Emerson KJ1501X1-BC2 DeltaV System Dual DC Power Supply

Emerson KJ1501X1-BC2 DeltaV System Dual DC Power Supply

Emerson · System Dual DC Power Supply
KJ1501X1-BC2
DeltaV system power supply for 12 VDC or 24 VDC input, with output capacity dependent on input mode and operating temperature.
Condition
Confirm available condition
MOQ
1 piece
Warranty
1 year
Availability
Confirm current stock
Weight
Confirmed with quotation
Dimensions
159 × 41 × 107 mm (H × W × D)
Origin
United States (pictured unit)
Ships from
Xiamen, Fujian, China
SALES MANAGER
Cristina
Send the model, quantity and destination for a faster quotation.
Send Inquiry
Description
12 / 24 VDC system power

KJ1501X1-BC2 at a Glance

The KJ1501X1-BC2 powers compatible DeltaV controller and LocalBus hardware. It accepts a nominal 12 VDC or 24 VDC supply and provides 12 VDC, 5 VDC and 3.3 VDC outputs. Its 12 VDC output current depends on the selected input mode and cabinet temperature, so an existing installation should be checked against the full BC2 ratings before replacement.

Emerson Specifications and Ordering Details

Product code
KJ1501X1-BC2
Module function
DeltaV System Dual DC Power Supply
12 VDC input range
11.4 to 12.6 VDC
24 VDC input range
20.4 to 28.8 VDC
12 VDC output with 12 VDC input
13 A maximum to 60 °C; 10 A maximum to 70 °C
12 VDC output with 24 VDC input
4.5 A maximum to 60 °C; 3 A maximum to 70 °C
Logic outputs
5 VDC at 2 A; 3.3 VDC at 2 A
Combined logic-output limit
10 W total for the 5 VDC and 3.3 VDC outputs
Operating temperature
-40 to +70 °C
Relative humidity
5 to 95%, noncondensing
Airborne contaminants
ISA-S71.04-1985 Class G3
Mounting
Either slot of a compatible 2-wide Power/Controller Carrier
Input connection
2-wire DC input
Maintenance
No user-serviceable parts; calibration not required
Replacement
Remove system power before removal or insertion
Weight
Confirmed with quotation for the offered unit
Dimensions
159 × 41 × 107 mm (H × W × D; power-supply housing)
Country of origin
United States (pictured unit)
Ships from
Xiamen, Fujian, China
Minimum order
1 piece
Warranty
1-year supplier warranty; coverage confirmed in quotation

Confirm the complete order code and product label before purchase or replacement.

Buyer and Engineering Checks

Match the complete supply identity

Confirm KJ1501X1-BC2, assembly number, hardware revision and carrier arrangement against the installed supply.

Identify the input mode

Check whether the site uses nominal 12 VDC or 24 VDC and verify the measured input against the corresponding allowable range.

Calculate each output load

Check the 12 VDC load at the expected cabinet temperature, then check the combined 10 W budget for the 5 VDC and 3.3 VDC outputs separately.

Review wiring and replacement procedure

Confirm input polarity, alarm connections, system power arrangements and the approved isolation procedure before disconnecting the supply.

KJ1501X1-BC2 Product View

Emerson KJ1501X1-BC2

Identification checklist

Match the complete model and order code, product label, terminal layout, power requirements and platform compatibility. A similar enclosure does not prove interchangeability.

Typical Applications

Replacement of an existing BC2 system supply in a compatible DeltaV installation.
Powering DeltaV controller and LocalBus electronics from an engineered DC supply arrangement.
Maintenance planning where input mode, output loading and temperature derating must be matched.

KJ1501X1-BC2 FAQ

What does KJ1501X1-BC2 do?

It is a DeltaV system DC/DC power supply for compatible controller and LocalBus hardware.

Can it operate from either 12 VDC or 24 VDC?

Yes. The documented ranges are 11.4-12.6 VDC and 20.4-28.8 VDC respectively. Output limits differ between the two modes.

Does the 10 W rating include the 12 VDC output?

The stated 10 W limit is the combined budget for the 5 VDC and 3.3 VDC outputs. Check the 12 VDC output against its separate current rating.

Is BC2 automatically interchangeable with BC1 or BC3?

Compare the exact supply and its ratings before substitution. The historical manual gives BC1 a narrower 24 VDC input range; BC3 also has different output ratings.

Can this supply be removed while energized?

The BC2 instructions require system power to be removed before the unit is removed or inserted. Follow the site's isolation procedure.

What are the ordering terms?

The minimum order is one unit, with a one-year seller warranty. Confirm the required revision, condition, stock and lead time when requesting a quotation.

Company and Export Support

Moore Automation company 1Moore Automation company 2Moore Automation company 3Moore Automation company 4

We support industrial automation sourcing with model verification, product photography and export coordination. Send the model, quantity, destination and requested delivery date for a focused quotation.

Request a KJ1501X1-BC2 Quotation

For a faster response, include quantity, destination, required delivery date and any replacement or compatibility notes.

WhatsApp Quote
KJ1501X1-BC2

Hot Tags: emerson kj1501x1-bc2 deltav system dual dc power supply, China emerson kj1501x1-bc2 deltav system dual dc power supply manufacturers, suppliers, KJ1611X1 FD1 user manual, KJ1611X1FD1, KJ1611X1-FD1, KJ2005X1 BA1 12P4375X012, KJ2005X1 BA1 12P4375X012 Emerson, KJ2005X1-BA1

Send Inquiry