT/T
PortXiamen
Lead time3–5 days
ConditionIn stock
BUYER QUESTIONS

FAQ about IC695PSD040H

Can GE IC695PSD040H be used in a redundant power arrangement?
No. GE lists IC695PSD040 as a 40 W supply without load sharing or redundancy. If the application requires redundancy, review the approved multi-purpose supply architecture rather than paralleling this model.
What input voltage should be available for IC695PSD040H?
The official range is 18–30 VDC with 24 VDC nominal. Measure voltage at the supply terminals under load and check wiring drop, not just the upstream source.
Is IC695PSD040H isolated from the RX3i backplane?
No. GE lists no input-to-backplane isolation for IC695PSD040. Review grounding and DC-source architecture when troubleshooting noise or ground-potential problems.
How do I know whether 40 W is enough for my RX3i rack?
Add the consumption of the CPU, communication and I/O modules using official data, then compare the required backplane loads with the supply ratings. Leave engineering margin instead of relying on the number of occupied slots.
Does the H suffix on IC695PSD040H have a published meaning on the current product page?
No meaning for H is stated on the current official IC695PSD040 product page. The page identifies CA for conformal coating and LT for low temperature. Keep the complete IC695PSD040H marking in the request and verify it from the label, installed BOM and official lifecycle record before accepting another revision.
What information should accompany an IC695PSD040H quotation?
Send the complete IC695PSD040H label, RX3i backplane model, installed module list, measured input voltage, LED state, fault symptoms, quantity and destination. Because H is not defined on the current public product page, a sharp nameplate photo is essential.

About PLCEXPORT

PLCEXPORT supports automation maintenance and project teams with model identification, practical compatibility checks and international supply coordination. Our China team reviews labels and order details before dispatch preparation.

 
Technical discussion
Our team compares system context, suffixes and interface details before quotation.
 
PLCEXPORT team
Colleagues coordinate identification, commercial follow-up and shipping details.
 
Packing inspection
Product identity and package condition are checked during order preparation.
 
China operations
Local coordination supports sourcing, documentation and international dispatch.

Need a documented compatibility check?

Send the complete IC695PSD040H identification, quantity, destination and installed-system details to Myrtle. We will review the request before quotation and help identify any suffix, terminal, firmware or configuration point that still needs confirmation.

EmailWhatsApp

Hot Tags: ge ic695psd040h rx3i 24 vdc 40 w power supply, China ge ic695psd040h rx3i 24 vdc 40 w power supply manufacturers, suppliers, GE Fanuc IC695CEP001, GE Fanuc IC695CPE302, GE IC695CPE302, IC695CEP001, IC695CEP001 CEP Carrier Module, IC695CPE302 CPU module

Send Inquiry