GE IC200ALG264L 15-Channel Current Input Module

GE IC200ALG264L 15-Channel Current Input Module

GE VERSAMAX ANALOG I/O

GE IC200ALG264L 15-Channel Current Input Module

Fifteen-channel single-ended VersaMax analog input module for 4–20 mA or 0–20 mA current signals.

New & originalOne-year warranty3–5 daysCondition: In stock
Send Inquiry
Description
GE VERSAMAX ANALOG I/O

GE IC200ALG264L 15-Channel Current Input Module

Fifteen-channel single-ended VersaMax analog input module for 4–20 mA or 0–20 mA current signals.

Description and purpose

IC200ALG264L accepts fifteen single-ended current inputs in one group. The default range is 4–20 mA; installing the range-selection jumper changes operation to 0–20 mA.

For process-loop replacement, verify the L suffix, selected range, jumper position, transmitter power arrangement and common wiring. Open-wire diagnostics are available only in 4–20 mA mode, which affects how loop faults are detected.

Purchase verification

Send a clear nameplate and connector photo. We will compare the full suffix and installed interface before quotation.

Technical specifications

Concise values checked against GE VersaMax Modules, Power Supplies and Carriers User Manual GFK-1504Q. Final selection must follow the complete order code and installed system.

Model
IC200ALG264L
Manufacturer
GE
Country of origin
United States
Product family
VersaMax Analog I/O
Product type
Current input module
Channels / wiring
15 single-ended channels; one group
Input ranges
4–20 mA default; 0–20 mA with jumper
Resolution
15-bit
Input impedance
100 Ω
Update rate
7.5 ms
Input filter
24 Hz ±20%
Accuracy at 25 °C
±0.3% typical; ±0.5% maximum
Accuracy over 0–60 °C
±1.0% maximum
Backplane current
100 mA maximum at 5 VDC
Isolation
250 VAC continuous field-to-logic/frame; no channel isolation
Diagnostics
Open-wire in 4–20 mA mode; internal-power loss
CONFIGURATION SUPPORT

Seeing unstable or open analog loops after a module change?

Send Myrtle the IC200ALG264L label, range-jumper photo, loop drawings, transmitter type and power arrangement, measured current, channel symptoms, quantity and destination. We will review the range and common wiring before quotation.

Sales Manager: Myrtle
Model and suffix review
Compatibility check before quotation

Applications

4–20 mA process transmittersConfirm the installed wiring, revision and system configuration before replacement.
Multi-loop current monitoringConfirm the installed wiring, revision and system configuration before replacement.
VersaMax analog retrofitConfirm the installed wiring, revision and system configuration before replacement.

Ordering information

Payment
T/T
Port
Xiamen
Lead time
3–5 days
Condition
In stock

Product image and identification notes

IC200ALG264L new

Confirm the range jumper, terminal map and L suffix

Ask for clear photos of the IC200ALG264L label, range-selection jumper, terminal numbering and connector condition. Fifteen single-ended channels share one group, so the common and transmitter wiring must be compared carefully with the existing loop drawings.

Buyer tip: if open-wire alarms are required, confirm the module is operated in the 4–20 mA range.
BUYER QUESTIONS

FAQ about IC200ALG264L

How do I select 4–20 mA or 0–20 mA on IC200ALG264L?

The module defaults to 4–20 mA. Installing the specified range-selection jumper changes it to 0–20 mA, so photograph and record the jumper before replacement.

Why does IC200ALG264L open-wire detection work on some loops but not others?

The documented open-wire diagnostic applies in 4–20 mA mode. It is not available in the same way when the module is configured for 0–20 mA.

Are the 15 IC200ALG264L channels isolated from each other?

No. They are single-ended channels in one group with no channel-to-channel isolation. Review common potential and grounding to prevent measurement errors.

What input resistance will the transmitter see on IC200ALG264L?

The specified input impedance is 100 ohms. Include that burden, cable resistance and any other loop devices when checking available transmitter compliance voltage.

How quickly does IC200ALG264L update all process inputs?

The documented update rate is 7.5 ms with a 24 Hz input filter. The control strategy and PLC scan add further delay to the end-to-end response.

What should I send to confirm an IC200ALG264L replacement?

Provide the complete L-suffix label, jumper position, loop drawings, current range, transmitter power arrangement, grounding/common scheme, channel symptoms and connector photos.

ABOUT PLCEXPORT

Automation-parts support from China

PLCEXPORT helps maintenance and project teams identify active and legacy PLC/DCS components through label review, configuration checks and practical shipment coordination.

PLCEXPORT technical discussion
Technical discussion
Our team reviews nameplates, interfaces and application details before quotation.
PLCEXPORT team
PLCEXPORT team
Sales and technical colleagues coordinate model checks and order follow-up.
PLCEXPORT inspection
Inspection and packing
Visible labels, connectors and package condition are checked during preparation.
PLCEXPORT company activity
Customer-focused support
Clear communication helps buyers manage urgent and difficult-to-source requirements.
QUICK RESPONSE

Need a compatibility check before ordering?

Send Myrtle the complete model, suffix, quantity, installed-system details and destination. Clear photos help us narrow down a suitable supply option.

Hot Tags: ge ic200alg264l 15-channel current input module, China ge ic200alg264l 15-channel current input module manufacturers, suppliers

Send Inquiry