SIEMENS 6ES7288-5BA01-0AA0 SB BA01 Battery Signal Board
The SB BA01 is a compact battery signal board for the SIMATIC S7-200 SMART platform. With a user-supplied CR1025 coin cell installed, it provides backup support for the CPU real-time clock and reports a low-battery condition through its red indicator and controller diagnostics.
|
CR1025
Cell purchased separately |
3 V / 30 mAh
Rated battery data |
< 2.5 V
Low-voltage threshold |
35 × 52.2 × 16 mm
Compact signal-board size |
Technical Specifications
|
CLOCK-BACKUP PLANNING
Replacing a missing clock-backup board?Send Myrtle the full CPU number and tell us whether the existing BA01 is missing, damaged or reporting a low battery. We can help separate a board requirement from a simple CR1025 replacement before quotation. WhatsApp +86-18950128464Email sales5@askplc.com |
![]() |
Where the SB BA01 earns its place
Machines with time-stamped eventsUseful where a compatible S7-200 SMART CPU must retain real-time-clock continuity for alarms, batches or maintenance records after control power is removed. |
Seasonal and intermittently powered equipmentSuitable for panels that may remain de-energized between production campaigns yet still require sensible date and time information at restart. |
Compact OEM control cabinetsThe signal-board format adds clock backup without occupying the footprint of a full expansion module, a practical fit for packaging, assembly and small process skids. |
Replacement and maintenance stockA useful spare for sites operating S7-200 SMART CPUs equipped for the BA01, especially when low-battery diagnostics or damaged board hardware calls for planned service. |
FAQ
|
Q1
Is a CR1025 battery supplied with 6ES7288-5BA01-0AA0?No. Siemens identifies the SB BA01 as the battery board only; the CR1025 coin cell must be purchased separately. |
Q2
What does the SB BA01 preserve when the controller loses power?Its role is to provide battery backup for the real-time clock function of a compatible S7-200 SMART CPU. It is not an I/O expansion board. |
|
Q3
How should the CR1025 cell be installed?Install the new cell with the positive side facing upward and the negative side toward the printed circuit board, following the Siemens installation procedure. |
Q4
How is a weak battery reported?When battery voltage falls below the critical level, the BA01 red LED remains on and the controller can issue a low-battery diagnostic indication. |
|
Q5
How long can the battery provide retention?Siemens lists an approximate retention period of one year. Actual service life can vary with storage, temperature and the condition of the selected cell. |
Q6
What information should be checked before ordering a replacement?Confirm the complete article number, CPU family, existing signal-board position and whether a fresh CR1025 cell is also required. |
Recommended PLC & DCS Models
ABB
|
3BHE014967R0001 UNS2880B-P
Control Module
|
QPWR-562 3AXD50000019575
Circuit Board
|
|
CM588-CN-XC 1SAP372800R0001
Communication Module
|
1MRK001987-AA
Binary Input Module
|
|
TC625 3BSE002224R1
Coaxial Modem
|
HIEE205010R0003 UNS3020A-Z,V3
PLC Module
|
|
NDNA-02 NDNA-02-KIT
DeviceNet Adaptor
|
07KP64 GJR5240600R0101
Communication Processor
|
|
DTPC721B 3EST126-236
Power Control Unit
|
CI560 3BUC980002R1
TRIO Interface Submodule
|
HIMA
|
F1101
Switching Amplifier
|
F4204
Process Module
|
|
F7105A
Process Module
|
F3322
16-fold Digital Output Module
|
|
F7126
Power Supply Module
|
F3421
Digital Output Module
|
|
H4135A
Safety-Related Relay
|
F8620
Central Processing Unit
|
|
F3349
Digital Output Module
|
F6205
Relay Control Module
|
Others
|
Mitsubishi QJ71E71-100
Ethernet Interface Module
|
Omron CJ1W-ID211
Digital Input Unit
|
|
Beckhoff EL1809
Digital Input Terminal
|
WAGO 750-430
Digital Input Module
|
|
Bachmann DI232
Digital Input Module
|
Hitachi EH-CPU208A
PLC CPU Module
|
|
Toshiba PU11
Process Control CPU
|
Fuji NP1PS-74R
PLC Power Supply
|
|
Saia PCD3.M5540
Automation Controller
|
Bosch Rexroth R-IL DI 16/HD
Digital Input Module
|
|
ABOUT PLCEXPORT
Careful sourcing starts with the small detailsA battery board may be compact, but selecting it still depends on the controller family, complete order number and maintenance objective. PLCEXPORT helps customers check those details before a quotation is prepared. Our team supplies PLC, DCS and safety-system components to maintenance teams and machine builders worldwide, with support for current, discontinued and difficult-to-source parts. |
![]() |
|
CONTACT & INQUIRY
Tell us what must still be correct after the power returnsSend the complete CPU and board numbers, required quantity and delivery country. If the problem is only a depleted CR1025 rather than the BA01 board itself, include the diagnostic symptoms so Myrtle can review the request more accurately.
|
![]() |
Hot Tags: siemens 6es7288-5ba01-0aa0 simatic s7-200 smart sb ba01 battery signal board, China siemens 6es7288-5ba01-0aa0 simatic s7-200 smart sb ba01 battery signal board manufacturers, suppliers, 6ES7 315 2AH14 0AB0, 6ES7 315 2AH14 0AB0 Siemens, 6ES7317 2EK14 0AB0 Central processing unit, 6ES7317 2EK14 0AB0 Siemens, siemens, Siemens 6ES7317 2EK14 0AB0