HIMA HIMatrix F2 DO 16 02 Safety Relay Output Remote I/O

HIMA HIMatrix F2 DO 16 02 Safety Relay Output Remote I/O

HIMA HIMATRIX
HIMA HIMatrix F2 DO 16 02 Safety Relay Output Remote I/O
HIMatrix safety remote I/O with 16 relay outputs up to 30 V AC / 60 V DC and an integrated two-port 100BASE-TX safeethernet switch.
New & original
One-year warranty
3-5 days
Send Inquiry
Description
HIMA HIMATRIX

HIMA HIMatrix F2 DO 16 02 16-channel safety relay output remote I/O

HIMatrix safety remote I/O with 16 relay outputs up to 30 V AC / 60 V DC and an integrated two-port 100BASE-TX safeethernet switch.

New & original
One-year warranty
3-5 days
PRODUCT AT A GLANCE

What matters when specifying HIMatrix F2 DO 16 02

Complete identity

Match every character in HIMatrix F2 DO 16 02, including suffixes and revision markings.

Installed-system basis

HIMatrix F2 DO 16 02 compatibility depends on the documented host system, slot and wiring.

Customer selection check

Confirm 16 relay outputs, maximum 30 V AC / 60 V DC contact potential, connected loads, safeethernet settings and 24 V DC supply.

Replacement planning

Record labels, connectors, settings and diagnostics before removing HIMatrix F2 DO 16 02.

FUNCTION AND USER GUIDANCE

Description and purpose

Documented purpose

F2 DO 16 02 provides sixteen relay outputs for distributed safety applications. HIMA certification identifies relay contact potentials up to 30 V AC or 60 V DC with safeethernet communication through an integrated two-port switch.

Replacement caution

Do not confuse F2 DO 16 02 with transistor-output F2 DO 16 01. Confirm relay contact load, protective circuitry, contact potential, safeethernet configuration and proof-test requirements.

OFFICIAL-DOCUMENT-BASED SUMMARY

Technical specifications

The fields below prioritize the values buyers use for selection. Ratings not traceable to the exact model are intentionally marked for nameplate or project-document verification.

Product type

HIMatrix safety remote I/O

F2 DO 16 02

Output type

Relay outputs

Do not confuse with F2 DO 16 01

Output channels

16

Verify contact and terminal allocation

Contact potential

Up to 30 V AC / 60 V DC

Per HIMA certification

Network

2-port 100BASE-TX switch

safeethernet

Safety capability

SIL 3 / Category 4 / PL e

CENELEC SIL 4 documented for certified application

Rated supply

20.4 to 28.8 V DC

Verify complete execution

Ambient temperature

0 to 50 °C

IECEx data for F2 DO 16 02

Installation

Remote output station

Document addressing and resource

Buyer check

Relay load, contact voltage, network, firmware and proof test

All must match

INSTALLATION CHECKS

Planning a HIMatrix F2 DO 16 02 replacement

Nameplate record

Photograph the complete HIMatrix F2 DO 16 02 label and all revision markings.

Connector control

Label every plug, terminal and cable before removal; preserve keying and grounding.

Project verification

Compare the host rack, channel allocation, supply and configuration with approved drawings.

Commissioning

Use the manufacturer procedure to verify diagnostics and every affected signal or safety function.

USER APPLICATIONS

Applications

Safety relay outputs

Switches low-voltage safety circuits.

Shutdown final elements

Controls documented relay-interfaced loads.

Distributed safety

Places output switching near field equipment.

Maintenance replacement

Restores a verified F2 DO 16 02 station.

COMMERCIAL DETAILS

Ordering information

PAYMENT

100% advance before shipping

PORT

Xiamen

DELIVERY TIME

3-5 days

CONDITION

New & original; availability confirmed before order

 
LOGISTICS PARTNERS

Carrier selection is arranged according to destination, shipment size and buyer requirements.

DHL
Express
UPS
Worldwide
FedEx
Priority
TNT
International
ARAMEX
Logistics
SF Express
Asia network
IMAGE AND NAMEPLATE REVIEW

Product image and identification notes

PHOTO VERIFICATION

Confirm the exact HIMatrix F2 DO 16 02 in the photographs

Use clear front, side, nameplate, connector and terminal photographs. The complete HIMatrix F2 DO 16 02 identity, revision, markings and physical condition must remain readable and be compared with the installed project.

 
Full nameplate
Front and side view
Connector detail
Installed position
HIMatrix F2DO1602 1
BUYER QUESTIONS

FAQ about HIMatrix F2 DO 16 02

Q1

What is HIMatrix F2 DO 16 02 used for?

 

HIMatrix F2 DO 16 02 is a HIMA HIMatrix remote I/O device with 16 safety-related relay outputs. Its exact duty must be confirmed against the installed-system documentation.

Q2

Which system uses HIMatrix F2 DO 16 02?

 

HIMatrix F2 DO 16 02 belongs to HIMA HIMATRIX. Confirm the controller, rack or remote-I/O execution before ordering.

Q3

What specifications matter when selecting HIMatrix F2 DO 16 02?

 

For HIMatrix F2 DO 16 02, verify confirm 16 relay outputs, maximum 30 v ac / 60 v dc contact potential, connected loads, safeethernet settings and 24 v dc supply. Do not select a replacement from appearance alone.

Q4

Can HIMatrix F2 DO 16 02 replace a similar module directly?

 

HIMatrix F2 DO 16 02 should only replace another unit after the full model, revision, host-system compatibility, connector arrangement and project approval have been confirmed.

Q5

Can HIMatrix F2 DO 16 02 be removed while energized?

 

HIMatrix F2 DO 16 02 must only be removed under the approved isolation, stored-energy and safety procedure for the installed system.

Q6

How should HIMatrix F2 DO 16 02 be commissioned?

 

After installing HIMatrix F2 DO 16 02, verify seating, supply, configuration and diagnostics, then function-test every affected channel under the approved procedure.

Q7

What photographs are required for HIMatrix F2 DO 16 02?

 

For HIMatrix F2 DO 16 02, provide the complete nameplate, front and side views, connector area, installed slot, adjacent hardware and terminal labels.

Q8

What should be sent for a HIMatrix F2 DO 16 02 quotation?

 

Send the full HIMatrix F2 DO 16 02 identity, revision, host system, slot, connector and wiring photographs, required condition, quantity and destination.

ABOUT PLCEXPORT

About PLCEXPORT

PLCEXPORT supports maintenance, engineering and procurement teams sourcing industrial automation components for active and legacy control systems.

Model verification

Model verification

We compare the complete HIMatrix F2 DO 16 02 identity, revision, connectors and visible condition before quotation.

Technical coordination

Technical coordination

Our team reviews the HIMatrix F2 DO 16 02 host system, slot, wiring and compatibility requirements.

Inspection and packing

Inspection and packing

The supplied HIMatrix F2 DO 16 02 markings, connectors and protective packaging are checked before dispatch.

Customer support

Customer support

Myrtle coordinates HIMatrix F2 DO 16 02 availability, documents, order details and worldwide delivery follow-up.

CONFIGURATION SUPPORT

Planning a HIMatrix F2 DO 16 02 replacement?

Send the complete HIMatrix F2 DO 16 02 label, installed-system details, connector and terminal photographs, required condition, quantity and destination. Myrtle will compare identity and compatibility points before quotation.
Email Myrtle
sales5@askplc.com
WhatsApp
+86 18950128464

Hot Tags: hima himatrix f2 do 16 02 safety relay output remote i/o, China hima himatrix f2 do 16 02 safety relay output remote i/o manufacturers, suppliers, HIMA F35 011 Controller, HIMA HIMatrix F35 011, HIMA HIMatrix F35 011 Safety Related, HIMA HIMatrix F60 MI, HIMatrix F35 011, HIMatrix F60 MI 24 01

Send Inquiry