Products Description
The Siemens RMS-TSG-TZ-C is a static trip unit designed for low-voltage power distribution systems, enhancing the protection capabilities of air circuit breakers. This module accurately monitors and rapidly disconnects overloads, short circuits, and ground faults, ensuring the safe operation of power systems.
Technical parameters
|
Part number |
RMS-TSG-TZ-C |
|
Product Type |
Circuit Breaker |
|
Rated Current |
Up to 6300A |
|
Rated Voltage |
Up to 16kV |
|
Temperature Rating |
-25°C to +60°C |
|
Relay Accuracy |
≤ 0.5% |
|
Control Power Supply |
DC 24V ± 10% |
Contact us
|
Sales: |
Email: |
Whatsapp: |
|
Winnie |
Key Features
Product Type: Static Trip Unit, Non-Independent Circuit Breaker
Series: Siemens Static Trip III Trip Module Series
Function: Overload, short circuit, and ground fault protection
Applicable Equipment: Compatible with Siemens low-voltage air circuit breakers RL, RLE, and RLI series
Adjustable Parameters: Supports long-delay, short-delay, instantaneous, and ground fault protection settings
Industrial Design: Rugged and durable, suitable for high-load power systems
Application Scenarios
Industrial low-voltage switchgear
Building power systems
Power supply protection for large machinery and equipment
Power system safety monitoring and fault disconnection
FAQ
Q: What type of product is RMS-TSG-TZ-C?
A: This is a Static Trip III Trip Unit, a protection module for low-voltage power distribution systems. It provides overload, short-circuit, and ground fault protection for air circuit breakers. It is not a standalone circuit breaker and needs to be used in conjunction with a low-voltage circuit breaker body.
Q: Which circuit breaker series is it compatible with?
A: This module is commonly used with Siemens RL, RLE, RLI, and RLF series low-voltage air circuit breakers to enhance the circuit breaker's protection functions and achieve flexible protection settings.
Q: How reliable is the module?
A: The product design conforms to industry standards and can operate stably under high loads and complex environments, ensuring that the circuit breaker quickly disconnects the circuit in the event of a fault, preventing equipment damage or safety accidents.
Q: Can the protection settings be adjusted?
A: Yes, users can set long-delay, short-delay, instantaneous, and ground fault protection parameters according to system load and application requirements to meet the power protection requirements in different scenarios.
Hot Recommendations
|
PRO4-101.7098QS |
VM60/EB-TA |
C-551S |
|
SM-64-1-0 / SM6410 |
131B0518 |
THYPO-P |
|
XN-4AI-U/I |
3RT2036-1AN60 |
H1P-D64 |
|
CS1W-BC083 |
CQM1-IA221 |
CS62US |
|
CS1W-BC083 |
5SL6006-6 |
EL6910-0000 |
|
FDS2014/B |
A68DAI-S1 |
QX80 |
|
DS201 C16 A30 |
3RS2900-2AW30 |
CP1H-XA40DR-A |
|
AS-H819-103 |
C500-OD217 |
RLP100 F003 |
|
4AV2302-2EB00-0A |
FX-32MT-ESS |
VFD075F43B |
|
175U0043 |
ELR H3-IES-SC- 24DC/500AC-9 |
CS1W-BI103 |
|
CS1W-EIP21 |
195N0003 |
CS1W-BI103 |
|
CS1W-EIP21 |
CJ1W-PRM21 |
CP1L-M30DT-D |
|
PE1843/02 |
510-500/130 |
E3S-R11 |
|
CQM1H-PLB21 |
DS2400N-1200 |
MK5101 |
|
A1SJ71QE71-B5 |
3G3EV-A2001M |
CS1W-ETN11 |
Hot Tags: siemens rms-tsg-tz-c circuit breaker, China siemens rms-tsg-tz-c circuit breaker manufacturers, suppliers