Yokogawa EB401 ER Bus Interface Master Module

Yokogawa EB401 ER Bus Interface Master Module

YOKOGAWA · EB401 · ER BUS INTERFACE

Yokogawa EB401 ER Bus Interface Master Module

ER bus master communication module for connecting a local node or compact Field Control Unit with remote ER Bus Node Units.

Brand-new originalOne-year warrantySHIP FAST
SALES SUPPORT
Myrtle · Fast quotation and model check
Send Inquiry
Description

Product InformationProduct ImagesCompanyContactRecommended Models

YOKOGAWA CENTUM COMMUNICATION

Yokogawa EB401 ER Bus Interface Master Module

Yokogawa EB401 ER Bus Interface Master Module: IEEE 802.3 10BASE2 input, 4–20 mA output, eight input channels and eight output channels, non-isolated.

New & original
One-year warranty
SHIP FAST
Request a quote
PRODUCT OVERVIEW

Yokogawa EB401 at a glance

ER Bus Interface Master Module
Model
EB401
Product type
Analog I/O Module
Key rating
1–5 V DC or 4–20 mA
Primary use
The EB401 provides eight analog input channels and eight analog outpu

Description and purpose

Yokogawa EB401 ER Bus Interface Master Module: 1–5 V DC or 4–20 mA input, 4–20 mA output, eight input channels and eight output channels, non-isolated. Yokogawa lists EB401 as available for installation in an Local-to-remote node communication.

Technical specifications

EB401 configuration data · Yokogawa GS 33Q06Q48-31E

Model
EB401
Country of Origin
Japan
Official product name
ER Bus Interface Master Module
Function
ER bus interface function
Physical layer interface
IEEE 802.3 10BASE2 · 1 port
Connector
BNC
Communication speed
10 Mbps
Transmission distance
Maximum 185 m with YCB141 cable
Current consumption
0.7 A
Weight
0.3 kg
Installation 1
Compatible local node installation ANB10S or ANB10D
Installation 2
Compact Field Control Unit AFF50S, AFF50D, AFV10S or AFV10D
Redundancy
Two EB401 modules configure a dual-redundant ER bus
Single configuration
Install in an odd-numbered slot and leave the right-side slot empty
Supplied accessories
One YCB146 T-type connector and two YCB148 terminators
Suffix -5
Standard type without explosion protection
Suffix -E
Standard type with explosion protection
Suffix option 1
With ISA Standard G3 option
Official reference
Yokogawa GS 33Q06Q48-31E
CONFIGURATION SUPPORT

Trying to replace a difficult-to-source control module?

Send Myrtle the complete EB401 suffix code, node-unit model, ER bus arrangement and required quantity. We will check the requested configuration and supplied connector requirements before quoting.

Sales Manager · Myrtle
WHERE IT FITS

Application scenarios

FCU for FIO

The EB401 provides the ER bus master interface between an ESB Bus Node Unit or Compact Field Control Unit and remote ER Bus Node Units. It supports a single ER bus or a dual-redundant arrangement using two EB401 modules.

ESB Bus Node Unit

Installs in ANB10S or ANB10D ESB Bus Node Units, and in AFF50S, AFF50D, AFV10S or AFV10D Compact Field Control Units.

Dual-redundant ER bus

Two EB401 modules installed in the local node or compact FCS provide a dual-redundant ER bus configuration.

ER bus cable termination

Use the supplied YCB146 T-type connector and YCB148 terminators in accordance with the ER bus cable layout and Yokogawa documentation.

Ordering information

Payment
T/T
Port
Xiamen
Lead time
3–5 days
Condition
In stock
BUYER QUESTIONS

FAQ about Yokogawa EB401

Is Yokogawa EB401 the correct interface module for my node arrangement?

Confirm that the module is installed on the local side of an ER bus. EB401 is the master interface; remote ER Bus Node Units use the corresponding remote-side interface.

Which systems can accept a Yokogawa EB401?

Yokogawa specifies ANB10S and ANB10D ESB Bus Node Units plus AFF50S, AFF50D, AFV10S and AFV10D Compact Field Control Units.

What network interface does Yokogawa EB401 use?

The module uses one IEEE 802.3 10BASE2 physical-layer port with a BNC connector and communicates at 10 Mbps.

How far can a Yokogawa EB401 ER bus segment reach?

The official specification lists a maximum transmission distance of 185 m when YCB141 ER bus cable is used.

Can Yokogawa EB401 be configured redundantly?

Yes. Installing two EB401 modules in the local node or compact FCS configures a dual-redundant ER bus. For single configuration, use an odd-numbered slot and leave the slot on its right empty.

Which suffix and accessories should be checked before ordering EB401?

Verify -5 or -E, the fixed code 0 and the optional G3 code 1. EB401 is supplied with one YCB146 T-type connector and two YCB148 terminators.

ABOUT PLCEXPORT

Coordinated support from PLCEXPORT China

PLCEXPORT China assists maintenance and project teams with current and legacy PLC and DCS parts. For EB401 enquiries, our team coordinates model review, quotation details and shipment planning around the customer request.

Part-number review

The EB401 designation and available suffix or product-ID details are reviewed before quotation.

Supply coordination

Availability, commercial terms and destination information are coordinated together for a clear EB401 supply plan.

Label verification

Nameplate and installed-module photos can be shared to support EB401 identification and compatibility review.

Worldwide communication

Myrtle follows EB401 quotation questions, model checks and delivery communication through one contact point.

INSIDE PLCEXPORT CHINA

Our team, workplace and order preparation

PLCEXPORT China technical training and automation knowledge sharing
Technical knowledge sharing

Our team reviews control-system architecture and product details to support accurate model discussions.

PLCEXPORT China office and brand display
PLCEXPORT in China

A dedicated local team connects customer enquiries with international automation-parts supply.

PLCEXPORT automation parts service team
Experienced service team

Sales and support colleagues work together on identification, quotation and delivery coordination.

PLCEXPORT warehouse inspection and shipment preparation
Warehouse verification

Model labels and package details are reviewed as part of practical order and dispatch preparation.

Recommended Models

Siemens & Bently Nevada - published products

PLC & DCS REFERENCES

Others - other recommended brands

Keba
C5-IPC
Aaeon
BOXER-6641
Advantech
APAX-5580
Lütze
716425
Elmo
G-MAS
Festo
CPX-E-CEC
Gefran
GFX4-IR
Jetter
JC-440
Kontron
KBox-A-150
Lenze
c550
Nidec
C200-064
PMA
KS98-2
Sorel
XHCC
Toshiba
V200-16MR
Teco
SG2-20VR
Wieland
samosPRO
Yokogawa
FA-M3V
Zander
TALOS-TB
Crouzet
em4-remote
Hitachi
EH-150
Idec
FT1A-H40RSA
Koyo
DL06
Mitsubishi
FX5UC-32MT
Omron
NX1P2-9024DT
DIRECT SALES SUPPORT

Need a quick compatibility and supply check?

Industrial automation part numbers often include suffixes, connector options and system-specific details. Send the installed module information to Myrtle, and we will help organize the request before preparing a quotation.

What to send

Full model and suffix code, clear nameplate photos, required quantity, destination and requested delivery date.

What we can check

Available configuration, visible label details, cable or terminal requirements, commercial terms and shipping arrangements.

Sales Manager: Myrtle

↑ BACK UP TO THE TOP

Hot Tags: yokogawa eb401 er bus interface master module, China yokogawa eb401 er bus interface master module manufacturers, suppliers, yokogawa, yokogawa network interface card, YOKOGAWA V1701 VI702, YOKOGAWA VF701, YOKOGAWA VF701 Interface Card, YOKOGAWA VF702

Send Inquiry