HONEYWELL FC-TSDO-0824 Digital Output Module

HONEYWELL FC-TSDO-0824 Digital Output Module

— Part No.: FC-TSDO-0824 (Digital Output Module)
— Manufacturer: Honeywell
— Product Type: Digital Output Module — Series Compatibility: Honeywell Distributed Control and PLC Systems
— Availability: In Stock
— Country of Manufacture: United States (USA)
— Sales Manager: Silver
— Email: sales1@askplc.com
— Phone (WhatsApp): +86-18020714492
— WeChat: +86-18020714492
Send Inquiry
Description

 

HONEYWELLFC-TSDO-08247x6x58cm008kg10
 

Products Description

The FC-TSDO-0824 Digital Output Module provides precise and reliable control of discrete actuators, relays, and other field devices within Honeywell distributed control and PLC systems. It converts control signals from the CPU or controller into switchable outputs, enabling operators to manage processes, alarms, and equipment actuation in real time. The module is engineered for industrial conditions, with protection against electrical noise, temperature fluctuations, and vibration.

Installed within an I/O rack or control panel, this module allows centralized management of multiple digital outputs, reducing wiring complexity while providing clear status indications. Its architecture supports continuous operation and facilitates integration with diagnostic and supervisory systems.

 

 

Characteristics

 

♦ Provides discrete digital outputs compatible with Honeywell PLC/DCS systems
♦ High-speed switching ensures accurate control of field devices
♦ Industrial-grade construction withstands vibration, EMI, and temperature extremes
♦ Integrated status indicators allow real-time monitoring of output states
♦ Reduces wiring complexity by consolidating multiple outputs into a single module
♦ Facilitates diagnostics and maintenance with clear channel separation

 

Applications

 

This digital output module is commonly used in industrial automation settings that require controlled switching of field devices. Typical applications include:

♦ Activating alarms, indicators, or sirens in process plants
♦ Driving relay coils for motor starters or solenoid valves
♦ Implementing safety interlocks in critical systems
♦ Coordinating distributed control of pumps, fans, and actuators
♦ Serving as the output interface in high-density I/O panels

It is suitable for chemical, petrochemical, power generation, and manufacturing environments where reliability and precise timing are essential.

 

Parameter Table

 

Parameter Specification
Model Number FC‑TSDO‑0824
Product Type Safe Digital Output Module (FTA)
Number of Output Channels 8 channels
Nominal Output Voltage 24 VDC typical
Maximum Output Voltage Up to 36 VDC (IEC 1010)
Maximum Continuous Current per Channel 1.5 A max
Response Time < 1 ms
Isolation Galvanically isolated channels
Communication Interface Modbus RTU / RS‑485
Operating Temperature –20 °C to +70 °C
Storage Temperature –40 °C to +85 °C
Humidity Range 5 % to 95 % RH non‑condensing
Mounting Type DIN‑rail or panel mount
Protection Rating IP65 (dust/water resistant)
DIN Rail Compatibility TS32 / TS35 × 7.5

Contact Information

 

For pricing, availability, or technical consultation regarding this model, please contact our sales team:

 

【Sales Manager】

 

Silver

 

【WhatsApp】

+86-18020714492

product-900-500
 

【Email】

sales1@askplc.com

 

【WeChat】

+86-18020714492

 

 FAQ 

 

Q1 What types of devices can this digital output module control?
It can drive relays, solenoids, alarms, indicators, and other discrete field devices compatible with 24 V DC or system-specific voltage.

Q2 How is signal integrity maintained in electrically noisy environments?
The module incorporates optical or electrical isolation and uses industrial-grade connectors to ensure reliable output switching.

Q3 Can it support rapid switching of multiple outputs simultaneously?
Yes, the module is designed for high-speed, simultaneous switching of all digital channels without performance degradation.

Q4 How are output states monitored?
LED indicators for each channel provide real-time visibility of energized or de-energized states, assisting operators and maintenance teams.

Q5 Is any calibration required?
No calibration is required; routine inspection of connectors and load devices is sufficient for long-term operation.

 

You may also like

SIEMENS 6SY8102-0LA03 TRICONEX 8110
SIEMENS 6XV1830-0EH10 200M TRICONEX 8300A
SIEMENS 700-443-0TP01 S7-TCP/IP 200-8000-01 TRICONEX 8310
SIEMENS 7KG6000-8AE/CC TRICONEX 8311
SIEMENS 7KG7000-8AA/BB TRICONEX 8312
SIEMENS 7KG8000-8AB20/FF TRICONEX 9563-810
SIEMENS 7RE2800-0CA00 TRICONEX 9662-110
SIEMENS 7TL4400-0/CC TRICONEX 9662-610
SIEMENS 7TM3401-3/CC C73451-A280-B252 TRICONEX 9668-110
SIEMENS 7TR6021-1/BB TRICONEX 9674-810

 

catalog 3

Hot Tags: honeywell fc-tsdo-0824 digital output module, China honeywell fc-tsdo-0824 digital output module manufacturers, suppliers, 10105 2 1 manual, 10215 2 1 meaning, 10006 2 1 manual, honeywell, 10006 21 battery module, Honeywell 10215 2 1

Send Inquiry