Products Description
The T8270 Fan Assembly Module is a rack-mounted cooling component used in industrial safety control systems. It is engineered to provide continuous forced airflow inside the module rack, helping maintain stable operating temperatures for control processors and I/O modules.
The assembly consists of multiple axial fans installed within a 2U rack chassis positioned at the rear of the control cabinet. By drawing air through the rack and exhausting it toward the cabinet ventilation path, the module helps prevent overheating and ensures reliable long-term operation of critical automation electronics.
Functional Role / System Position
Within the Trusted control platform, the T8270 operates as a thermal management device installed inside the module rack. Its main role is to generate consistent airflow across control modules, allowing heat produced by processors, power supplies, and interface cards to dissipate efficiently.
The fan assembly receives its power from the system's 24 VDC distribution supply and typically works alongside cabinet ventilation systems such as roof-mounted fans. This coordinated airflow design ensures stable cooling performance across the entire control cabinet.
Key Features / Functional Capabilities
- Rack-mounted fan tray design supporting efficient cabinet cooling
- Multiple industrial fans delivering continuous airflow across control modules
- 24 VDC operating architecture compatible with industrial control power systems
- Integrated airflow management structure preventing recirculation inside the rack
- Low-noise operation suitable for control room or cabinet installations
- Reliable cooling performance ensuring stable operation of safety and automation modules
Application Areas / Typical Use Cases
- Safety instrumented systems used in process industries
- Distributed control systems within petrochemical plants
- Power generation turbine control cabinets
- Industrial automation racks requiring forced airflow cooling
- Replacement cooling units for Trusted control system installations
Technical Specifications
| Parameter | Specification |
|---|---|
| Product Model | T8270 |
| Manufacturer | ICS Triplex |
| Module Type | Rack-Mounted Fan Assembly |
| Operating Voltage | 18–28 VDC |
| Fan Configuration | 4 × Papst 8414NG industrial fans |
| Airflow (per fan) | Approx. 69 m³/h |
| Power Consumption | 2 × 4 W |
| Noise Level | Approx. 32 dB per fan |
| Operating Temperature | 0 °C to +60 °C |
| Storage Temperature | -20 °C to +70 °C |
| Dimensions (H × W × D) | 88 mm × 483 mm × 267 mm |
| Weight | Approx. 1.8 kg |
Contact Information
For pricing, availability, or technical consultation regarding this model, please contact our sales team:
【Sales Manager】
Silver
【WhatsApp】
+86-18020714492

【Email】
sales1@askplc.com
【WeChat】
+86-18020714492
FAQ
Q1: What is the main function of the T8270 module?
It provides forced airflow inside a control rack to maintain safe operating temperatures for industrial automation modules.
Q2: How many fans are installed in the T8270 assembly?
The module typically contains four industrial cooling fans arranged vertically inside the rack chassis.
Q3: What voltage does the fan assembly require?
The system operates using 24 VDC power, typically within an 18–28 VDC input range.
Q4: Where is the module installed within the control system?
It is mounted in the rear section of a module rack to draw air through system electronics and exhaust warm air out of the cabinet.
Q5: Why is proper cooling important in control cabinets?
Adequate airflow prevents overheating of processors and I/O modules, which helps maintain system stability and extend component service life.
Welcome to Inquiry Below
| VIBRO METER | VM600 IOCN 200-566-000-113 | Allen-Bradley | 1336-BDB-SP30D |
| VIBRO METER | VM600 IOC4T 200-560-000-111 | Allen-Bradley | 1336-BDB-SP29D 74101-169-53 |
| VIBRO METER | VM600 CPUM 200-595-100-032 | Allen-Bradley | 1336-BDB-SP29C 74101-169-53 |
| VIBRO METER | VM600 CPUM 200-595-100-014 | Allen-Bradley | 1336-BDB-SP29A 74101-169-53 |
| VIBRO METER | VM600 CPU-M 200-595-064-114 | Allen-Bradley | 1336-BDB-SP17C 74101-482-51 |
| VIBRO METER | VM600 CPU M 209-595-200-232 | Allen-Bradley | 1336-B005-EAD-FA2-L1-S1 |
| VIBRO METER | VM600 CPU M 209-595-200-132 | Allen-Bradley | 1326AB-B720E-S2L |
| VIBRO METER | VM600 CPU M 200-595-045-114 | Allen-Bradley | 1326AB-B515E-S2K5L |
| VIBRO METER | VM600 CPU M 200-595-041-113 | Allen-Bradley | 1326AB-B430E-21 |
| VIBRO METER | UVV694 204-694-000-023S | Allen-Bradley | 1305-KBA09 |
... ... ...(MORE)
Hot Tags: ics triplex t8270 fan assembly module, China ics triplex t8270 fan assembly module manufacturers, suppliers