SIEMENS 6ES7241-1CH32-0XB0 RS422/485 Communication Module
A serial communication module that connects an S7-1200 station with RS422/RS485 field devices through a 9-pin D-sub socket.
|
RS422 / RS485
One configurable serial interface |
Protocol Ready
Freeport · Modbus RTU · USS |
Long-Distance Link
Up to 1,000 m cable length |
Serial connectivity for equipment that still matters
The CM 1241 provides a practical route between an S7-1200 controller and serial devices such as energy meters, barcode readers, variable-speed drives, weighing terminals, remote controllers, and vendor-specific instruments.
Its configurable RS422/RS485 interface supports open character-based communication and established industrial protocols, allowing older field equipment and newer compact PLC systems to exchange data without unnecessary architecture changes.
Technical Specifications
|
Article number
|
6ES7241-1CH32-0XB0
|
|
Product designation
|
CM 1241 RS422 / RS485
|
|
Physical interface
|
1 × RS422/485 (X.27), 9-pole D-sub socket
|
|
Rated supply
|
24 V DC (20.4–28.8 V permissible)
|
|
Current consumption
|
220 mA maximum from 5 V DC backplane bus
|
|
Power loss
|
1.1 W typical
|
|
Cable length
|
Up to 1,000 m
|
|
Integrated drivers
|
Freeport, ASCII library, Modbus RTU master/device, USS library
|
|
Freeport telegram length
|
Up to 1 kbyte
|
|
Diagnostics
|
Supported; LED status indication
|
|
Protection / temperature
|
IP20; −20 °C to +60 °C horizontal installation
|
|
Dimensions
|
30 × 100 × 75 mm (W × H × D)
|
|
Approx. weight
|
155 g
|
Values are based on the Siemens technical data for article 6ES7241-1CH32-0XB0. Confirm the current manual, CPU compatibility, wiring, termination, and communication settings before commissioning.
|
SERIAL PART SEARCH SUPPORT
A legacy serial link should not delay the whole line. |
Share the complete part number, required quantity, destination, and target date. Myrtle can help check availability and confirm the practical order details for difficult automation communication parts. Request a QuoteEmail Myrtle |
![]() |
CM 1241 · 9-PIN D-SUB
Compact serial communication beside the CPUThe slim 30 mm module mounts alongside the S7-1200 CPU and provides a dedicated RS422/RS485 connection for serial field communication. Status indication supports commissioning and diagnostics, while the D-sub socket gives a clear physical connection point for the configured network. Selection check
Article number · interface standard · protocol · cable and termination Image source: Siemens SiePortal product page. |
|
COMMUNICATION TASKS
Purpose & FunctionsConnect
Link serial meters, drives, readers, terminals, and controllers. Translate
Exchange data through Freeport, Modbus RTU, or USS workflows. Extend
Support point-to-point links up to 1,000 m. Maintain
Keep established serial equipment connected to an S7-1200 system. |
INDUSTRIAL USE
Application Areas
|
FAQ
|
01
What is the SIEMENS 6ES7241-1CH32-0XB0 used for?It adds an RS422/RS485 serial interface to a SIMATIC S7-1200 station for communication with drives, meters, readers, controllers, and other serial devices. |
02
Which protocols does the 6ES7241-1CH32-0XB0 support?Siemens lists Freeport, Modbus RTU master/device, and library-based ASCII and USS communication options. |
|
03
Is the 6ES7241-1CH32-0XB0 a standalone controller?No. It is a CM 1241 communication module used with a compatible S7-1200 CPU; the CPU runs the user program. |
04
How long can the cable be for the 6ES7241-1CH32-0XB0?The official technical data specifies a maximum point-to-point cable length of 1,000 m. Actual design should still consider baud rate, cable type, termination, and EMC conditions. |
|
05
Can the 6ES7241-1CH32-0XB0 act as a Modbus master and device?Yes. Its integrated protocol drivers support both Modbus RTU master and Modbus RTU device operation. |
06
What should be checked before replacing a 6ES7241-1CH32-0XB0?Confirm the full article number, CPU compatibility, RS422/485 wiring, termination, protocol settings, station address, baud rate, and the saved project configuration. |
|
Part No.: 6ES7241-1CH32-0XB0
|
Payment: TT
|
Port: Xiamen
|
|
Lead time: 3–5 days
|
Stock: 5000
|
MOQ: 1
|
|
Product weight: 0
|
![]() |
PART-NUMBER SUPPORT WITH A HUMAN CHECK
Practical sourcing for connected automation systemsPLCEXPORT supports plant teams and integrators sourcing PLC, DCS, safety, communication, and process-control spares across mixed-generation installations. For serial communication modules, the team pays particular attention to the full article number, interface type, protocol requirement, and delivery scope-details that matter when an established field network must remain serviceable.
|
![]() |
SERIAL MODULE INQUIRY
Send the interface details with the part numberAdding the required protocol, device count, cable length, and destination gives Myrtle a clearer basis for checking the requested item and delivery options. |
Recommended Models
ABB
HIMA
Others · Other Recommended Brands
|
|
|
|
|
|||||
|
|
|
|
|
Hot Tags: siemens 6es7241-1ch32-0xb0 simatic s7-1200 cm 1241 rs422/485 communication module, China siemens 6es7241-1ch32-0xb0 simatic s7-1200 cm 1241 rs422/485 communication module manufacturers, suppliers, 6ES7 315 2AH14 0AB0, 6ES7 315 2AH14 0AB0 CPU 315 2 DP, 6ES7317 2EK14 0AB0 Central processing unit, 6ES7317-2EK14-0AB0, Siemens 6ES7 315 2AH14 0AB0, Siemens 6ES7317 2EK14 0AB0