Products Description
The Bently Nevada 990-04-50-02-00 990 Vibration Transmitter is designed for OEM applications where reliable vibration monitoring must be integrated directly into a plant control or protection system. It is commonly used on centrifugal air compressors, small pumps, motors, and fans that require a straightforward vibration signal without the complexity of a full monitoring rack.
This transmitter is a two-wire, loop-powered device that interfaces with a 3300 NSv proximity probe and its matching extension cable, available in 5 m or 7 m system lengths. The 990 transmitter conditions the raw probe signal into accurate peak-to-peak vibration amplitude engineering units, then converts the measurement into a standard 4–20 mA output.
By delivering a proportional current signal directly to PLCs, DCSs, or other control systems, the 990-04-50-02-00 allows vibration-based alarming and protective logic to be handled externally. This makes it a cost-effective, compact, and robust solution for continuous vibration monitoring in OEM machinery designs.

Contact Us to Get the Best Price
| Sales Person | Felicia |
| Whatsapp/Wechat | +86 18030132586 |
| cn@mooreplc.com | |
| Phone Number | +86 18030132586 |
Products Parameters
| Category | Item | Specification |
|---|---|---|
| Input | Probe type | One non-contacting 3300 NSv proximity probe with extension cable |
| Power Supply | Input at transmitter terminals | +12 to +35 V DC |
| Signal Output | Output range | 4–20 mA DC over specified full-scale range, 2-wire loop-powered |
| Loop Accuracy | Error band | Within ±1.5 % of full-scale (TEST input, 250 Ω loop resistance); accuracy excludes Prox Out incremental scale factor |
| Probe Gap | Target distance | 0.5 – 1.75 mm (20 – 55 mils) from target at full-scale |
| Current Limiting | Limit value | 23 mA typical |
| Zero / Span | Adjustment method | Non-interacting external zero and span adjustments |
| NOT OK / Signal Defeat | Output behavior | Output drops below 3.6 mA within 100 µs after NOT OK; recovers within 2–3 s after NOT OK is cleared |
| Maximum Loop Resistance | Including cable | Up to 1,000 Ω at 35 V DC |
| Temperature Stability | Incremental scale factor | Within ±10 % of 7.87 mV/µm (200 mV/mil) from 0 °C to +70 °C |
| Frequency Response | –3 dB points | 5 Hz to 6,000 Hz (+0 / –3 dB) |
| Minimum Target Size | Diameter | 9.5 mm (0.375 in) |
| Maximum Lead-wire Length | Proximitor output (BNC) | 3 m (10 ft) |
| Hazardous Area Rating | Classification | Non-hazardous; suitable for Zone 2 / Division 2 systems with 28 V power supply |
Other Spare Parts
| Part Number | Description |
|---|---|
| 02173006 | Bulk cable (length specified in feet). 1.0 mm² (18 AWG), 2-conductor, twisted, shielded cable used for the 4 to 20 mA loop. Also used for the PROX OUT signal on the 990 Transmitter's terminal strip. |
| 123655 | 990 / 991 Transmitter System Installation User Guide. |
| 330153-05 | Cable Connector Kit. Package includes one set of 75 Ω miniature male and female connectors, shrink tubing, and a 3300 Isolator Seal for protection of coaxial connectors. |
| 163356 | Connector Crimp Tool Kit. Includes one set of 75 Ω ClickLoc inserts and connector installation instructions. Supplied with a carrying case. |
Key Advantage
Using input from the 3300 NSv proximity probe system, the 990 transmitter delivers stable peak-to-peak vibration measurements across a wide frequency range. The conditioned signal maintains accuracy within ±1.5% of full scale and remains stable over typical industrial temperature ranges. External, non-interacting zero and span adjustments allow precise field calibration without disrupting system wiring. Built-in current limiting and NOT OK signal behavior further enhance reliability, ensuring that control systems receive clear diagnostic information in the event of probe or signal issues.
Industrial Applications
The 990-04-50-02-00 transmitter is widely used by OEMs manufacturing centrifugal air compressors, process pumps, and auxiliary rotating equipment. In these machines, vibration data is often required for basic protection or condition indication rather than full diagnostic analysis. The transmitter provides a proportional vibration signal that can trigger alarms or shutdown logic in the customer's control system. This approach simplifies machine design while still offering effective vibration protection, making it ideal for packaged equipment delivered to a wide range of industrial facilities.
FAQ
01.What is the main purpose of the 990 Vibration Transmitter?
It converts vibration signals into a proportional 4–20 mA output for use in control and protection systems.
02.Is the transmitter loop powered?
03.Can it be connected directly to a PLC or DCS?
04.What is the typical frequency response range?
05.Is the 990 transmitter suitable for hazardous areas?
Recommendations
| 8114-4001 | 8333-4001 | 8222-4001 | 4PP120.0571-21 |
| 8164-4002 | 8108-4003 | KL2300A | X20BM11 |
| 8172-4003 | 8152-4002 | AB-7007-C | X20PS9400 |
| 8174-4002 | 8211-4307 | AB7065-C | X20DIF371 |
| 8178-4002 | 8313-4001 | AB7808-F | X20BT9100 |
| 8211-4303 | 8893-4502 | AB7697-F | 8V1016.00-2 |
| 8261-4154 | 9000-4001 | MAC-B343-GM60 | 80PS080X3.10-01 |
| 8261-4155 | 8143-4002 | PS-3306D-E | 5PC910.SX02-00 |
| 8263-4154 | 8163-4002 | GMSV36-01-D 91/096D/E | X20CP1586 |
| 8300-4003 | 8177-4002 | APROTB 223544 | 5PC810.SX01-00 |
Hot Tags: bently nevada 990-04-50-02-00 990 vibration transmitter, China bently nevada 990-04-50-02-00 990 vibration transmitter manufacturers, suppliers, 990 04 70 01 00 vibration transmitter, Bently Nevada 990 04 70 01 00, Bently Nevada 990 16 XX 01 CN, 990-16-XX-01-CN, 990 16 XX 01 CN Seismic sensor, 990-04-70-01-00