S7-200 SMART Expansion Cable Technical Parameters

6ES7288-6EC01-0AA0 is the Siemens one-metre I/O expansion cable used when S7-200 SMART expansion modules cannot remain in a single horizontal row. It provides the documented connection for a two-tier arrangement while keeping module expansion on the native S7-200 SMART bus.

Product typeI/O expansion cable
Cable length1 m
SystemSIMATIC S7-200 SMART
Layout purposeTwo-tier expansion arrangement
Installation pointCPU-to-first EM or between two EMs
Maximum per CPU systemOne expansion cable
Net weightApprox. 0.08 kg
Article number6ES7288-6EC01-0AA0

Selection and Integration Notes

Check the system layout

Confirm the installed CPU and EM sequence before separating the modules into two rows.

Plan the one-metre route

Allow a smooth bend radius and keep the cable away from sharp edges and high-noise wiring.

Secure the connector heads

Use strain relief in vibrating installations and verify both ends are fully seated.

Inspect before power-up

Check the article number, connector condition and module order before energizing the station.

Actual Product Detail

SIEMENS 6ES7288-6EC01-0AA0 product detail

6ES7288-6EC01-0AA0 hardware and identification view

Correct selection boundary

Use only one expansion cable in a CPU system. Support the cable and connector heads so vibration, movement or pulling force cannot loosen the module connection.

Two-row control panelsSpace-constrained cabinetsS7-200 SMART expansionMachine retrofit layouts

Verification Sequence

  1. 01Power down the CPU and connected expansion modules.
  2. 02Mount the two module rows and verify the intended module sequence.
  3. 03Connect the cable between the CPU and first EM, or between two EMs.
  4. 04Apply strain relief, restore power and confirm every expansion module is detected.

S7-200 SMART Expansion Cable FAQ · Interactive

What is the cable length?

Siemens specifies a cable length of 1 metre.

How many cables may be used in one CPU system?

Siemens states that only one expansion cable is allowed per S7-200 SMART CPU system.

Where can the cable be installed?

It can be installed between the CPU and the first expansion module, or between two expansion modules.

Is strain relief recommended?

Yes. In vibrating environments the connector heads should be secured so the connection cannot gradually loosen.

Is this a PROFINET or Ethernet cable?

No. It is the dedicated S7-200 SMART I/O expansion cable for the module bus.

What should be included in an inquiry?

Send the complete MLFB, quantity, destination and the installed CPU and expansion-module sequence.