
Product Overview
UR8NH serves as an eight-channel current measurement module within the Multilin Universal Relay architecture, giving protection systems a dedicated interface for CT signals used in power-system monitoring and protection. The enhanced diagnostic architecture adds an important layer of measurement integrity by supervising analog channels, CT secondary circuitry and module supply voltage rather than relying only on the measured electrical values. UR8NH therefore fits applications where dependable current measurement is important for feeder, generator, motor, transformer and other electrical protection schemes using the compatible UR platform.
Technical Specifications For UR8NH
| Item | Specification |
| Manufacturer | General Electric |
| Model |
UR8NH |
| Product Family | Multilin Universal Relay |
| Product Type |
CT/VT DSP Module |
| CT/VT Option | 8N |
| CT Configuration |
Standard 8CT |
| Diagnostic Function |
Enhanced diagnostics |
| Analog Channel Arrangement | Eight CT channels |
Looking for hard-to-find automation parts?
Send us your part number today and receive a fast, competitive quotation from our experienced team.
Sales Manager:
Myrtle
💬Email: sales5@askplc.com
📱Phone (WhatsApp):+86-18950128464

20+ Years
Experience
Fast Worldwide
Delivery
Pricing
Competitive
KEY FEATURE
Standard 8CT Measurement
UR8NH provides the UR relay platform with a standard eight-current-transformer configuration. The eight-channel arrangement supports phase and ground-current measurement according to the applicable UR wiring configuration.
Enhanced Measurement Diagnostics
UR8NH uses analog data integrity checking to identify abnormal measurement-channel behavior. Persistent diagnostic errors can generate a major self-test condition, operate the self-test alarm contact and take the relay out of service rather than allowing questionable measurements to continue driving protection functions.
CT Hardware Integrity Monitoring
UR8NH supports internal CT secondary monitoring. The diagnostic architecture compares the two portions of the CT secondary circuit and can declare a failure when the measured discrepancy exceeds the applicable error boundary, allowing associated protection functions to be blocked.
FAQ
01.What function does UR8NH provide in a Multilin Universal Relay?
02.Why would a protection system use UR8NH instead of a basic CT input module?
03.How many current inputs can UR8NH provide?
04.Can UR8NH accept both 1 A and 5 A CT secondary ratings?
05.How does UR8NH detect an analog measurement problem?
06.What happens when UR8NH detects persistent invalid analog data?

About PLCEXPORT
PLC Export has over 20 years of experience supplying industrial automation spare parts worldwide.With a large inventory, strong sourcing network, and extensive industry experience, we help customers find obsolete and urgent replacement parts faster. Competitive pricing, careful packaging, reliable global shipping, and efficient order handling make PLC Export a trusted choice for automation spare parts worldwide.
Recommended Part About Other Brands
|
HIMA |
FOXBORO |
EMERSON |
GE |
|
K9203 |
RLY4 2500M/RLY4 |
PR6423/10R-010 CON021 |
IS210BPPCH1AEC |
|
F3236 |
P0916DB |
KJ3202X1-BA1 12P2536X042 VE4032S1T2B1 |
IS210AEAAH3BKE |
|
F7126 |
P0914XB |
PR6424/000-040 CON021 |
DS200PTBAG1BBA |
|
F3322 |
FBM218 P0922VW |
VE4037P0 KJ3242X1-BA1 12P2471X052 |
IS220PPRFH1B |
|
F7105A |
P0916NG |
KJ3102X1-BB1 12P1864X032 |
8709-CA-08 |
|
F2201 |
P0400YD FBM3 |
A6312/06 |
269PLUS-D/O-100P-125VDC |
|
F3417A |
FBM205 P0914XG |
KJ3202X1-BA1 12P2536X062 VE4032S1T2B1 |
IC693BEM331 |
|
F4204 |
P0916WF |
FX-340 |
EPSCPE100-ABAA |
|
F1101 |
FBM215 |
KJ3222X1-BA1 12P2532X072 |
IS210BPPBH2BLD |
|
F3113A |
FBM223 P0917HD |
KJ3008X1-BA1 12P2293X052 |
IS220PIOAH1A |
|
F3423 |
P0916AA |
KJ2221X1-BA1 12P3232X132 VS6002 |
TGT-3X6L-1-0-BD |
|
F7130 |
B0123HE |
KJ3201X1-BA1 12P2535X042 VE4001S2T2B2 |
750-P5-G5-S5-HI-A20-R-E |
|
HIMATRIX F3DIO8/801 F3 DIO 8/8 01 |
FBM1/37/43 P0400HH |
KJ3222X1-BA1 12P2532X092 |
IS200ECTBG1ABB |
|
HIMATRIX F2DO1602 F2 DO 16 02 |
AD916AE |
KJ3002X1-BG2 12P1731X062 |
UR6BH |
|
HIMATRIX F60GEH01 F60 GEH 01 |
P0917MF |
KJ3001X1-BG1 12P0557X162 |
UR 9EH UR9EH |
|
H7506 |
FCP280 RH924YA |
R6423/010-010 CON021 |
IC693PBS105 |
|
Z7116 |
FBM228 P0922QS |
KJ3002X1-BB1 12P0683X092 VE3006 |
6231BP10820 IC660EBA024 |
|
Z7126 |
FBM231 |
KJ4001X1-CA1 12P0623X072 |
IC697MDL240 |
|
Z7128 |
FBM3A/33A P0500RU |
PR6424/006-131 CON041 |
IS220PDIAH1A |
Hot tags:UR8NH;UR8NH new;UR8NH PDF;UR8NH manual;UR8NH sell;UR8NH date sheet;
Hot Tags: general electric ur8nh enhanced diagnostic ct module, China general electric ur8nh enhanced diagnostic ct module manufacturers, suppliers

