Allen-Bradley 1756-IB16D Diagnostic DC Input Module

Allen-Bradley 1756-IB16D Diagnostic DC Input Module

Allen-Bradley · 16-Point Diagnostic 12/24 V DC Input Module
1756-IB16D
Sixteen-point diagnostic 12/24 V DC sinking input module with field-fault monitoring for ControlLogix systems.
Condition
Original new unit; confirm current availability
MOQ
1 piece
Warranty
1 year
Availability
Confirm current stock
Weight
Verify product label and offered-unit documentation
Dimensions
Verify product label and official series-specific drawing
Origin
Malaysia (manufacturer listing; confirm offered-unit label)
Ships from
Xiamen, Fujian, China
SALES MANAGER
Cristina
Send the model, quantity and destination for a faster quotation.
Send Inquiry
Description
16 DIAGNOSTIC INPUTS · OPEN-WIRE DETECTION · 36-PIN TERMINAL BLOCK

1756-IB16D at a Glance

1756-IB16D adds open-wire diagnostics and diagnostic timestamping to sixteen 12/24 V DC sinking inputs. Its four groups and 36-pin terminal arrangement are different from the standard 1756-IB16 and must be checked before replacement.

Buyer and Engineering Checks

Confirm the diagnostic requirement

Verify that open-wire monitoring is required and that the field-device leakage behavior supports reliable diagnostics.

Review leakage-resistor wiring

Select the correct external leakage resistor for the supply voltage when required by the official wiring diagram.

Match the 36-pin terminal map

Check the four input groups, group commons and required 1756-TBCH or 1756-TBS6H removable terminal block.

Configure diagnostics correctly

Set filter time, change of state, open-wire diagnostics, diagnostic latching and electronic keying in the supported Studio 5000 project.

Allen-Bradley Specifications and Ordering Details

Product family
ControlLogix Bulletin 1756 I/O
Module type
Diagnostic DC digital input module
Inputs
16 diagnostic inputs; 4 points per group
Voltage category / range
12/24 V DC sink; 10 to 30 V DC operating range; 24 V DC nominal
Input delay
Off-to-on: 340 µs nominal / 1 ms max plus filter; on-to-off: 740 µs nominal / 4 ms max plus filter
Diagnostic functions
Open-wire detection, configurable fault latching and diagnostic change-of-state behavior
Diagnostic timing
Diagnostic timestamp accuracy: ±1 ms
Backplane draw
150 mA at 5.1 V; 3 mA at 24 V; 0.84 W total
Power / thermal dissipation
5.8 W maximum at 60 °C / 19.78 BTU per hour
Input-state limits
Off: 5 V and 1.5 mA maximum; on: 2 mA at 10 V minimum and 13 mA at 30 V maximum
Isolation
250 V continuous basic insulation, inputs-to-backplane and group-to-group; no individual input isolation within a group
Terminal / mounting
36-pin 1756-TBCH or 1756-TBS6H RTB required separately; one chassis slot
Operating environment
0 to 60 °C; open-style enclosure
Lifecycle
Active; verify hardware series and current lifecycle before quotation

Confirm the complete order code and product label before purchase or replacement.

Typical Applications

Discrete input circuits where open-wire fault identification is important.
Process and machine monitoring requiring point-level diagnostic information.
Maintenance-sensitive 24 V DC field-input systems.
ControlLogix installations requiring timestamped diagnostic events.

1756-IB16D Product View

Allen-Bradley 1756-IB16D

Identification checklist

Match the complete model and order code, product label, terminal layout, power requirements and platform compatibility. A similar enclosure does not prove interchangeability.

1756-IB16D FAQ

What diagnostics does the 1756-IB16D provide?

Rockwell documents open-wire detection, diagnostic timestamping, configurable fault latching and diagnostic change-of-state handling.

Can the 1756-IB16D directly replace a 1756-IB16?

Not automatically. The IB16D uses different input grouping and a 36-pin terminal block, so wiring, terminal hardware, filters, diagnostics and project configuration must be reviewed.

Is the 1756-IB16D a safety input module?

No. It is a diagnostic standard ControlLogix input module. Safety functions require appropriately certified safety I/O and a validated GuardLogix architecture.

What information speeds up a 1756-IB16D quotation?

Send the exact 1756-IB16D catalog number, quantity, destination, required delivery date and any replacement or compatibility notes.

Is availability shown live on this page?

No. Current availability, supplied condition, included accessories and lead time are confirmed in the written quotation.

What warranty is offered?

A one-year supplier warranty is offered, subject to the written quotation and warranty terms.

Company and Export Support

Moore Automation company 1Moore Automation company 2Moore Automation company 3Moore Automation company 4

We support industrial automation sourcing with model verification, product photography and export coordination. Send the model, quantity, destination and requested delivery date for a focused quotation.