Products Description

FS-TSFIRE-1624 provides the field connection point between 24 V fire detectors and the SAI-1620m module in Honeywell Safety Manager. Sixteen digital detector channels support both safety-related and non-safety-related applications, giving the module a practical role in fire detection system integration.
Technical Specifications For FS-TSFIRE-1624
| Parameter | Specification |
| Brand |
HONEYWELL |
| Model |
FS-TSFIRE-1624 |
| Product Type | Safe fire detector input Field Termination Assembly (FTA) |
| System |
Honeywell Safety Manager |
| Input Channels |
16 digital detector input channels |
| Application Type |
Safety-related and non-safety-related applications |
| Hazardous Area Capability |
Suitable for installations and signal interfacing in Class I, Division 2 Hazardous Locations |
| Field Wire Resistance |
Less than 100 Ohm |
| Global Reset |
Relay-controlled reset of connected detectors by removing field supply voltage |
| Global Reset Safety Classification |
Non-safety-related |
| Field Wiring Termination |
Screw terminals |
| Maximum Wire Diameter |
2.5 mm² (AWG 14) |
| Number of Screw Terminals |
48 |
| Terminal Tightening Torque |
0.5 Nm (0.37 ft-lb) |
Require for Quote

Looking for hard-to-find automation parts?
Send us your part number today and receive a fast, competitive quotation from our experienced team.
- Website:Https://www.plcexport.com/
- Sales Manager: Myrtle
-💬 Email: sales5@askplc.com
- 📱Phone (WhatsApp):+86-18950128464
FAQ FOR the FS-TSFIRE-1624
Q: What type of field devices can FS-TSFIRE-1624 connect to?
A: FS-TSFIRE-1624 is designed to interface 24 V fire detectors and can also be used with manual call points. The detector signals are converted to levels suitable for the SAI-1620m module in Safety Manager.
Q: What happens when a global reset is activated on FS-TSFIRE-1624?
A: The relay in FS-TSFIRE-1624 removes the field supply voltage from the connected detectors, allowing the detectors to reset. The global reset function is classified as non-safety-related.
Q: How does FS-TSFIRE-1624 connect to the Safety Manager system?
A: FS-TSFIRE-1624 uses an SICC-0001/Lx system interconnection cable to transfer the 16 input signals to a redundant pair of SAI-1620m modules. Field devices and the external power supply are connected through screw terminals.
KEY FEATURE
16-channel fire detector interface with dedicated signal conditioning for connection to the SAI-1620m within Honeywell Safety Manager.
24 V DC detector supply with voltage and current limitation, supporting Class I, Division 2 hazardous-area installations.
Integrated global reset relay allows connected fire detectors to be reset by removing field supply voltage
RECOMMENDED PARTS ABOUT HONEYWELL
|
51304540-200 |
FC-TSHART-1620M |
05704-A-0145 |
FC-TSAO-0220M |
|
8C-PAON01 51454357-175 |
51403776-100 |
FC-TSDI-1624 |
FC-IOCHAS-0001S |
|
51195096-200 |
51402497-200 |
FTA-T-15 |
FC-TERM-0002 |
|
51304159-100 |
K4LCN-16 51403519-160 |
FTA-T-21 |
LHC252015 |
|
51304584-100 |
51303979-550 |
SB3610-B |
CC-PCNT01 51405046-175 |
|
51305072-700 |
51304518-150 |
51401635-150 |
8C-TAIXA1 51307127-175 |
|
51306803-100 |
51402615-400 |
51202330-200 |
SPS5710 51199929-100 |
|
900B01-0101 |
10020/1/2 |
CC-TAON01 51306519-175 |
8C-PAIN01 51454356-175 |
|
900G02-0102 |
05701-A-0301 |
TK-PPD011 51309241-175 |
CC-PDIL01 51405040-175 |
|
900H03-0102 |
51402573-250 |
TK-RPCXX1 |
10001/A/1 |
|
R02S02L03 |
51304831-100 |
CC-PFB401 51405044-175 |
10005/1/1 |
|
TC-HAO081 |
80363972-150 |
05701-A-0325 |
10024/H/F |
|
TC-IDA161 |
MC-IOLX02 51304419-150 |
51402573-150 |
10105/2/1 |
|
MC-PRHM01 51404109-175 |
MC-PAIH03 51304754-150 |
51195153-902 |
10216/2/1 |
|
38500143-200 |
51309218-175 MC-TAMR03 |
51195199-010 |
8C-PDIL51 51454359-175 |
|
8C-TDOD51 |
8C-PAIMA1 51454473-175 |
51196041-100 |
CC-PAON01 51410070-175 |
Hot tags:FS-TSFIRE-1624;FS-TSFIRE-1624 new;FS-TSFIRE-1624 PDF;FS-TSFIRE-1624 manual;FS-TSFIRE-1624 sell;FS-TSFIRE-1624 date sheet;
Hot Tags: honeywell fs-tsfire-1624 integrated detector reset, China honeywell fs-tsfire-1624 integrated detector reset manufacturers, suppliers