Bently Nevada 9200-06-05-10-00 9200 Seismoprobe Velocity Transducer
Two-wire velocity transducer with 0° ±100° orientation, 10 Hz minimum frequency, terminal-block top mount, M10×1 base and no approvals.
What matters when specifying 9200-06-05-10-00
Orientation code
06 = 0° ±100°.
Frequency limit
10 Hz (600 cpm) minimum.
Connection
05 = terminal-block top mount, no cable.
Mounting base
10 = circular M10×1 stud.
Description and purpose
Documented purpose
9200-06-05-10-00 measures machine-casing vibration for continuous monitoring or periodic diagnostic measurements.
Replacement caution
Install on a suitable bearing housing or machine casing. Match orientation, base, wiring, load and frequency response; poor mounting can distort amplitude and frequency response.
Technical specifications
The fields below prioritize the values buyers use for selection. Ratings not traceable to the exact model are intentionally marked for nameplate or project-document verification.
Bently Nevada, a Baker Hughes business
9200 Seismoprobe Velocity Transducer
9200-06-05-10-00
Match every suffix and revision on the supplied label
Two-wire velocity Seismoprobe
Continuous or periodic measurement
20 mV/mm/s (500 mV/in/s)
With documented load and orientation
10 Hz to 1 kHz
+0/−3 dB typical for option 06
05
Terminal-block top mount; no cable
10
Circular M10×1 stud
00
No approvals
Planning a 9200-06-05-10-00 replacement
Full identity record
Photograph the complete 9200-06-05-10-00 label, revision, connectors and installed position before removal.
System compatibility
Confirm the 9200-06-05-10-00 host system, mating hardware, cable or terminals and approved project documentation.
Physical inspection
Check 9200-06-05-10-00 mounting, connector condition, cable routing, grounding and environmental exposure.
Commissioning evidence
After installing 9200-06-05-10-00, verify every affected measurement, alarm, diagnostic or protection path against the approved procedure.
Applications
Casing vibration
Measures absolute bearing-housing vibration.
Continuous monitoring
Feeds compatible monitoring instrumentation.
Periodic diagnostics
Supports portable or diagnostic measurements.
Metric mounting
Uses circular M10×1 stud base.
Ordering information
100% advance before shipping
Xiamen
3-5 days
New & original; availability confirmed before order
Carrier selection is arranged according to destination, shipment size and buyer requirements.
Product image and identification notes
Confirm the exact 9200-06-05-10-00 in the photographs
Use clear front, side, nameplate, connector and terminal photographs. The complete 9200-06-05-10-00 identity, revision, markings and physical condition must remain readable and be compared with the installed project.

FAQ about 9200-06-05-10-00
What is 9200-06-05-10-00 used for?
9200-06-05-10-00 is two-wire velocity transducer with 0° ±100° orientation, 10 Hz minimum frequency, terminal-block top mount, M10×1 base and no approvals. It must be selected as part of the documented Bently Nevada system, not by appearance alone.
Which official product family includes 9200-06-05-10-00?
9200-06-05-10-00 belongs to 9200 Seismoprobe Velocity Transducer. The complete family manual and installed-system drawing should be checked before quotation or replacement.
Which specifications matter most when selecting 9200-06-05-10-00?
For 9200-06-05-10-00, verify the complete order code, mechanical execution, cable or terminal arrangement, system length or channel configuration, approvals and the exact receiving hardware.
Can 9200-06-05-10-00 replace a visually similar Bently Nevada item?
9200-06-05-10-00 should replace another item only after its full suffix, revision, interfaces, mounting, electrical characteristics and host-system compatibility have been matched.
What should be photographed before removing 9200-06-05-10-00?
For 9200-06-05-10-00, photograph the complete nameplate, all suffixes, front and side views, connectors or terminals, installed position, adjacent hardware and cable routing.
What installation checks are required for 9200-06-05-10-00?
Before installing 9200-06-05-10-00, isolate the machine as required, inspect mating hardware, verify grounding and wiring, preserve configuration evidence and follow the official service procedure.
How should 9200-06-05-10-00 be commissioned?
After installing 9200-06-05-10-00, restore the system in the approved sequence and prove the affected signal, speed, vibration, position, diagnostic and alarm functions appropriate to the application.
What information is needed for a 9200-06-05-10-00 quotation?
For a 9200-06-05-10-00 quotation, send the full label, host-system model, existing configuration, clear photographs, quantity, destination, required condition and any certificate or approval requirements.
About PLCEXPORT
PLCEXPORT supports maintenance, engineering and procurement teams sourcing industrial automation components for active and legacy control systems.
Model verification
We compare the complete 9200-06-05-10-00 identity, revision, connectors and visible condition before quotation.
Technical coordination
Our team reviews the 9200-06-05-10-00 host system, slot, wiring and compatibility requirements.
Inspection and packing
The supplied 9200-06-05-10-00 markings, connectors and protective packaging are checked before dispatch.
Customer support
Myrtle coordinates 9200-06-05-10-00 availability, documents, order details and worldwide delivery follow-up.
Planning a 9200-06-05-10-00 replacement?
sales5@askplc.comWhatsApp
+86 18950128464
Recommended models
Bently Nevada
HIMA
Hot Tags: bently nevada 9200-06-05-10-00 9200 seismoprobe velocity transducer, China bently nevada 9200-06-05-10-00 9200 seismoprobe velocity transducer manufacturers, suppliers, 330103 06 25 10 02 00 3300 XL 8 mm Proximity Probes, 330104 00 08 90 02 05 datasheet, 330104-00-08-90-02-05, 330180 51 05 Extension Cable, bently nevada 3300 series and 3300 xl proximity probe, Bently Nevada 330104 00 08 90 02 05