General Electric UR8NH Enhanced Diagnostic CT Module

General Electric UR8NH Enhanced Diagnostic CT Module

Part Number: UR8NH
Brand: General Electric
Warranty: 12months
Condition: Brand new& in Stock
Origin: USA
delivery time: 3-5 days
Sales Manager: Myrtle
Email: sales5@askplc.com
Phone: +86-18950128464
Send Inquiry
Description
UR8NH new
Product Overview

UR8NH serves as an eight-channel current measurement module within the Multilin Universal Relay architecture, giving protection systems a dedicated interface for CT signals used in power-system monitoring and protection. The enhanced diagnostic architecture adds an important layer of measurement integrity by supervising analog channels, CT secondary circuitry and module supply voltage rather than relying only on the measured electrical values. UR8NH therefore fits applications where dependable current measurement is important for feeder, generator, motor, transformer and other electrical protection schemes using the compatible UR platform.

1

Technical Specifications For UR8NH

Item Specification
Manufacturer General Electric
Model

UR8NH

Product Family Multilin Universal Relay
Product Type

CT/VT DSP Module

CT/VT Option 8N
CT Configuration

Standard 8CT

Diagnostic Function

Enhanced diagnostics

Analog Channel Arrangement Eight CT channels
Require for Quote

Looking for hard-to-find automation parts?

Send us your part number today and receive a fast, competitive quotation from our experienced team.

Sales Manager:

 Myrtle

💬Email: sales5@askplc.com

📱Phone (WhatsApp):+86-18950128464

4

20+ Years

Experience

Fast Worldwide

Delivery

Pricing

Competitive

 

 

KEY FEATURE

 

Standard 8CT Measurement

UR8NH provides the UR relay platform with a standard eight-current-transformer configuration. The eight-channel arrangement supports phase and ground-current measurement according to the applicable UR wiring configuration.

Enhanced Measurement Diagnostics

UR8NH uses analog data integrity checking to identify abnormal measurement-channel behavior. Persistent diagnostic errors can generate a major self-test condition, operate the self-test alarm contact and take the relay out of service rather than allowing questionable measurements to continue driving protection functions.

CT Hardware Integrity Monitoring

UR8NH supports internal CT secondary monitoring. The diagnostic architecture compares the two portions of the CT secondary circuit and can declare a failure when the measured discrepancy exceeds the applicable error boundary, allowing associated protection functions to be blocked.

FAQ

 

 

01.What function does UR8NH provide in a Multilin Universal Relay?

UR8NH provides a standard eight-CT input configuration for the Multilin Universal Relay platform. The 8N option is identified as Standard 8CT with enhanced diagnostics.

02.Why would a protection system use UR8NH instead of a basic CT input module?

UR8NH adds enhanced diagnostic functions to the eight-CT measurement arrangement. Analog data integrity checking, CT secondary monitoring and power-supply rail supervision help identify internal measurement problems before unreliable analog information can continue influencing protection functions.

03.How many current inputs can UR8NH provide?

UR8NH is specified as a standard 8CT module, providing eight CT channels. The channel arrangement covers two four-channel banks.

04.Can UR8NH accept both 1 A and 5 A CT secondary ratings?

Yes. UR installation documentation specifies CT secondary ratings of 1 A or 5 A. The connected CT secondary rating must match the nominal current configuration of the relay terminals.

05.How does UR8NH detect an analog measurement problem?

UR8NH uses an additional analog hardware channel and an analog data integrity calculation. The measured channel values are compared with a digitally calculated result, and excessive discrepancy can cause invalid data to be declared.

06.What happens when UR8NH detects persistent invalid analog data?

Persistent diagnostic errors can produce a major self-test diagnostic message, operate the relay self-test alarm contact and take the relay out of service. Protection functions associated with invalid measured data can also be blocked.

 

AB ABB BENTLY NEVADA

About PLCEXPORT

 

PLC Export has over 20 years of experience supplying industrial automation spare parts worldwide.With a large inventory, strong sourcing network, and extensive industry experience, we help customers find obsolete and urgent replacement parts faster. Competitive pricing, careful packaging, reliable global shipping, and efficient order handling make PLC Export a trusted choice for automation spare parts worldwide.

 

2

Recommended Part About Other Brands

 

HIMA

FOXBORO

EMERSON

GE

K9203

RLY4 2500M/RLY4

PR6423/10R-010 CON021

IS210BPPCH1AEC

F3236

P0916DB

KJ3202X1-BA1 12P2536X042 VE4032S1T2B1

IS210AEAAH3BKE

F7126

P0914XB

PR6424/000-040 CON021

DS200PTBAG1BBA

F3322

FBM218 P0922VW

VE4037P0 KJ3242X1-BA1 12P2471X052

IS220PPRFH1B

F7105A

P0916NG

KJ3102X1-BB1 12P1864X032

8709-CA-08

F2201

P0400YD FBM3

A6312/06

269PLUS-D/O-100P-125VDC

F3417A

FBM205 P0914XG

KJ3202X1-BA1 12P2536X062 VE4032S1T2B1

IC693BEM331

F4204

P0916WF

FX-340

EPSCPE100-ABAA

F1101

FBM215

KJ3222X1-BA1 12P2532X072

IS210BPPBH2BLD

F3113A

FBM223 P0917HD

KJ3008X1-BA1 12P2293X052

IS220PIOAH1A

F3423

P0916AA

KJ2221X1-BA1 12P3232X132 VS6002

TGT-3X6L-1-0-BD

F7130

B0123HE

KJ3201X1-BA1 12P2535X042 VE4001S2T2B2

750-P5-G5-S5-HI-A20-R-E

HIMATRIX F3DIO8/801 F3 DIO 8/8 01

FBM1/37/43 P0400HH

KJ3222X1-BA1 12P2532X092

IS200ECTBG1ABB

HIMATRIX F2DO1602 F2 DO 16 02

AD916AE

KJ3002X1-BG2 12P1731X062

UR6BH

HIMATRIX F60GEH01 F60 GEH 01

P0917MF

KJ3001X1-BG1 12P0557X162

UR 9EH UR9EH

H7506

FCP280 RH924YA

R6423/010-010 CON021

IC693PBS105

Z7116

FBM228 P0922QS

KJ3002X1-BB1 12P0683X092 VE3006

6231BP10820 IC660EBA024

Z7126

FBM231

KJ4001X1-CA1 12P0623X072

IC697MDL240

Z7128

FBM3A/33A P0500RU

PR6424/006-131 CON041

IS220PDIAH1A

 Hot tags:UR8NH;UR8NH new;UR8NH PDF;UR8NH manual;UR8NH sell;UR8NH date sheet;

Hot Tags: general electric ur8nh enhanced diagnostic ct module, China general electric ur8nh enhanced diagnostic ct module manufacturers, suppliers

Send Inquiry