ABB IMASI03 Bailey Analog Input Slave Module

ABB IMASI03 Bailey Analog Input Slave Module

Dimensions:3.6x31x17.7cm
Weight: 0.64kg
Contact Sales Felicia for quotation and more info:
Mobile: +86 18030132586
Email: cn@mooreplc.com
Whatsapp(Wechat): +86 18030132586
Send Inquiry
Description
 

Products Description

 

 

   The ABB IMASI03 Bailey Analog Input Slave Module is a high-performance component designed for the INFI 90 process control system. Occupying a single slot in the Module Mounting Unit (MMU), this board conditions up to 16 analog input signals, offering programmable 16- to 24-bit resolution with independent channel configuration.

   The module filters, amplifies, and isolates incoming signals while providing advanced features such as channel isolation, open input detection, and automatic error compensation. Factory-calibrated with self-recalibration capabilities, it compensates for temperature drift and component aging without requiring user intervention.

   Hardware integration is streamlined through three card edge connectors: P1 for supply voltages, P2 for slave expander bus communication with the MFP, and P3 for field wiring via termination units. System addressing is configured through an onboard dipswitch, while jumpers define analog input signal types. This combination of flexibility, precision, and ease of installation makes the IMASI03 ideal for demanding industrial automation applications requiring reliable analog signal acquisition.

 

 

Contact Information

Our address

32D Guomao Building, No.388, Hubin south Road, Siming district, Xiamen, Fujian, China

Phone Number/Wechat/Whatsapp

+86 18030132586

E-mail

cn@mooreplc.com

product-800-520

 

 

Technical Parameters

 

 

Parameter Description / Value
Power Consumption  
+5 VDC Typical: 300 mA; Maximum: 450 mA
+15 VDC Typical: 130 mA; Maximum: 150 mA
−15 VDC Typical: 35 mA; Maximum: 50 mA
Analog Input Channels 16 independently configurable channels
Analog Input Types  
Thermocouples Type E, J, K, L, N (14 AWG), R, S, T, U; Chinese Type E and Chinese Type S
3-Wire RTD 100 Ω platinum (U.S. Laboratory Standard); 100 Ω platinum (U.S. Industrial Standard); 100 Ω platinum (European Standard); 120 Ω nickel; 10 Ω copper; Chinese 53 Ω copper
Millivolt −100 mV to +100 mV; 0 to 100 mV
High Level Voltage 1–5 VDC, 0–5 VDC, 0–10 VDC; −10 VDC to +10 VDC, or user-defined range within ±10 VDC
Current 4–20 mA, system-powered or externally powered
High Level Voltage Analog Accuracy  
4–20 mA Current Inputs Add 0.025% to high-level voltage analog error values
Ambient Operating Temperature 25 °C (standard conditions)
Power Supply Conditions Nominal supply values
Lead Wire Resistance Zero lead wire resistance
Full Scale Range (FSR) 20.0 V

 

 

Features

 

   

   The design of the IMASI03 module, as with all INFI 90 modules, allows for flexibility in creating a process management system. 

1. The IMASI03 conditions (filters, amplifies and isolates) up to 16 analog input signals.

2. The IMASI03 converts analog signals to digital values, adds compensation and corrections as needed, and provides digital values to the MFP through the slave expander bus.

3. Resolution of the analog-to-digital conversion process is programmable over a range from 16 to 24 bits.

4. Input type and channel resolution may be selected independently for each channel, permitting any mix of inputs on a single IMASI03 module.

5. Channel isolation and open input detection are provided for each channel.

6. Input circuit offset, gain and nonlinearity errors are recorded during a one time factory calibration procedure. These measurements provide error compensation during normal operation. The slave does automatic recalibration during normal operation to compensate for component aging and temperature drift. No user calibration is ever required.

 

 

Industrial Applications

 

 

   The IMASI03 is widely used in continuous process industries such as chemical processing, oil and gas, and power generation. In these environments, accurate measurement of temperature, pressure, flow, and other analog variables is critical. The module's support for multiple thermocouple types, RTDs, and current signals allows it to interface directly with a wide variety of field instruments.

   Its ability to collect high-quality analog data enables control systems to respond quickly and accurately to changing process conditions, improving safety and operational efficiency.

 

 

FAQ

 

01.How many analog input channels does the IMASI03 support?

The module supports 16 independently configurable analog input channels.

02.Which signal types can the IMASI03 accept?

It supports thermocouples, 3-wire RTDs, millivolt signals, voltage inputs, and 4–20 mA current inputs.

03.Does the IMASI03 support RTD inputs?

Yes, it supports multiple RTD standards, including platinum, nickel, and copper types.

04.Can the IMASI03 handle 4–20 mA current signals?

Yes, it supports both system-powered and externally powered 4–20 mA inputs.

05.What are the power requirements of the IMASI03?

It uses +5 VDC, +15 VDC, and −15 VDC supplies with defined typical and maximum current levels.
 

Recommendations

 

 

6FC5370-2AM03-0HA0 6ES7317-2EK14-0AB0 6SN2155-0AA10-1BA1
6FC5203-0AF02-0AA2 6EP1334-2AA00 6AU1400-1PA23-0AA0-Z=J00
6FC5370-0AA00-3AA1 6EP1334-2AA01 6SL3054-0EG00-1BA0
6AU1410-2AA0-0AA0 6ES7513-1AL01-0AB0 6ES7953-8LF30-0AA0
6AU1410-0AB00-0AA0 6ES7515-2FM01-0AB0 6SE7021-8TB61-Z =G93
6SL3040-0LA00-0AA1 7NG32120AN00 6SE7018-0TA61
6SN1121-0BA11-0AA0 6SL3350-6TK00-0EA0 6SE7021-3EB51
6SN1118-0DM33-0AA2 6ES7272-0AA30-0YA0 6SE7021-0EA61
6ES7400-1JA11-0AA0 6ES7272-0AA30-0YA1 6SE7024-7ED61
6SE7031-7HH84-1HJ0 6ES7272-1AA10-0YA0 6ES7361-3CA01-0AA0

 

Hot Tags: abb imasi03 bailey analog input slave module, China abb imasi03 bailey analog input slave module manufacturers, suppliers, IMMFP02 manual, ABB INNIS11, INNIS11 manual, abb bailey infi 90, INNIS11, INNIS11 ABB

Send Inquiry