Products Description
HONEYWELL TK-OAV061 Analog Output Module
The HONEYWELL TK-OAV061 Analog Output Module is a precision interface module designed for excitation and field control systems, delivering accurate analog output signals to downstream regulators, sensors, and excitation devices. Unlike general I/O modules, it is optimized for excitation system architectures, ensuring minimal signal distortion, high reliability, and seamless integration with redundant or dual-node setups.
This module enables controlled analog signal transmission for voltage, current, or feedback loops within an excitation network, providing stable performance under fluctuating electrical or thermal conditions.
With over 50 million in inventory, PLC EXPORT delivers only brand-new, authentic components- ready to ship,
rigorously tested, and backed by professional technical support.
Our address
32D Guomao Building, Siming District, Xiamen, Fujian, China
Phone Number(Whatsapp)
+86-18020714492
sales1@askplc.com

Functional Role / System Position
Within an excitation system, the TK-OAV061 functions as a signal conditioning and output interface, converting digital control commands into precise analog signals that regulate excitation hardware. It sits between the excitation controller and field devices, ensuring that target field currents, voltages, or other controlled parameters are accurately maintained.
Its placement is critical in systems requiring real-time response and high-fidelity analog communication between control electronics and the excitation hardware.
Key Features / Functional Capabilities
- High-precision analog output for excitation control circuits
- Compatible with dual-node or redundant excitation architectures
- Supports voltage and current output modes
- Electrically isolated channels to protect system controllers
- Low-noise design suitable for industrial environments
- Fast response time to enable real-time field adjustments
Application Areas / Typical Use Cases
- Generator excitation control loops
- Industrial synchronous motor field regulation
- Turbine-generator feedback and analog control systems
- Redundant excitation signal distribution networks
- Retrofitting existing excitation systems with analog output capability
Product Identification
| Parameter | Specification |
|---|---|
| Module Type | Analog Output Module |
| Manufacturer | Honeywell |
| Model | TK-OAV061 |
| Signal Type | Voltage / Current Output |
| Output Range | 0–10 V / 4–20 mA (configurable) |
| Channel Count | 4 isolated analog outputs |
| Accuracy | ±0.1% of full scale |
| Response Time | ≤ 2 ms per channel |
| Electrical Isolation | ≥ 1500 Vrms per channel |
| Supply Voltage | 24 VDC nominal |
| Power Consumption | ≤ 5 W |
| Operating Temperature | 0–60°C |
| Storage Temperature | -40–85°C |
| Mounting | DIN rail or panel mount |
| Environmental Rating | Industrial control environment |
Installation / Handling
The TK-OAV061 should be installed in a control panel or excitation cabinet with proper grounding. Connections to excitation controllers and field devices must respect the specified isolation requirements to prevent signal interference. Modules can be hot-swapped only if system design allows; otherwise, power down the excitation cabinet before maintenance.
Advantages / Value Highlights
- Provides precise and stable analog outputs for field excitation systems
- Protects controllers via electrically isolated outputs
- Compatible with both modern and legacy excitation architectures
- Reduces maintenance impact through modular, easy replacement design
- Enhances reliability of feedback-controlled excitation loops
Supply & Warranty Information
The HONEYWELL TK-OAV061 Analog Output Module is supplied as a standalone module with standard industrial packaging. Warranty terms align with Honeywell industrial I/O standards and cover manufacturing defects when used under specified operating conditions.
MORE OPTIONS
| WESTINGHOUSE | 5X00273G01 | Schneider | 171CCS78000 |
| WESTINGHOUSE | 5X00226G01 | Schneider | 416NHM30030A |
| WESTINGHOUSE | 5X00121G01 | Schneider | 490NRP25400 |
| WESTINGHOUSE | 5X00119G01 | Schneider | 990XCP98000 |
| WESTINGHOUSE | 5X00109G02 | Schneider | AM-SA85-000 |
| WESTINGHOUSE | 5X00109G01 | Schneider | AS-P890-000 |
| WESTINGHOUSE | 5X00106G01 | Schneider | AS-S908-110 |
| WESTINGHOUSE | 5X00105G14 | Schneider | ATV61HD37N4 |
| WESTINGHOUSE | 5X00070G04 | Schneider | BCH2MM0813CA6C IEC 60034-1 |
Common problems
Q1: Can the module handle both voltage and current outputs simultaneously?
Yes, each output channel can be configured individually for voltage or current mode.
Q2: Is the module compatible with dual-node excitation systems?
Yes, it is designed to integrate into redundant or dual-node excitation architectures.
Q3: What is the maximum output accuracy?
±0.1% of full scale ensures precise excitation control.
Q4: Can the module operate in high-noise industrial environments?
Yes, channels are electrically isolated and designed for industrial-level noise immunity.
Q5: How is the module mounted?
It can be installed on a DIN rail or in a control panel with standard mounting brackets.
Hot Tags: honeywell tk-oav061 analog output module, China honeywell tk-oav061 analog output module manufacturers, suppliers, CC PAIH01 51405038 175 Honeywell, Honeywell CC PCNT01 51405046 175, CC TAOX01 51308351 175 Honeywell, CC-PAIH01, Honeywell CC TAOX01 51308351 175, CC PAIH01 51405038 175