SIEMENS 6ES7288-1SR60-0AA1 SIMATIC S7-200 SMART CPU SR60

SIEMENS 6ES7288-1SR60-0AA1 SIMATIC S7-200 SMART CPU SR60

SIMATIC S7-200 SMART · RELAY CPU
6ES7288-1SR60-0AA1
High-density AC CPU with 36 inputs, 24 relay outputs and 50 KB memory
36 DI · 24 V DC24 relay DQ · 2 A50 KB memory
AVAILABILITY
In Stock · Original New · 1-Year Warranty
Get a Quote
Sales Manager: Cristina  ·  sales3@mooreplc.com  ·  WhatsApp +86 180 2071 4662 ↗
Send Inquiry
Description

SR60 Hardware Record

CPU SR60 is the high-density relay member in this S7-200 SMART group. Its sixty onboard digital points reduce the number of signal modules required for larger machines, while the 50 KB memory provides more room for structured sequences, alarms and communication handling. The AC supply and relay outputs make the unit especially relevant to conventional control cabinets.

Article number
6ES7288-1SR60-0AA1
CPU designation
CPU SR60 AC/DC/Relay
Onboard inputs
36 digital inputs, 24 V DC
Onboard outputs
24 relay outputs, 2 A
Supply voltage
85–264 V AC, 47–63 Hz
Memory
50 KB program/data memory
Programming
STEP 7 Micro/WIN SMART
Network
Ethernet/PROFINET + RS485
Mounting
Standard DIN rail
Dimensions
175 × 100 × 81 mm
Weight
Approx. 611.5 g
Additional point
Web-server support

Product Detail & Identification

SIEMENS 6ES7288-1SR60-0AA1 model label and hardware detail
Actual product and identification detail

Dense field wiring without a large expansion stack

Thirty-six inputs and twenty-four relay outputs let one base CPU supervise several machine sections. The wider enclosure must be allowed for during panel replacement, and relay commoning should be reviewed carefully because the larger point count can tempt installers to combine unrelated voltage groups.

Power format
AC/DC/Relay
Output technology
Relay
CPU family
S7-200 SMART
Web access
Supported by 0AA1 generation

SR60 I/O Architecture

Signal capacity36 digital inputs, 24 V DC are integrated in the base CPU. Input filtering and high-speed counter assignments must be configured for the actual sensor signals.
Output behavior24 relay outputs, 2 A provide the local actuation layer. Load type, current, common grouping and protection must be reviewed before energizing the panel.
Program resources50 KB program/data memory supports machine sequencing, communications, diagnostics and PID functions. Optional microSDHC use depends on the service procedure.

Communications & Integration

Ethernet and PROFINET

The isolated RJ45 interface supports 10/100 Mbit/s Ethernet and S7 communication. PROFINET controller or I-Device capabilities depend on firmware; verify roles, update time and device count in the active project.

RS485 serial channel

The integrated RS485 port supports serial integration up to 187.5 kbit/s. Addressing, termination, shield bonding and the selected protocol must match every field device.

SR60 High-Density Startup

1 · Identify
Confirm the 175 mm panel space and terminal accessibility.
2 · Wire
Divide the 24 relay outputs into clearly documented load groups.
3 · Protect
Calculate inrush for all simultaneously commanded actuators.
4 · Validate
Test web, PROFINET and RS485 access before automatic operation.

Where SR60 Fits

The I/O and output technology of CPU SR60 make it a practical choice for the following control duties. Final selection must still consider safety architecture, analog requirements, expansion count and environmental limits.

Large conveyor sections
Multi-pump utility plants
Complex packing lines
Centralized machine auxiliaries
Production test systems
High-I/O retrofit panels

SR60 integration notes for high-density relay I/O

SR60 concentrates sixty digital points in the base CPU. That density can reduce module count, but it also demands disciplined terminal planning, panel-space checks and staged commissioning so that a large field-wiring bundle remains understandable.

Confirm the physical retrofit envelope

The 175 × 100 × 81 mm body is wider than the smaller SMART CPUs. Check DIN-rail space, wire-duct clearance, connector access and the bend radius of existing conductors before selecting SR60 as a replacement. A drawing that shows only rail length can miss the practical space needed to land thirty-six inputs and twenty-four outputs without pulling tightly across neighbouring equipment.

Break thirty-six inputs into diagnostic groups

Divide the input list by machine section and reserve meaningful addresses for emergency-chain feedback, mode selection, material detection and actuator confirmation. Grouped documentation helps technicians see whether a fault belongs to one field supply or one physical area. It also makes it easier to decide which signals should use configurable filtering or high-speed counter resources instead of ordinary scan-based processing.

Engineer the twenty-four relay outputs as load banks

A dense output count increases the chance that several actuators will switch together. Calculate coil inrush, branch protection and common-conductor loading for the intended sequence. Keep voltage groups separated and identify them at the terminal strip. Apply suitable suppression to inductive devices, and avoid using the 2 A resistive rating as a substitute for checking the real electrical category of each contactor or valve.

Use the 50 KB resource for maintainable logic

Fifty kilobytes gives SR60 more space for station-oriented function blocks, alarm text handling and communication routines. Use that capacity to improve structure rather than duplicate unlabelled networks. During a migration, preserve symbol tables, comments, retentive data definitions and tested initial values. A program that fits is not automatically a program that can be maintained during a production stop.

Stage network and serial verification

Test the Ethernet/PROFINET path separately from the RS485 channel. Record the device name and IP plan, then verify any remote devices or HMI exchanges before enabling production commands. For serial equipment, check topology, termination and station settings at the ends of the bus. High I/O density should not hide the fact that one incorrect network parameter can disable several machine sections at once.

Receive SR60 by article number and terminal evidence

The correct ordering reference is 6ES7288-1SR60-0AA1. Compare that complete number with the CPU label, confirm the AC supply and relay output format, and photograph the terminal areas before disconnecting an existing panel. Because this controller handles many conductors, a labelled before-and-after record is especially valuable when resolving a discrepancy during startup.

Building an auditable SR60 high-density cabinet

Start with a conductor map, not a point total

Sixty onboard points can make an equipment list look simple while the physical terminal work becomes complex. Create a conductor map that relates each of the thirty-six input wires and twenty-four output wires to a cabinet terminal, field device, voltage source and functional zone. Mark spare points separately from commissioned points. This document becomes the common reference for drawing review, wire checks, software addressing and final acceptance instead of relying on several lists that may drift apart.

Divide input power by fault-containment area

The input count is large enough that one field-supply fault could obscure several unrelated machine symptoms if distribution is not considered carefully. Plan protected 24 V DC branches around the equipment layout and indicate the relevant common at every input group. During testing, prove loss and restoration of each branch while watching the online input image. The objective is not merely to make all inputs turn on, but to understand which part of the machine is affected when a protection device opens.

Calculate relay demand from the operating sequence

A static list of twenty-four loads does not show which coils operate together. Review the actual sequence and identify the worst simultaneous command, including restart and fault-recovery states. Compare contactor and solenoid inrush with branch protection, common conductors and the applicable relay contact data. If an interface relay is required for a difficult load, show it explicitly in both the output schedule and maintenance drawing so that future replacement does not bypass the intended protection.

Make terminal access part of the enclosure study

The 175 mm CPU width is only the starting dimension. Add the room needed to release terminal blocks, read markings, route the larger wire bundle and reach adjacent expansion hardware. Check whether the wire duct can accept the conductor quantity without crushing or sharp bends. For retrofit work, a scaled photograph or cabinet sketch often exposes obstacles that a clean schematic does not show, such as door equipment, trunking covers or a neighbouring power device.

Organise the 50 KB program around machine ownership

Use the larger memory resource to separate station logic, alarm evaluation, communications and common services into maintainable program areas. Every output should have a traceable command path and every important permissive should produce a useful diagnostic state. Before migration, identify retentive data, startup assumptions and any value that an operator expects to survive a power cycle. A structured project shortens troubleshooting time much more than simply filling the available memory with additional networks.

Treat web, PROFINET and serial access as three tests

The Ethernet connector, PROFINET role and RS485 channel solve different integration tasks. Confirm the CPU address and device name from the network plan, prove the intended Ethernet partners, and then test the serial bus with its own baud rate, address and termination checks. If the web feature is enabled, document who may access it and from which automation segment. Passing one ping test does not validate the rest of the communication design.

Prepare a controlled rollback before production startup

Keep the verified original CPU, complete project backup and recorded parameter set available until SR60 acceptance is finished. Define the conditions that would require a rollback, who authorises it and how field wiring will be returned safely. This is particularly important for a high-density replacement because several zones may depend on one base unit. A written rollback plan prevents hurried decisions if one communication partner or actuator bank behaves differently under live production conditions.

Close the job with evidence that can be reused

Archive the 6ES7288-1SR60-0AA1 label photograph, firmware record, final project, I/O force-test sheet, network settings and annotated terminal schedule. Add the measured supply voltage and any interface-relay details that were introduced during commissioning. These records allow the next technician to distinguish a field fault from a configuration issue without repeating the original survey, and they provide purchasing with a reliable reference for a future spare.

FAQ · 6 Questions

What is 6ES7288-1SR60-0AA1?
It is a Siemens SIMATIC S7-200 SMART CPU SR60 with 36 digital inputs, 24 v dc and 24 relay outputs, 2 a.
Which programming software is used for CPU SR60?
Siemens specifies STEP 7 Micro/WIN SMART. Project version and firmware compatibility should be checked before downloading a replacement CPU.
What supply does SR60 require?
SR60 uses 85–264 V AC, 47–63 Hz. The installed power circuit, protective device and field commons must match this format.
Are the outputs suitable for high-speed pulses?
Relay contacts are intended for ordinary switching, not high-speed pulse generation. Choose a compatible ST transistor CPU when pulse outputs are required.
Does SR60 support industrial communications?
The CPU includes Ethernet/PROFINET and an RS485 interface. Available roles and device counts depend on the firmware and project configuration.
What should be checked before replacement?
Compare the complete article number, supply/output format, terminal assignment, firmware, expansion modules, network settings and the backed-up Micro/WIN SMART project.

SR60 Cross-Reference Library

SIEMENS · Published Models

SIEMENS 6ES7288-1SR20-0AA1 CPU SR20 · SR60 library 01SIEMENS A5E00444860 Industrial Control · SR60 library 02SIEMENS 6DD3460-0AC0 Control Module · SR60 library 03SIEMENS 6ES7531-7KF00-0AB0 Analog Input · SR60 library 04SIEMENS 6GK1143-0TA00 Ethernet Processor · SR60 library 05SIEMENS 6DD1660-0AE0 Communication Interface · SR60 library 06SIEMENS 6DS1832-8AA EEPROM Memory · SR60 library 07SIEMENS 6ES5304-3UB11 Expansion Interface · SR60 library 08SIEMENS R15E02A186 Automation Electronics · SR60 library 09SIEMENS 39RTMCAN 16207-61/10 RTD Module · SR60 library 10SIEMENS 6DP1900-8AA Process Control · SR60 library 11SIEMENS 6DD1606-2AC0 Automation Processor · SR60 library 12SIEMENS 7KG8000-8AB20/FF Measurement Unit · SR60 library 13SIEMENS 7UT5121-4CB01-0AA0/LL Relay · SR60 library 14SIEMENS 6DS1606-8BA Binary Output · SR60 library 15SIEMENS K3R072 528605 Display Driver · SR60 library 16SIEMENS 6DS1412-8RR Analog Controller · SR60 library 17SIEMENS 6DS1411-8RR Control Module · SR60 library 18SIEMENS 16182-1-3 Bus Expander · SR60 library 19SIEMENS 6DS1121-8BB Automation Module · SR60 library 20

Others · Selected Models

AMG 2151
64-825-0045-4
AN100
4744R
4743
1-XR4-433C
T6831A
ABB MT701.2
HIMA F8652X
WOODWARD 5466-1035

PLC EXPORT SR60 Support

PLC EXPORT technical sales meetingPLC EXPORT customer support team

PLC EXPORT supports SR60 enquiries with complete article-number review, label comparison and shipment coordination for international automation customers. Our team checks complete article numbers, photographed labels, condition and requested quantities before quotation and shipment coordination.

Clear identification · Responsive quotation · Reliable supply

Email CristinaWhatsApp ↗

REQUEST AN SR60 QUOTATION

Subject: SIEMENS 6ES7288-1SR60-0AA1 SIMATIC S7-200 SMART CPU SR60
Sales Manager: Cristina  ·  sales3@mooreplc.com  ·  +86 180 2071 4662 ↗
Quick
Quote

Hot Tags: siemens 6es7288-1sr60-0aa1 simatic s7-200 smart cpu sr60, China siemens 6es7288-1sr60-0aa1 simatic s7-200 smart cpu sr60 manufacturers, suppliers, 6ES7 315 2AH14 0AB0, 6ES7 315 2AH14 0AB0 Siemens, 6ES7317 2EK14 0AB0 Siemens, siemens, Siemens 6ES7 315 2AH14 0AB0, Siemens 6ES7317 2EK14 0AB0

Send Inquiry