Products Overview
The Allen Bradley 1756-OA8D ControlLogix Digital I/O Module is a high-performance Diagnostic AC Output Module designed for the ControlLogix platform. Featuring eight 120V AC diagnostic output channels, this module provides reliable switching control along with enhanced output monitoring capabilities.
It operates within a voltage range of 74–132V AC and delivers a maximum output current rating of 1 Amp per point at 30°C (0.5 Amps at 60°C), with total module current up to 8 Amps at 30°C.
| Parameter | Specification |
|---|---|
| Module Type | Diagnostic AC Output Module |
| Outputs | 8 Diagnostic Outputs |
| Voltage | 120 Volts AC |
| Operating Voltage Range | 74–132 Volts AC |
| Maximum Output Current Rating (Per Point) | 1 Amp @ 30°C; 0.5 Amps @ 60°C |
| Maximum Output Current Rating (Per Module) | 8 Amps @ 30°C; 4 Amps @ 60°C |
| Power Dissipation (Max) | 5.3 Watts @ 60°C |
| Backplane Current at 5 Volts | 175 mA |
| Backplane Current at 24 Volts | 250 mA |
| Removable Terminal Block(s) | 1756-TBNH, 1756-TBSH |
| Isolation Voltage | 50 Volts Continuous |
| Enclosure | None |

Diagnostic Specifications

Short Trip (Minimum): 12 A for 500 μs
No Load Detection: Off-state detection only
Output Verification: On-state detection only
Pulse Test: Configurable maximum pulse width and maximum time delay from zero-cross
Field Power Loss (Zero Cross Detection): Detects at 25V peak minimum using firmware phase-locked loop
Time Stamp Accuracy of Diagnostics: ±1 ms
Advantages
One of the key strengths of the Allen Bradley 1756-OA8D module is its integrated diagnostic capability. With on-state output verification, off-state no-load detection, and field power loss detection at 25V peak, the module continuously monitors output circuit health. The short-trip protection of 12A for 500 μs helps prevent damage during fault conditions.
Additionally, timestamped diagnostics with ±1 ms accuracy provide precise event tracking for troubleshooting. These features significantly reduce downtime, simplify maintenance, and enhance operational transparency, making the module ideal for critical industrial processes that demand high availability and fast fault identification.
FAQ
1. What is the main function of the 1756-OA8D module?
The 1756-OA8D is a Diagnostic AC Output Module designed for the ControlLogix platform. It provides eight 120V AC output channels with built-in diagnostic capabilities to monitor output status, detect wiring faults, and improve system reliability.
2. What voltage range does the 1756-OA8D support?
The module operates at 120 Volts AC with an operating voltage range of 74–132 Volts AC, ensuring compatibility with standard industrial AC control circuits.
3. Does the 1756-OA8D support short-circuit protection?
Yes. The module has a minimum short-trip rating of 12 Amps for 500 microseconds, helping protect outputs during fault conditions.
4. What diagnostic features are included?
The module supports off-state detection for no-load conditions and on-state detection for output verification. It also provides zero-cross detection and timestamped diagnostics with ±1 ms accuracy.
Recommendations
| 100M1554 | 1MRK000161-AAR01 |
| 76683-90 | YPG108E YT204001-FV |
| 20X4584-10A | YPM106E YT204001-FN |
| IS200AEBEG1AAB | YPR201A YT204001-KE |
| AAT141-S50 S2 | YXU167G YT204001-JE |
| HESG324063R100/G 216DB61 | YXU170E YT204001-JH |
| HESG448230R1/G 216EA61B | 330193-09-20-10-00 |
| PR6425/010-100 CON021 | HIEE320639R1 LT8978B V1 |
| EY-6691 SETX2 SUPPLY | MOX12-P3509B 80026-173-23-R |
cn@mooreplc.com +86 18030132586
Hot Tags: allen bradley 1756-oa8d controllogix digital i/o module, China allen bradley 1756-oa8d controllogix digital i/o module manufacturers, suppliers, 1771-P5, 1746 OA16 pdf, allen bradley, Allen Bradley 1746 OA16, 1746 OA16 manual, Allen Bradley 1746 OA16 Output Module PLC Module