GE IC200CHS006 VersaMax Communications Carrier

Carrier base that provides DIN-rail mounting, backplane communication and field wiring for a compatible VersaMax fieldbus communications module.

New & originalOne-year warranty3–5 daysCondition: In stock
Send Inquiry
Description
GE VERSAMAX CARRIER

GE IC200CHS006 VersaMax Communications Carrier

Carrier base that provides DIN-rail mounting, backplane communication and field wiring for a compatible VersaMax fieldbus communications module.

Description and purpose

IC200CHS006 is the dedicated VersaMax communications carrier used beneath a fieldbus communications module. It forms the mechanical mounting point, carries the backplane connection and presents the field-wiring interface needed by the installed communications module.

For maintenance work, confirm the mating communications module, terminal arrangement and available DIN-rail space rather than selecting the carrier by appearance alone. The carrier can occupy any suitable VersaMax station position, subject to the system layout.

Purchase verification

Send a clear nameplate and connector photo. We will compare the full suffix and installed interface before quotation.

Technical specifications

Concise values checked against GE VersaMax Modules, Power Supplies and Carriers User Manual GFK-1504Q. Final selection must follow the complete order code and installed system.

Model
IC200CHS006
Manufacturer
GE
Country of origin
United States
Product family
VersaMax
Product type
Communications carrier
Compatible equipment
VersaMax fieldbus communications modules
Mounting
35 mm DIN rail; panel mounting may be added
Dimensions
66.8 mm W × 133.4 mm H
Station position
Any suitable VersaMax slot
Functions
Mounting, backplane communication and field wiring
Grounding note
Use a conductive, corrosion-resistant grounded DIN rail
CONFIGURATION SUPPORT

Replacing a communications carrier without rewiring surprises?

Send Myrtle the complete IC200CHS006 label, installed communication-module number, terminal and connector photos, station layout, quantity and destination. We will compare the carrier and mating-module arrangement before quotation.

Sales Manager: Myrtle
Model and suffix review
Compatibility check before quotation

Applications

Fieldbus-node carrier replacementConfirm the installed wiring, revision and system configuration before replacement.
VersaMax remote I/O maintenanceConfirm the installed wiring, revision and system configuration before replacement.
Panel and DIN-rail retrofit projectsConfirm the installed wiring, revision and system configuration before replacement.

Ordering information

Payment
T/T
Port
Xiamen
Lead time
3–5 days
Condition
In stock

Product image and identification notes

IC200CHS006

Check the carrier and mating module together

Use the product photo to compare the side latch, DIN-rail foot, terminal area and mating backplane connector. A carrier may look correct while its installed communication module or wiring interface differs. Request a clear front, side and connector photo before approving a replacement.

Buyer tip: include a photo showing both the IC200CHS006 carrier and the communication module installed above it.
BUYER QUESTIONS

FAQ about IC200CHS006

How can I confirm IC200CHS006 will accept my existing VersaMax communication module?

Provide the communication-module catalog number and a photo of the mating backplane area. IC200CHS006 is intended for VersaMax fieldbus communications modules, but the exact module and terminal arrangement should be checked before a shutdown replacement.

Can IC200CHS006 be mounted only on DIN rail?

It snaps onto a 35 mm DIN rail. GE also recommends panel mounting when the installation needs maximum vibration and shock resistance, so confirm the enclosure environment before installation.

Why does grounding matter when installing IC200CHS006?

The DIN rail is part of the station grounding arrangement. Use an electrically grounded, conductive, unpainted and corrosion-resistant rail to avoid unreliable chassis grounding.

Can IC200CHS006 be placed in any position of a VersaMax station?

The carrier may be located in a suitable station position, but the final location must remain consistent with the station design, wiring reach and the requirements of the communication module mounted on it.

What should I photograph before requesting an IC200CHS006 quote?

Send the full label, side profile, terminal area, backplane connector and the mounted communication module. These views help rule out a visually similar but incompatible carrier.

Does IC200CHS006 include the fieldbus communication module?

No. It is the communications carrier. Confirm whether your purchase request is for the carrier only or for a carrier-plus-module assembly so the quotation matches the maintenance scope.

ABOUT PLCEXPORT

Automation-parts support from China

PLCEXPORT helps maintenance and project teams identify active and legacy PLC/DCS components through label review, configuration checks and practical shipment coordination.

PLCEXPORT technical discussion
Technical discussion
Our team reviews nameplates, interfaces and application details before quotation.
PLCEXPORT team
PLCEXPORT team
Sales and technical colleagues coordinate model checks and order follow-up.
PLCEXPORT inspection
Inspection and packing
Visible labels, connectors and package condition are checked during preparation.
PLCEXPORT company activity
Customer-focused support
Clear communication helps buyers manage urgent and difficult-to-source requirements.
QUICK RESPONSE

Need a compatibility check before ordering?

Send Myrtle the complete model, suffix, quantity, installed-system details and destination. Clear photos help us narrow down a suitable supply option.

Hot Tags: ge ic200chs006 versamax communications carrier, China ge ic200chs006 versamax communications carrier manufacturers, suppliers

Send Inquiry